DOWNLOAD Panasonic DMC-TZ18EB / DMC-TZ18EE / DMC-TZ18EF / DMC-TZ18EG / DMC-TZ18EP / DMC-TZ18GC / DMC-TZ18GN / DMC-TZ18PR / DMC-ZS8P / DMC-ZS8PC / DMC-ZS8PU / DMC-ZS8GH / DMC-ZS8GK Service Manual ↓ Size: 4.57 MB | Pages: 74 in PDF or view online for FREE

Model
DMC-TZ18EB DMC-TZ18EE DMC-TZ18EF DMC-TZ18EG DMC-TZ18EP DMC-TZ18GC DMC-TZ18GN DMC-TZ18PR DMC-ZS8P DMC-ZS8PC DMC-ZS8PU DMC-ZS8GH DMC-ZS8GK
Pages
74
Size
4.57 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-tz18eb-dmc-tz18ee-dmc-tz18ef-dmc-tz18eg-dmc-tz.pdf
Date

Panasonic DMC-TZ18EB / DMC-TZ18EE / DMC-TZ18EF / DMC-TZ18EG / DMC-TZ18EP / DMC-TZ18GC / DMC-TZ18GN / DMC-TZ18PR / DMC-ZS8P / DMC-ZS8PC / DMC-ZS8PU / DMC-ZS8GH / DMC-ZS8GK Service Manual ▷ View online

17
6 Service Mode
6.1.
Error Code Memory Function
1. General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the                   
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery,
the battery is pulled out) The error code is memorized to FLASH ROM when the unit has just before powered off.
2. How to display
The error code can be displayed by ordering the following procedure:
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
2. Set the mode dial to the PROGRAM AE mode.
Note: 
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
Set the REC/PLAYBACK selector switch to "REC (Camera mark)".
While keep pressing "UP of Cursor button" and E. ZOOM button simultaneously, turn the Power on.
• Step 2. Execute the error code display mode:
Press the "LEFT of Cursor button", MENU/SET button and E. ZOOM button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display 
→ Error code display → Operation history display → Normal display → .....
18
3. Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect
error in OIS unit.
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect
error in OIS unit.
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7103) detect error on Top
Operation P.C.B.
GYRO X
GYRO NG
IC7103 (Gyro element) or IC6001 (VENUS 6)
4000
GYRO (Y) error. Gyro (IC9701) detect error on Gyro
P.C.B.
GYRO Y
IC9701 (Gyro element) or IC6001 (VENUS 6)
5000
MREF error (Reference voltage error).
OIS REF
LENSSd/DSP 
NG
IC9101 (LENS drive) or IC6001 (VENUS 6)
6000
Drive voltage (X) error.
OISX REF
LENSu/LENS 
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS 6) AD
value error, etc.
7000
Drive voltage (Y) error.
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS 6) AD
value error, etc.
Zoom
(C.B.)
0?10
Collapsible barrel Low detect error
ZOOM L
ZOOMm/
LENSu
(Collapsible barrel encoder always detects High.)
Mechanical lock, FP9005-(29) signal line or IC6001
(VENUS 6)
0?20
Collapsible barrel High detect error
ZOOM H
(Collapsible barrel encoder always detects Low.)
Mechanical lock, FP9005-(29) signal line or IC6001
(VENUS 6)
0?30
Zoom motor sensor error.
ZOOM ENC
Mechanical lock, FP9005-(40), (42) signal line or
IC6001 (VENUS 6)
0?40
Zoom motor sensor error. (During monitor mode.)
Mechanical lock, FP9005-(40), (42) signal line or
IC6001 (VENUS 6)
0?50
Zoom motor sensor error. (During monitor mode with
slow speed.)
Mechanical lock, FP9005-(40), (42) signal line or
IC6001 (VENUS 6)
0?60
Phase error or operation failure of zoom Lens/motor/
encoder. (IMPACT)
Mechanical lock, zoom encoder.
Focus
0?01
HP High detect error
(Focus encoder always detects High, and not
becomes Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9005-(29) signal line or IC6001
(VENUS 6)
0?02
HP Low detect error
(Focus encoder always detects Low, and not
becomes High)
FOCUS H
Mechanical lock, FP9005-(29) signal line or IC6001
(VENUS 6)
Lens
18*1
0000
Power ON time out error.
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
19
Adj.History OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
OIS ADJ
OIS ADJ
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
HARD
VENUS
A/D
Flash
28*0
0000
Flash charging error.
STRB CHG
STRB PCB/
FPC
IC6001-(AC18) signal line or Flash charging circuit
FLASH
ROM
(EEPROM
Area)
FLASH
ROM
(EEPROM
Area)
2B*0
0001
0003
0004
EEPROM read error
FROM RE
FROM
IC6002 (FLASH ROM)
0002
EEPROM write error
FROM WR
FROM
IC6002 (FLASH ROM)
0005
Firmware version up error
(No indication) (No indication)
Replace the firmware file in the SD memory card.
0008
0009
SDRAM error
SDRAM Mounting defective
SYSTEM
RTC
2C*0
0001
SYSTEM IC initialize failure error
SYS INIT
MAIN PCB
Communication between IC6001 (VENUS 6) and
IC9101 (SYSTEM)
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
NMI RST
MAIN PCB
Card
Card
31*0
0001
Card logic error
SD CARD
SD CARD/
DSP
SD memory card data line or IC6001 (VENUS 6)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 6)
0004
Write error
SD WRITE
SD memory card data line or IC6001 (VENUS 6)
39*0
0005
Format error
INMEMORY
FROM
CPU,
Stop
38*0
0001
Camera task finish process time out.
LENS COM
LENSu/DSP
ASIC hard
Communication between Lens system and IC6001
(VENUS 6)
0002
Camera task invalid code error.
DSP
DSP
IC6001 (VENUS 6)
0100
File time out error in recording motion image
IC6001 (VENUS 6)
0200
File data cue send error in recording motion image
IC6001 (VENUS 6)
0300
Single or burst recording brake time out.
Memory
area
3A*0
0008
 work area partitioning failure
(No indication) (No indication)
USB dynamic memory securing failure when con-
necting
Operation
Power on
3B*0
0000
FLASH ROM processing early period of camera dur-
ing movement.
INIT
(No indication)
Zoom
Zoom
3C*0
0000
Imperfect zoom lens processing
ZOOM
ZOOMm/
LENSu
Zoom lens
35*0
0000
|
FFFF
Software error
(0-7bit : command, 8-15bit : status)
DSP
DSP
35*1
0000
Though record preprocessing is necessary, it is not
called.
35*2
0000
Though record preprocessing is necessary, it is not
completed.
(No indication) (No indication)
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
20
Important notice about "Error Code List"
1) About "*" indication:
The third digit from the left is different as follows.
+.In case of 0 (example: 18 0 01000)
  When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been completed.                 
  It means that this error is occurred basically at user side.
+.In case of 8 (example: 18 8 01000)
  When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been released.                 
  (Example; Factory assembling-line before unit shipment, Service mode etc.)                 
  It means that this error is occurred at service side.
2) About "?" indication: ("18*0 0?01" to "18*0 0?50"):                 
 The third digit from the right shows one of the hexadecimal ("0" to "F") character.
4. How to exit from Error Code display mode:
Simply, turn the power off. (Since Error code display mode is executed under the condition of temporary cancellation of "INITIAL
SETTINGS", it wake up with normal condition when turn off the power.)
Note:
The error code can not be initialized.
Page of 74
Display

Click on the first or last page to see other DMC-TZ18EB / DMC-TZ18EE / DMC-TZ18EF / DMC-TZ18EG / DMC-TZ18EP / DMC-TZ18GC / DMC-TZ18GN / DMC-TZ18PR / DMC-ZS8P / DMC-ZS8PC / DMC-ZS8PU / DMC-ZS8GH / DMC-ZS8GK service manuals if exist.