9
3 Service Navigation
3.1.
Introduction
This service manual contains technical information, which will allow service personnel's to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.
General Description About Lead Free Solder (PbF)
The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this
equipment in considering the globally environmental conservation.
The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin
(Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30 
°C (86 °F) more than that of the
normal solder.
Definition of PCB Lead Free Solder being used
Service caution for repair work using Lead Free Solder (PbF)
• The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
• (Definition: The letter of 
 is printed on the P.C.B. using the lead free solder.)
• To put lead free solder, it should be well molten and mixed with the original lead free solder.
• Remove the remaining lead free solder on the P.C.B. cleanly for soldering of the new IC.
• Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt the
lead free solder.
• Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30 degrees
C (662±86 
°F).
Recommended Lead Free Solder (Service Parts Route.)
• The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01KS-----------(0.3mm 100g Reel)
RFKZ06D01KS-----------(0.6mm 100g Reel)
RFKZ10D01KS-----------(1.0mm 100g Reel)
Note:
* Ingredient: tin (Sn) 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
3.3.
Important Notice 1:(Other than U.S.A. and Canadian Market) 
1. The service manual does not contain the following information because of the issue servicing to component level without nec-
essary equipment/facilities.
a. Schematic diagram, Block Diagram and PCB layout of MAIN P.C.B. 
b. Parts list for individual parts for MAIN P.C.B. 
When a part replacement is required for repairing MAIN P.C.B., replace as an assembled parts. (MAIN P.C.B.)
The letter of 
 is printed either foil side or components side on the P.C.B. using the lead free solder.
(See right figure)
10
3.4.
How to Define the Model Suffix (NTSC or PAL model)
There are six kinds of DMC-TZ18/ZS8, regardless of the colours. 
• a) DMC-ZS8P/PC 
• b) DMC-TZ18EB/EF/EG/EP 
• c) DMC-TZ18EE 
• d) DMC-TZ18GN 
• e) DMC-ZS8GK 
• f ) DMC-TZ18GC/PR, ZS8GH/PU
What is the difference is that the "INITIAL SETTINGS" data which is stored in Flash ROM mounted on Main P.C.B. 
3.4.1.
Defining methods
To define the model suffix to be serviced, refer to the nameplate which is putted on the bottom side of the Unit.
Note:
After replacing the MAIN P.C.B., be sure to achieve adjustment. 
The Maintenance software (DIAS) is available at "software download" on the "Support Information from NWBG/VDBG-AVC"
web-site in "TSN system". 
11
3.4.2.
INITIAL SETTINGS: 
After replacing the MAIN P.C.B., make sure to perform the initial settings after achieving the adjustment by ordering the following
procedure in accordance with model suffix of the unit.
1. IMPORTANT NOTICE:
Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES:
• Precautions: Read the above "CAUTION 1" and "CAUTION 2", carefully.
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
2. Set the mode dial to the PROGRAM AE mode. 
Note: If the mode dial position is other than PROGRAM AE mode, it does not display the initial settings menu.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
Set the REC/PLAYBACK selector switch to "REC (Camera mark)".
While keep pressing "UP of Cursor button" and E. ZOOM button simultaneously, turn the Power on.
• Step 2. The cancellation of "INITIAL SETTINGS":
Set the REC/PLAYBACK selector switch to "PLAYBACK".
Press "UP of Cursor button" and E. ZOOM button simultaneously, then turn the Power off.
• Step 3. Turn the Power on:
Set the REC/PLAYBACK selector switch to "REC (Camera mark)", and then turn the Power on.
• Step 4. Display the "INITIAL SETTINGS" menu:
       Note: If the unit is other than PROGRAM AE mode, it does not display the initial settings menu.
While keep pressing MENU/SET and "RIGHT of Cursor button" simultaneously, turn the Power off.
The "INITIAL SETTINGS" menu is displayed.
There are two kinds of "INITIAL SETTINGS" menu form as follows:
[CASE 1. After replacing MAIN P.C.B.]
When MAIN P.C.B. has just been replaced, all of the model suffix are displayed as follows. (Five pages in total)
12
[CASE 2. Other than "After replacing MAIN P.C.B."]
• Step 5. Chose the model suffix in "INITIAL SETTINGS": (Refer to "CAUTION 1")
[Caution: After replacing MAIN P.C.B.]
(Especially, other than "EG, EF, EB and EP" models).
The model suffix can be chosen, JUST ONE TIME.             
Once one of the model suffix have been chosen, the model suffix lists will not be displayed, thus, it can be changed.             
Therefore, select the area carefully.             
Select the area with pressing "UP / DOWN of Cursor buttons".
• Step 6. Set the model suffix at "INITIAL SETTINGS":
Press the "RIGHT of Cursor buttons". 
The only set area is displayed. Press the "RIGHT of Cursor buttons" after confirmation.
(The unit is powered off automatically.)
• Step 7. CONFIRMATION:
Confirm the display of "PLEASE SET THE CLOCK" in concerned language when the unit is turned on again. 
When the unit is connected to PC with USB cable, it is detected as removable media.
1) As for your reference, major default setting condition is as shown in the following table.
    Default setting (After "INITIAL SETTINGS") 
MODEL
VIDEO OUTPUT
LANGUAGE
DATE
REMARKS
a)
DMC-TZ18EB
PAL
English
Date/Month/Year
b)
DMC-TZ18EE
PAL
Russian
Date/Month/Year
c)
DMC-TZ18EF
PAL
French
Date/Month/Year
d)
DMC-TZ18EG
PAL
English
Date/Month/Year
e)
DMC-TZ18EP
PAL
English
Date/Month/Year
f)
DMC-TZ18GC
PAL
English
Date/Month/Year
g)
DMC-TZ18GN
PAL
English
Date/Month/Year
h)
DMC-TZ18PR
NTSC
Spanish
Month/Date/Year
i)
DMC-ZS8GH
PAL
English
Date/Month/Year
j)
DMC-ZS8GK
PAL
Chinese (simplified)
Year/Month/Date
k)
DMC-ZS8P
NTSC
English
Month/Date/Year
l)
DMC-ZS8PC
NTSC
English
Month/Date/Year
m)
DMC-ZS8PU
NTSC
Spanish
Month/Date/Year
Page of 74
Display

Click on the first or last page to see other DMC-TZ18EB / DMC-TZ18EE / DMC-TZ18EF / DMC-TZ18EG / DMC-TZ18EP / DMC-TZ18GC / DMC-TZ18GN / DMC-TZ18PR / DMC-ZS8P / DMC-ZS8PC / DMC-ZS8PU / DMC-ZS8GH / DMC-ZS8GK service manuals if exist.