Panasonic SA-XH70GW / SA-XH70EE / SC-XH70EE Service Manual ▷ View online
37
9.6.2.
Process Flow (2/2)
FL/ GUI Display
Remarks
Item
Description
Process
FL Display 1.6:
FL Display (Main Unit) will
display "GOOD" as
"FL Display 1.6" shown.
display "GOOD" as
"FL Display 1.6" shown.
To initialize, press and hold
main unit [OPEN/CLOSE]
then press remote control
key [ 10].
main unit [OPEN/CLOSE]
then press remote control
key [ 10].
Update Completed
If firmware software update
completes successfully:
completes successfully:
GUI Display 1.3:
"Firmware update is completed,
please open the tray and
remove the disc."
please open the tray and
remove the disc."
GUI Display 1.3:
Step 5
Eject the disc and power off main
unit.
Eject the disc and power off main
unit.
Step 6
Power on the unit and do system
initialize.
Power on the unit and do system
initialize.
Step 7
Update process finish.
38
10 Troubleshooting Guide
10.1. Troubleshooting Guide for F61 and/or F76
This section illustrates the checking procedures when upon detecting the error of “F61” and/or “F76” after power up of the unit. It is
for purpose of troubleshooting and checking in SMPS P.C.B..
for purpose of troubleshooting and checking in SMPS P.C.B..
Symptom(s)
Checking items
Possible Fault(s)
Remarks
Set cannot Power ON:
Condition 1: With
Standby LED on
Standby LED on
1
2
1
Solder crack,dry joint ,short
circuit,open circuit,etc
circuit,open circuit,etc
AC cord
AC Inlet P5701
1 Faulty AC cord, loose
connection
2
2
Solder crack,dry joint ,short
circuit,open circuit,etc
circuit,open circuit,etc
2
P5701 solder crack, dry joint
etc
etc
Faulty IC2900 (No +12V
output)
output)
Set can Power ON
then F61
then F61
Set can Power ON
then F76
then F76
Set can Power ON
working normally for
sometime then F61
working normally for
sometime then F61
Condition 2: With
Standby LED Off or
flickering
Standby LED Off or
flickering
3
1
3 F1 Fuse open
Fuse F1
DC-DC circuit
1 Thermal Diode D5706
2 Photocoupler PC701
1 Transformer T5701
2 Photocoupler PC701
1a Pin 14/15 shorted to pin 12/13
1b Fan unit defective
1a Loose connection at CN100
(No +23V), check cable
connection between CN100 &
H2016.
connection between CN100 &
H2016.
1b No +6V voltage output at pin3,
IC106.
1d Q100 faulty (No +5V voltage
output at pin1,2,5 & 6).
1e Q107 & D114 faulty (No +9V
voltage).
1c L125 open circuit.
1a
1b
Improper contact between
D5706 to heatsink
OTP (thermal) protection
trigger prematurely
D5706 to heatsink
OTP (thermal) protection
trigger prematurely
1f IC107 faulty (No +3.3V voltage
output at pin1).
1g K102, K105, K304 open circuit
(+3.3V line going to Panel
P.C.B. at CN203).
P.C.B. at CN203).
1) Refer to Fig. 1. SMPS P.C.B.
Refer to Fig. 1. SMPS P.C.B.
Refer to Fig. 1. SMPS P.C.B.
Refer to Fig. 1. SMPS P.C.B.
Refer to Schematic Diagram of
SMPS Circuit (Item 17.5) for
terminal pin count on primary and
secondary terminals
SMPS Circuit (Item 17.5) for
terminal pin count on primary and
secondary terminals
SMPS Circuit (Item 17.5)
2) Refer to Schematic Diagram of
1) Refer to Fig. 2. Main P.C.B.
Main Circuit (Item 17.3)
2) Refer to Schematic diagram of
1 Regulator IC IC2900
39
10.1.1.
SMPS P.C.B.
Fig. 1. SMPS P.C.B.
AC Inlet Jack : P5701
Fuse : F1
Regulator IC :
IC2900
IC2900
Thermal Diode :
D5706
D5706
Photocoupler :
PC701
PC701
H2016
Connector : H2016
Transformer : T5701
40
10.1.2.
Main P.C.B.
Fig. 2. Main P.C.B.
Transistor:Q100
D114
Chip Jumper:K102
Chip Jumper:K105
Chip Jumper:K304
(Side B of Main P.C.B.)
(Side A of Main P.C.B.)
Connector:CN100
Transistor:Q107
Connector:CN203
DC/DC CONVERTER
IC: IC106
IC: IC106
Inductors : L125
IC107
Click on the first or last page to see other SA-XH70GW / SA-XH70EE / SC-XH70EE service manuals if exist.