Panasonic DMC-FT2EB / DMC-FT2EE / DMC-FT2EF / DMC-FT2EG / DMC-FT2EP / DMC-FT2GC / DMC-FT2GN / DMC-FT2SG / DMC-TS2P / DMC-TS2PC / DMC-TS2PU / DMC-TS2GH / DMC-TS2GD / DMC-TS2GT Service Manual ▷ View online

9
3 Service Navigation
3.1.
Introduction
This service manual contains technical information, which will allow service personnel's to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.
Air-leak test (inspection)
[About Waterproof/Dustproof]
• This camera’s waterproof/dustproof rating complies with the "IPX8" and "IP6X" ratings.
• This camera can operate underwater, to a depth not exceeding 10 m (33 feet) for a time not exceeding 60 minutes.*1
*1 This means that the camera can be used underwater for a specified time in specified pressure in accordance with the 
 handling method established by Panasonic.
 This does not guarantee no destruction, no malfunction, or waterproofing in all conditions.
[About Shockproof]
• This camera also complies with "MIL-STD 810F (Method 516.5-Shock)".
The camera has cleared a drop test from a height of 2 m (6.6 feet) onto 3 cm (0.10 feet) thick plywood.
In most cases this camera should not sustain any damage if dropped from a height not exceeding 2 m (6.6 feet).*2
*2 This does not guarantee no destruction, no malfunction, or waterproofing in all conditions.
• Due to the above characteristics of the products, perform the air-leak test (inspection) using Air -leak tester (Part No.:RFKZ0528)
before/after servicing including assembly and/or assembly process.
Note:
The purpose of the air-leak test before servicing is that whether the malfunction occurred due to air-leak or not.
• When servicing, refer to the "7.Troubleshooting" section for details.
3.3.
Replacing the waterproof packing (waterproof seal)
• The integrity of the waterproof packing may decrease about 1 year, with use and age.
(We recommend end users to replace the waterproof packing (waterproof seal) at least once each year described in the operat-
ing instructions.)
• As for replacement procedure, refer to the 7.1.2. Periodical maintenance (Packing replacement) flow for details.
3.4.
Front case Unit
• Due to keep worterproof performance retention, the replacement part size of the front case unit for this model is including the Top
Operation P.C.B., Speaker, Microphone and so on, and not replaceable, individually.
Confirm the replacement part list and exploded views for details.
3.5.
Lens Unit
• Since the lens unit for this model is assembled with high accuracy manufacturing technologies, it is not allowed to disassemble/
assemble the lens unit, in terms of performance retention.
When servicing, it has to be handled the "Lens with CCD unit" as the smallest part size.
Confirm the replacement part list and exploded views for details.
10
3.6.
General Description About Lead Free Solder (PbF)
The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this
equipment in considering the globally environmental conservation.
The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin
(Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30 
°C (86 °F) more than that of the
normal solder.
Definition of P.C.B. Lead Free Solder being used
Service caution for repair work using Lead Free Solder (PbF)
• The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
• (Definition: The letter of 
 is printed on the P.C.B. using the lead free solder.)
• To put lead free solder, it should be well molten and mixed with the original lead free solder.
• Remove the remaining lead free solder on the P.C.B. cleanly for soldering of the new IC.
• Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt the
lead free solder.
• Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30 degrees
C (662±86 
°F).
Recommended Lead Free Solder (Service Parts Route.)
• The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01KS-----------(0.3mm 100g Reel)
RFKZ06D01KS-----------(0.6mm 100g Reel)
RFKZ10D01KS-----------(1.0mm 100g Reel)
Note
* Ingredient: tin (Sn) 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
3.7.
Important Notice 1:(Other than U.S.A. and Canadian Market) 
1. The service manual does not contain the following information, because of the impossibility of servicing at component level
without concerned equipment/facilities.
a. Schematic diagram, Block Diagram and P.C.B. layout of MAIN P.C.B. 
b. Parts list for individual parts for MAIN P.C.B.
When a part replacement is required for repairing MAIN P.C.B., replace as an assembled parts. (MAIN P.C.B.)
2. The following category is/are recycle module part. please send it/them to Central Repair Center. 
• MAIN P.C.B. (VEP56096B) : For EB, EF, EG, EP.
• MAIN P.C.B. (VEP56096A) : For EE, GC, GN, GH, GT, GD, P, PC, PU, SG.
The letter of 
 is printed either foil side or components side on the P.C.B. using the lead free solder.
(See right figure)
11
3.8.
How to Define the Model Suffix (NTSC or PAL model)
There are eight kinds of DMC-FT2/TS2, regardless of the colours. 
• a) DMC-FT2 (Japan domestic model.)/SG 
• b) DMC-TS2P/PC 
• c) DMC-FT2EB/EF/EG/EP 
• d) DMC-FT2EE 
• e) DMC-TS2GT 
• f ) DMC-FT2GN
• g) DMC-TS2GD 
• h) DMC-FT2GC, DMC-TS2GH/PU 
What is the difference is that the “INITIAL SETTINGS” data which is stored in Flash ROM mounted on Main P.C.B. 
3.8.1.
Defining methods
To define the model suffix to be serviced, refer to the nameplate which is putted on the bottom side of the Unit.
Note:
After replacing the MAIN P.C.B., be sure to achieve adjustment. 
The Maintenance software (DIAS) is available at “software download” on the “Support Information from NWBG/VDBG-AVC”
web-site in “TSN system”. 
12
3.8.2.
INITIAL SETTINGS: 
After replacing the MAIN P.C.B., be sure to perform the initial settings after achieving the adjustment by ordering the following pro-
cedure in accordance with model suffix of the unit. 
1. IMPORTANT NOTICE:
Before proceeding Initial settings, be sure to read the following CAUTIONS. 
2. PROCEDURES:
• Precautions: Read the above "CAUTION 1" and "CAUTION 2", carefully
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
2. Set the mode dial to the NORMAL PICTURE mode.
Note:
If the mode dial position is other than NORMAL PICTURE mode, it does not display the initial settings menu.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
While keep pressing “UP of Cursor button” and DISPLAY button simultaneously, turn the Power on.
• Step 2. The cancellation of "INITIAL SETTINGS":
Press the PLAYBACK button.
Press "UP of Cursor button" and DISPLAY button simultaneously, then turn the Power off.
• Step 3. Turn the Power on:
Turn the Power on.
• Step 4. Display the "INITIAL SETTINGS" menu:
Note:
If the unit is other than NORMAL PICTURE mode, it does not display the initial settings menu.
While keep pressing MENU/SET and "RIGHT of Cursor button" simultaneously, turn the Power off.
The "INITIAL SETTINGS" menu is displayed.
There are two kinds of “NITIAL SETTINGS” menu form as follows:
[CASE 1. After replacing MAIN P.C.B.]
[Except "EG, EF, EB and EP" models : (VEP56096A is used as a Main P.C.B.)]
When MAIN P.C.B. has just been replaced, the following model suffix list is displayed as follows. (Three pages in total)