DOWNLOAD Panasonic DMC-TZ4P / DMC-TZ4PC / DMC-TZ4PL / DMC-TZ4EB / DMC-TZ4EE / DMC-TZ4EF / DMC-TZ4EG / DMC-TZ4E / DMC-TZ11GC / DMC-TZ11GK / DMC-TZ11GN / DMC-TZ11GT / DMC-TZ11GJ Service Manual ↓ Size: 2.65 MB | Pages: 56 in PDF or view online for FREE

Model
DMC-TZ4P DMC-TZ4PC DMC-TZ4PL DMC-TZ4EB DMC-TZ4EE DMC-TZ4EF DMC-TZ4EG DMC-TZ4E DMC-TZ11GC DMC-TZ11GK DMC-TZ11GN DMC-TZ11GT DMC-TZ11GJ
Pages
56
Size
2.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-tz4p-dmc-tz4pc-dmc-tz4pl-dmc-tz4eb-dmc-tz4ee-d.pdf
Date

Panasonic DMC-TZ4P / DMC-TZ4PC / DMC-TZ4PL / DMC-TZ4EB / DMC-TZ4EE / DMC-TZ4EF / DMC-TZ4EG / DMC-TZ4E / DMC-TZ11GC / DMC-TZ11GK / DMC-TZ11GN / DMC-TZ11GT / DMC-TZ11GJ Service Manual ▷ View online

17
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4bits
Low 4 bits
Check point (Lower)
LENS
Lens drive
OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect error in OIS unit.
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect error in OIS unit.
OIS Unit
3000
GYRO (X) error. Gyro (IC7101: X axis) detect error on Main P.C.B..
IC7101 (Gyro element) or IC6001 (VENUS 4)
4000
GYRO (Y) error. Gyro (IC7101: Y axis) detect error on Main P.C.B..
IC7101 (Gyro element) or IC6001 (VENUS 4)
5000
MREF error (Reference voltage error).
IC9101 (LENS drive) or IC6001 (VENUS 4)
6000
Drive voltage (X) error.
VENUS 4 AD value error, LENS Unit, LENS flex breaks etc.
7000
Drive voltage (Y) error.
VENUS 4 AD value error, LENS Unit, LENS flex breaks etc.
C.B./Zoom
0010
HP Low detect error. (HP ENC. detects always low. (Fully retracted con-
nection.))
Zoom motor, ABS ENC., and/or circuit failure. Zoom deadlock (Exit 
side).
0020
HP Low detect error. (HP ENC. detects always high. (Exit connection.))
Zoom motor, ABS ENC., and/or circuit failure. Zoom deadlock (Retract 
side).
0030
0040
0050
Zoom ENC. detect error. (No signal is supplied from Encoder located on
Zoom Motor.)
Zoom motor, ABS ENC., and/or circuit failure Zoom deadlock.
Focus
0001
HP Low detect error (Focus encoder always Low detect error).
FP9001-(33) signal line or IC6001 (VENUS 4)
0002
HP High detect error (Focus encoder always High detect error).
FP9001-(41) signal line or IC6001 (VENUS 4)
Lens
18*1
0000
Power ON time out error.
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History
OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
HARD
VENUS A/D
Flash
28*0
0000
Flash charging error.
IC6001-(AC17) signal line or Flash charging circuit
FLASH ROM
(EEPROM 
Area)
FLASH ROM
(EEPROM 
Area)
2B*0
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
SYSTEM
RTC
2C*0
0001
SYSTEM IC initialize failure error
Communication between IC6001 (VENUS 4) and IC9101 (SYSTEM)
18
About “*” indication in the above table:
The third digit from the left is different as follows.
- In case of 0 (example: 18001000)
When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been 
completed.
It means that this error is occurred basically at user side.
- In case of 8 (example: 18801000)
When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been
released.
(Example; Factory assembling-line before unit shipment, Service mode etc.)
It means that this error is occurred at service side.
• 6. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
31*0
0001
Card logic error
SD memory card data line or IC6001 (VENUS 4)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 4)
0004
Write error
SD memory card data line or IC6001 (VENUS 4)
39*0
0005
Format error
CPU, ASIC 
hard
Stop
38*0
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 4)
0002
Camera task invalid code error.
IC6001 (VENUS 4)
0100
File time out error in recording motion image
IC6001 (VENUS 4)
0200
File data send error in recording motion image
IC6001 (VENUS 4)
0300
Single or burst recording brake time out.
Operation
Power on
3B*0
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C*0
0000
Imperfect zoom lens processing.
Zoom lens
35*0
0001
|
0007
Software error.
(0-7bit : command, 8-15bit : status)
35*1
0000
Though record preprocessing is necessary, it is not called.
35*2
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4bits
Low 4 bits
Check point (Lower)
19
7 Service Fixture & Tools
7.1.
Service Fixture and Tools
The following Service Fixture and tools are used for checking and servicing this unit.
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
Connection
Form
1
RFKZ0416
FP9001 (MAIN)  - LENS UNIT
41PIN 0.3 FFC
2
RFKZ0363
FP9002 (MAIN)  - TOP OPERATION UNIT
19PIN 0.5 FFC
3
RFKZ0354
FP9003 (MAIN)  - LCD UNIT
37PIN 0.3 FFC
4
RFKZ0445
PP9001 (MAIN)  - PS9801 (SUB)
100PIN B to B
5
VFK1951
FP9801 (SUB)   - CCD UNIT
39PIN 0.3 FFC
6
VFK1175
FP9802 (SUB)   - FP8001 (FLASH)
16PIN 0.5 FFC
7
VFK1974
FP9006 (MAIN)  - LCD UNIT
4PIN 0.5 FFC
20
7.3.1.
Extension Cable Connections
CAUTION-1. (When servicing FLASH PCB)
1. Be sure to discharge the capacitor on FLASH PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH PCB.