2 SAFETY PRECAUTIONS
2.1. GENERAL GUIDELINES
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that
these
critical
parts
should
be
replaced
with
manufacturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
 2. An Isolation Transformer should always be used during the
servicing of AC Adaptor whose chassis is not isolated from
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
 3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
 5. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
2.2. LEAKAGE CURRENT COLD
CHECK
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
 2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between 1
M
and 5.2 M
. When the exposed metal does not have a
return path to the chassis, the reading must be infinity.
2.3. LEAKAGE CURRENT HOT
CHECK (See Figure 1.)
 1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
 2. Connect a 1.5 k
, 10 W resistor, in parallel with a 0.15 µF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
 3. Use an AC voltmeter, with 1 k
/V or more sensitivity, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
Figure. 1
6
DMC-F1PP / DMC-F1PM / DMC-F1E / DMC-F1B / DMC-F1A / DMC-F1EN / DMC-F1T / DMC-F1KR
3 PREVENTION OF ELECTRO STATIC DISCHARGE (ESD)
TO ELECTROSTATICALLY SENSITIVE (ES) DEVICES
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
 4. Use only an antistatic solder removal device. Some solder removal devices not classified as "antistatic (ESD protected)" can
generate electrical charge sufficient to damage ES devices.
 5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION :
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD)
sufficient to damage an ES device).
4 HOW TO RECYCLE THE LITHIUM ION BATTERY
(U.S. ONLY)
7
DMC-F1PP / DMC-F1PM / DMC-F1E / DMC-F1B / DMC-F1A / DMC-F1EN / DMC-F1T / DMC-F1KR
5 CAUTION FOR AC CORD
(VJA0940 TYPE) (B only)
5.1. INFORMATION FOR YOUR
SAFETY
IMPORTANT
Your attention is drawn to the fact that recording of pre-
recorded tapes or discs or other published or broadcast
material may infringe copyright laws.
WARNING
To reduce the risk of fire or shock hazard, do not expose
this equipment to rain or moisture.
CAUTION
To reduce the risk of fire or shock hazard and annoying
interference, use the recommended accessories only.
FOR YOUR SAFETY
DO NOT REMOVE THE OUTER COVER
To prevent electric shock, do not remove the cover. No user
serviceable parts inside. Refer servicing to qualified service
personnel.
5.2. CAUTION FOR AC MAINS
LEAD
For your safety, please read the following text carefully.
This appliance is supplied with a moulded three-pin mains plug
for your safety and convenience.
A 5-ampere fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the
replacement fuse has a rating of 5 amperes and it is approved
by ASTA or BSI to BS1362
Check for the ASRA mark or the BSI mark on the body of the
fuse.
If the plug contains a removable fuse cover you must ensure
that it is refitted when the fuse is replaced.
If you lose the fuse cover, the plug must not be used until a
replacement cover is obtained.
A replacement fuse cover can be purchased from your local
Panasonic Dealer.
If the fitted moulded plug is unsuitable for the socket outlet in
your home then the fuse should be removed and the plug cut
off and disposed of safety.
There is a danger of severe electrical shock if the cut off plug
is inserted into any 13-ampere socket.
If a new plug is to be fitted please observe the wiring code as
shown below.
If in any doubt, please consult a qualified electrician.
5.2.1. Important
The wires in this mains lead are coloured in accordance with
the following code:
Blue
Neutral
Brown
Live
As the colours of the wires in the mains lead of this appliance
may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured BLUE must be connected to the
terminal in the plug which is marked with the letter N or
coloured BLACK.
The wire which is coloured BROWN must be connected to the
terminal in the plug which is marked with the letter L or coloured
RED.
Under no circumstances should either of these wires be
connected to the earth terminal of the three pin plug, marked
with the letter E or the Earth Symbol.
5.2.2. Before use
remove the Connector Cover as follows.
5.2.3. How to replace the Fuse
 1. Remove the Fuse Cover with a screwdriver.
 2. Replace the fuse and attach the Fuse cover.
8
DMC-F1PP / DMC-F1PM / DMC-F1E / DMC-F1B / DMC-F1A / DMC-F1EN / DMC-F1T / DMC-F1KR
6 HOW TO REPLACE THE LITHIUM BATTERY
6.1. REPLACEMENT PROCEDURE
 1. Remove the MAIN C.B.A. (Refer to Disassembly Procedures.)
 2. Remove the Lithium battery (Ref. No. “Z9101” at component side of MAIN C.B.A.) and then replace it into new one.
NOTE:
This Lithium battery is a critical component. (Type No.: ML614S Manufactured by Matsushita Battery Industrial Co.,Ltd.)
It must never be subjected to excessive heat or discharge.
It must therefore only be fitted in requirement designed specifically for its use.
Replacement batteries must be of same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
9
DMC-F1PP / DMC-F1PM / DMC-F1E / DMC-F1B / DMC-F1A / DMC-F1EN / DMC-F1T / DMC-F1KR
Page of 44
Display

Click on the first or last page to see other DMC-F1PP / DMC-F1PM / DMC-F1E / DMC-F1B / DMC-F1A / DMC-F1EN / DMC-F1T / DMC-F1KR (serv.man2) service manuals if exist.