Panasonic DMC-TZ4P / DMC-TZ4PC / DMC-TZ4PL / DMC-TZ4EB / DMC-TZ4EE / DMC-TZ4EF / DMC-TZ4EG / DMC-TZ4E / DMC-TZ11GC / DMC-TZ11GK / DMC-TZ11GN / DMC-TZ11GT / DMC-TZ11GJ Service Manual ▷ View online
25
Fig. D6
8.3.6.
Removal of the Sub P.C.B.
Fig. D7
8.3.7.
Removal of the Lens Unit
Fig. D8
26
8.3.8.
Removal of the Flash Unit, Battery
Case Unit, Battery Frame Unit,
Front Grip and Front Case
Case Unit, Battery Frame Unit,
Front Grip and Front Case
Fig. D9
Fig. D10
27
8.3.9.
Removal of the Battery Case Unit
Fig. D11
NOTE: (When Assembling)
Be sure to confirm the following points when assembling.
• The Screw is tightened enough.
• Assembling conditions are fine. (No distortion, no illegal-
• Assembling conditions are fine. (No distortion, no illegal-
space.)
• No dust and/or dirt on every Lens surfaces.
• LCD image is fine. (No dust and dirt on it, and no gradient
• LCD image is fine. (No dust and dirt on it, and no gradient
images.)
8.4.
Disassembly Procedure for the
Lens
Lens
NOTE: When Disassembling and Assembling for the Lens
1. To minimize the possibility of the CCD being dirt, perform
disassemble and/or assemble under the condition of the
CCD is being mounted.
Disassembling procedures for the CCD unit, refer to item
8.6.
CCD is being mounted.
Disassembling procedures for the CCD unit, refer to item
8.6.
2. Take care that the dust and dirt are not entered into the
lens.
In case of the dust is putted on the lens, blow off them by
airbrush.
In case of the dust is putted on the lens, blow off them by
airbrush.
3. Do not touch the surface of lens.
4. Use lens cleaning KIT (BK)(VFK1900BK).
5. Apply the grease to the point where is shown to" Grease
4. Use lens cleaning KIT (BK)(VFK1900BK).
5. Apply the grease to the point where is shown to" Grease
apply" in the figure.
8.4.1.
Removal of the Zoom Motor Unit
and Master Flange Unit
and Master Flange Unit
1. Unsolder (16 points).
2. Remove the libs (4 points).
3. Unscrew the 6 screws (A).
4. Remove the zoom motor unit.
5. Remove the master flange unit.
2. Remove the libs (4 points).
3. Unscrew the 6 screws (A).
4. Remove the zoom motor unit.
5. Remove the master flange unit.
28
8.4.2.
Removal of the Direct Frame, Both
Side Cam, 1st Lens Frame/2nd
Lens Frame/3rd Lens Frame, Pene-
tration Cam and Drive Frame
Side Cam, 1st Lens Frame/2nd
Lens Frame/3rd Lens Frame, Pene-
tration Cam and Drive Frame
• Push the penetration cam to the indicated by arrow from
lens side, and then remove the unit of direct frame, both side
cam, 1st lens frame/2nd lens frame/3rd lens frame, penetra-
tion cam and drive frame from the fixed frame unit.
cam, 1st lens frame/2nd lens frame/3rd lens frame, penetra-
tion cam and drive frame from the fixed frame unit.
8.4.3.
Removal of the Direct Frame, Both
Side Cam and 1st Lens Frame/2nd
Lens Frame/3rd Lens Frame
Side Cam and 1st Lens Frame/2nd
Lens Frame/3rd Lens Frame
1. Turn the drive frame, and then Align the groove of drive
frame and pin of 1st lens frame.
2. Push the 1st lens frame to the indicated by arrow from
lens side, and then remove the unit of direct frame, both
side cam and 1st lens frame/2nd lens frame/3rd lens
frame from the penetration cam and drive frame.
side cam and 1st lens frame/2nd lens frame/3rd lens
frame from the penetration cam and drive frame.
Click on the first or last page to see other DMC-TZ4P / DMC-TZ4PC / DMC-TZ4PL / DMC-TZ4EB / DMC-TZ4EE / DMC-TZ4EF / DMC-TZ4EG / DMC-TZ4E / DMC-TZ11GC / DMC-TZ11GK / DMC-TZ11GN / DMC-TZ11GT / DMC-TZ11GJ service manuals if exist.