DOWNLOAD Panasonic SA-PT860E / SA-PT860EB / SA-PT860EG Service Manual ↓ Size: 8.83 MB | Pages: 127 in PDF or view online for FREE

Model
SA-PT860E SA-PT860EB SA-PT860EG
Pages
127
Size
8.83 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / DVD HOME THEATER SOUND SYSTEM
File
sa-pt860e-sa-pt860eb-sa-pt860eg.pdf
Date

Panasonic SA-PT860E / SA-PT860EB / SA-PT860EG Service Manual ▷ View online

8.3. Wireless Service Mode Summary Table
The service modes can be activated by pressing various button combination on the player and remote control unit.
Below is the summary of major checking:
Player buttons
Remote control unit buttons
Application
Note
FAST FORWARD
3
ID setting
(Refer to the section
“8.4.1. Service Mode
Table 1” for more
information).
STOP
(only in AUX)
4
RF channel 1 display
(Refer to the section
“8.4.2. Service Mode
Table 2” for more
information).
5
RF channel 2 display
6
RF channel 3 display
7
Auto RF channel display
Note: Main room refers to the location of the main unit.
33
SA-PT860E / SA-PT860EB / SA-PT860EG
8.4. Service Mode Table (Wireless - eg. SH-FX67)
By pressing various button combinations on the player and remote control unit, you can activate the various service modes for
checking.
8.4.1. Service Mode Table 1
FL Display
Key Operation
Front Key
Item
Description
Mode Name
ID Setting
Press the          on main 
unit or remote control.
Select in CD/DVD mode. 
Press and hold [FAST 
FORWARD] button on the 
main unit, and [3] button 
on the remote control unit.
Note :        will blink when a new transmitter 
card is inserted or when the Receiver 
module P.C.B.(Rx) has been changed.
  
   It will stopped when paining is completed.
To set the ID in the Tx & Rx. The 
system goes into "Pairing Mode".
[P] will be displayed for 60 seconds to 
indicate it is in "Pairing Mode".
During this condition, the "ID set" 
button on the receiver unit can be 
pressed to pair the Tx & Rx.
After 60 seconds, the FL display will
return to its previous display.
Note: Carry out pairing when Tx or Rx
has been changed. 
W1
W1
34
SA-PT860E / SA-PT860EB / SA-PT860EG
8.4.2. Service Mode Table 2
FL Display
Key Operation
Front Key
Item
Description
Mode Name
RF Channel
Selection
Display
RF Channel 1 Display*
FL Display sequence:
Display 1    2    3 
RF Channel 2 Display*
FL Display sequence:
Display 1    2    3 
Auto RF Channel Display*
FL Display sequence:
Display 1    2    3
*Note: 
*Note: This mode is for purpose of disabling/enabling the frequency of automatic allocation and be able to select a fixed
           RF channel (channels 1, 2 or 3).
After 2 seconds.
(Display 1)
(Display 2)
(Display 3)
After 2 seconds.
Main set is in AUX mode.
Main set is in AUX mode.
Main set is in AUX mode.
Main set is in AUX mode.
Press and hold [STOP] 
button on the main unit, 
and [4] button on the 
remote control unit.
Press and hold [STOP] 
button on the main unit, 
and [5] button on the 
remote control unit.
After 2 seconds.
Press and hold [STOP] 
button on the main unit, 
and [6] button on the 
remote control unit.
After 2 seconds.
Press and hold [STOP] 
button on the main unit, 
and [7] button on the 
remote control unit.
(Display 2)
(Display 1)
(Display 3)
(Display 2)
(Display 1)
(Display 3)
(Display 2)
(Display 1)
(Display 3)
RF Channel 3 Display*
FL Display sequence:
Display 1    2    3 
35
SA-PT860E / SA-PT860EB / SA-PT860EG
8.5. DVD Self Diagnostic Function-Error Code
8.5.1. Mechanism Error Code Table
Error 
Code
H01 Tray loading error
The tray opening and closing is abnormal. 
Press [     STOP] on main  
CLOSE and OPEN of the tray cannot be   
unit for next error.
carried out properly. Loading motor error,  
(OPEN time: OPEN
DV5 LSI IC (IC8001) error.
CLOSE         OPEN      
H01 at CLOSE: CLOSE     
OPEN         CLOSE H01)
H02 Spindle servo error
The spindle servo/motor is abnormal. The 
Press [     STOP] on main
FG pulse is abnormal. CLV servo error. 
unit for next error.
H03 Traverse servo error
The traverse is abnormal. (Traverse servo, 
Press [     STOP] on main
DV5 LSI IC (IC8001), TRV motor error.) 
unit for next error.
H04 Tracking servo error
Tracking coil NG (OPU unit abnormal),
Press [     STOP] on main
DV5 LSI IC (IC8001) error.
unit for next error.
H05 Seek time out error
It is not possible to access the disc. TOC
Press [     STOP] on main
cannot read. Abnormal disc etc. Pickup
unit for next error.
abnormal or disk is dirty. (TRV motor 
error, DV5 LSI IC (IC8001) error.) 
H07 Driver IC thermal shut
The spindle motor is abnormal. 
Press [     STOP] on main
down
(short between brushes)
unit for next error.
U11 Focus servo error
Focus coil, FE signal error. Disc may be 
Press [     STOP] on main
dirty.
unit for next error.
(Unfinalized DVD-R
is likely to become 
U11.)
Description of error
Automatic FL Display
Remarks
Diagnosis  Contents
36
SA-PT860E / SA-PT860EB / SA-PT860EG
Page of 127
Display

Click on the first or last page to see other SA-PT860E / SA-PT860EB / SA-PT860EG service manuals if exist.