1.4.2. INITIAL SETTINGS:
When you replace the Main C.B.A. be sure to perform the initial settings after achieving the Adjustment, by ordering the following
procedure in accordance with model suffix.
    
·
    
Step 1. The temporary cancellation of factory setting:
Set the mode dial to “ Normal Picture
(Red camera mark)”.
While keep pressing Burst
and “ UP
of Cross key” simultaneously, turn the Power on.
    
·
    
Step 2. The cancellation of factory setting:
Set the mode dial to “ Playback
”.
While keep pressing Burst
and “ UP
of Cross key” simultaneously, turn the Power off.
    
·
    
Step 3. Turn the Power on:
Set the mode dial to “ Normal Picture
(Red camera mark)”, and then turn the Power on.
    
·
    
Step 4. Display the INITIAL SETTING:
While keep pressing MENU
and “ RIGHT
of Cross key” simultaneously, turn the Power off.
    
·
    
Step 5. Set the INITIAL SETTING:
Select the area with pressing “ UP
/ DOWN
of Cross key”, and then press the “ RIGHT
of Cross key”.
Confirm the display of “SET THE CLOCK” in English when the unit is turned on again.
    
·
    
Step 6. CONFIRMATION:
The display shows “SET THE CLOCK” when turn the Power on again.
Connect the unit to PC with USB cable and is detected as removable media.
5
DMC-LC43PP / DMC-LC43PM / DMC-LC43E / DMC-LC43B / DMC-LC43A / DMC-LC43EN / DMC-LC43KR
2 SAFETY PRECAUTIONS
2.1. GENERAL GUIDELINES
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that
these
critical
parts
should
be
replaced
with
manufacturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
 2. An Isolation Transformer should always be used during the
servicing of AC Adaptor whose chassis is not isolated from
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
 3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
 5. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
2.2. LEAKAGE CURRENT COLD
CHECK
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
 2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between 1
M
and 5.2 M
. When the exposed metal does not have a
return path to the chassis, the reading must be infinity.
2.3. LEAKAGE CURRENT HOT
CHECK (See Figure 1.)
 1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
 2. Connect a 1.5 k
, 10 W resistor, in parallel with a 0.15 µF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
 3. Use an AC voltmeter, with 1 k
/V or more sensitivity, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
6
DMC-LC43PP / DMC-LC43PM / DMC-LC43E / DMC-LC43B / DMC-LC43A / DMC-LC43EN / DMC-LC43KR
3 PREVENTION OF ELECTRO STATIC DISCHARGE (ESD)
TO ELECTROSTATICALLY SENSITIVE (ES) DEVICES
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
 4. Use only an antistatic solder removal device. Some solder removal devices not classified as "antistatic (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
 5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION :
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD)
sufficient to damage an ES device).
7
DMC-LC43PP / DMC-LC43PM / DMC-LC43E / DMC-LC43B / DMC-LC43A / DMC-LC43EN / DMC-LC43KR
4 HOW TO REPLACE THE LITHIUM BATTERY
4.1. REPLACEMENT PROCEDURE
 1. Remove the MAIN C.B.A. (Refer to Disassembly Procedures.)
 2. Remove the Lithium battery (Ref. No. “Z9101” at component side of MAIN C.B.A.) and then replace it into new one.
NOTE:
This Lithium battery is a critical component. (Type No.: ML614S Manufactured by Seiko Instruments Inc.)
It must never be subjected to excessive heat or discharge.
It must therefore only be fitted in requirement designed specifically for its use.
Replacement batteries must be of same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
8
DMC-LC43PP / DMC-LC43PM / DMC-LC43E / DMC-LC43B / DMC-LC43A / DMC-LC43EN / DMC-LC43KR
Page of 42
Display

Click on the first or last page to see other DMC-LC43PP / DMC-LC43PM / DMC-LC43E / DMC-LC43B / DMC-LC43A / DMC-LC43EN / DMC-LC43KR (serv.man2) service manuals if exist.