Panasonic SC-HC35EG / SC-HC35EF / SC-HC35EP Service Manual ▷ View online
21
6.3.3.
Doctor Mode Table 3
Version Display
(DEC)
(DEC)
Check sum
(HEX)
(HEX)
Item
FL Display
Key Operation
Mode Name
Description
Front Key
Cold Start
The [NO DISC] display will appear after 3s,
EEPROM not detected only firmware is display
To display result of self
adjustment for CD.
adjustment for CD.
The [NO DISC] display will appear after 3s,
In Doctor Mode:
Press [
Press [
] follow by [1] & then [4]
button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
In Doctor Mode:
Press [
Press [
] follow by [1] & then [5]
button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
In Doctor Mode:
Press [SLEEP] button on remote
control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
Press [SLEEP] button on remote
control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
In Doctor Mode:
Press [
Press [
] follow by [2] & then [2]
button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
CD Self-Adjusment
Display
Display
CD Combination Test
To check the open/close
operation & inner outer disc
access operation.
1. It fails when CD
open/close is not completed
by 4s.
2. The disc access fails in
10s.
3. The traverse is out of
focus for more than 2s.
operation & inner outer disc
access operation.
1. It fails when CD
open/close is not completed
by 4s.
2. The disc access fails in
10s.
3. The traverse is out of
focus for more than 2s.
Refer to
6.3.7 for more
information
To activate cold start upon
next power up.
(Backup data are initialized)
next power up.
(Backup data are initialized)
EEPROM Checksum
To check sum of EEPROM
for a simplifield ROM
correction.
1. When EEPROM is not
detected, the only micro-p’s
version shall be displayed
without an EEPROM’s
check sum
for a simplifield ROM
correction.
1. When EEPROM is not
detected, the only micro-p’s
version shall be displayed
without an EEPROM’s
check sum
Auto Power down
Detect (APD) Test
Detect (APD) Test
To check for the auto power
down operation
down operation
Condition 1 (when APD is OK)
Condition 2 (when APD is abnormal operation)
In any mode:
Press
Press
[ ]
button on main unit follow by
[4] & then [7] on remote control.
22
6.3.4.
Doctor Mode Table 4
6.3.5.
Mecha Sliding Panel Reliability
Item
FL Display
Key Operation
Mode Name
Description
Front Key
In Doctor Mode:
Press [
Press [
] follow by [1] & then [6]
button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
In Doctor Mode:
Press [4] button on remote control.
Press [4] button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
Region Setting Check
To check Region setting of
unit.
unit.
Refer to 6.3.8 for the
Region
Setting destination
Region Setting destination
CD LSI Version No
Check
Check
To check CD LSI Version
No. & checksum correction
No. & checksum correction
Model setting
To check Model Setting.
Refer to 6.3.9 for the Model
Setting
Setting
Version (decimal)
Checksum (hex)
In Doctor Mode:
Press [
Press [
] follow by [1] & then [8]
button on remote control.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To cancel, press [0] button on remote
control. It returns Doctor Mode.
To exit Doctor Mode, press
but-
ton on main unit or remote control.
Model Setting
23
6.3.6.
CD Traverse Test (For CD)
6.3.7.
CD Reliability Test (For CD)
24
6.3.8.
Region Check Table (For Tuner)
6.3.9.
Model setting
Region
Model
Series
Country
1
HC35
P/PC
North America
2
HC35
Japan
Japan
3
HC35
EP
E. Europe
4
HC35
EB/EG/EF
UK, Germany, France
5
HC35
DBEB
UK
6
HC35
PX
Global
7
HC35
GA/GT/GK/GS
S.E. Asia
8
HC35
GN
Oceania
9
HC35
DBGN
Oceania
Region No.
Function
Model
With iPod
With Shock Proof
S0
O
O
HC35
Click on the first or last page to see other SC-HC35EG / SC-HC35EF / SC-HC35EP service manuals if exist.