8.4. Service Mode Table (Wireless-eg.SH-FX67)
By pressing various button combinations on the player and remote control unit, you can activate the various service modes for
checking.
checking.
8.4.1. Service Mode Table 1
FL Display
Key Operation
Front Key
Item
Description
Mode Name
ID Setting
Press the on main
unit or remote control.
unit or remote control.
Select in CD/DVD mode.
Press and hold [FAST
FORWARD] button on the
main unit, and [3] button
on the remote control unit.
FORWARD] button on the
main unit, and [3] button
on the remote control unit.
Note : will blink when a new transmitter
card is inserted or when the Receiver
module P.C.B.(Rx) has been changed.
It will stopped when paining is completed.
card is inserted or when the Receiver
module P.C.B.(Rx) has been changed.
It will stopped when paining is completed.
To set the ID in the Tx & Rx. The
system goes into "Pairing Mode".
[P] will be displayed for 60 seconds to
indicate it is in "Pairing Mode".
During this condition, the "ID set"
button on the receiver unit can be
pressed to pair the Tx & Rx.
After 60 seconds, the FL display will
return to its previous display.
system goes into "Pairing Mode".
[P] will be displayed for 60 seconds to
indicate it is in "Pairing Mode".
During this condition, the "ID set"
button on the receiver unit can be
pressed to pair the Tx & Rx.
After 60 seconds, the FL display will
return to its previous display.
Note: Carry out pairing when Tx or Rx
has been changed.
has been changed.
W1
W1
33
SA-PT560E / SA-PT560EB / SA-PT560EG
8.4.2. Service Mode Table 2
FL Display
Key Operation
Front Key
Item
Description
Mode Name
RF Channel
Selection
Display
Selection
Display
RF Channel 1 Display*
FL Display sequence:
Display 1 2 3
Display 1 2 3
RF Channel 2 Display*
FL Display sequence:
Display 1 2 3
Display 1 2 3
Auto RF Channel Display*
FL Display sequence:
Display 1 2 3
Display 1 2 3
*Note: This mode is for purpose of disabling/enabling the frequency of automatic
*Note: This mode is for purpose of disabling/enabling the frequency of automatic allocation and be able to select a fixed
allocation and be able to select a fixed
RF channel (channels 1, 2 or 3).
RF channel (channels 1, 2 or 3).
After 2 seconds.
(Display 1)
(Display 2)
(Display 3)
After 2 seconds.
Main set is in AUX mode.
Main set is in AUX mode.
Main set is in AUX mode.
Main set is in AUX mode.
Press and hold [STOP]
button on the main unit,
and [4] button on the
remote control unit.
button on the main unit,
and [4] button on the
remote control unit.
Press and hold [STOP]
button on the main unit,
and [5] button on the
remote control unit.
button on the main unit,
and [5] button on the
remote control unit.
After 2 seconds.
Press and hold [STOP]
button on the main unit,
and [6] button on the
remote control unit.
button on the main unit,
and [6] button on the
remote control unit.
After 2 seconds.
Press and hold [STOP]
button on the main unit,
and [7] button on the
remote control unit.
button on the main unit,
and [7] button on the
remote control unit.
(Display 2)
(Display 1)
(Display 3)
(Display 2)
(Display 1)
(Display 3)
(Display 2)
(Display 1)
(Display 3)
RF Channel 3 Display*
FL Display sequence:
Display 1 2 3
Display 1 2 3
34
SA-PT560E / SA-PT560EB / SA-PT560EG
8.5. DVD Self Diagnostic Function-Error Code
8.5.1. Mechanism Error Code Table
Error
Code
H01 Tray loading error
The tray opening and closing is abnormal.
Press [ STOP] on main
CLOSE and OPEN of the tray cannot be
unit for next error.
carried out properly. Loading motor error,
(OPEN time: OPEN
DV5 LSI IC (IC8001) error.
CLOSE OPEN
H01 at CLOSE: CLOSE
OPEN CLOSE H01)
H02 Spindle servo error
The spindle servo/motor is abnormal. The
Press [ STOP] on main
FG pulse is abnormal. CLV servo error.
unit for next error.
H03 Traverse servo error
The traverse is abnormal. (Traverse servo,
Press [ STOP] on main
DV5 LSI IC (IC8001), TRV motor error.)
unit for next error.
H04 Tracking servo error
Tracking coil NG (OPU unit abnormal),
Press [ STOP] on main
DV5 LSI IC (IC8001) error.
unit for next error.
H05 Seek time out error
It is not possible to access the disc. TOC
Press [ STOP] on main
cannot read. Abnormal disc etc. Pickup
unit for next error.
abnormal or disk is dirty. (TRV motor
error, DV5 LSI IC (IC8001) error.)
H07 Driver IC thermal shut
The spindle motor is abnormal.
Press [ STOP] on main
down
(short between brushes)
unit for next error.
U11 Focus servo error
Focus coil, FE signal error. Disc may be
Press [ STOP] on main
dirty.
unit for next error.
(Unfinalized DVD-R
is likely to become
U11.)
Description of error
Automatic FL Display
Remarks
Diagnosis Contents
35
SA-PT560E / SA-PT560EB / SA-PT560EG
8.5.2. DVD Module Error Code Table
Error
Code
U702 HDMI/DVI I2C
The communication error of I2C when
Press [ STOP] on main
communication error
connecting it with HDMI/DVI. For
unit for next error.
instance, when EDID information to which
information on the TV set side has been
described cannot be read, it is generated.
U703 HDMI/DVI attestation
When attestation (HDCP) with the TV
Press [ STOP] on main
error
side fails when connecting it with
unit for next error.
HDMI/DVI, it is generated.
U704 HDMI/DVI SRM
It is generated at the equipment to which
Press [ STOP] on main
Riborcerar
the TV set is Riborced when connecting it
unit for next error.
with HDMI/DVI.
U705 HDMI/DVI SRM disk
It is generated at the time of it is time
Press [ STOP] on main
falsification check
when illegal the SRM data of the
unit for next error.
error
reproducing disk (verify error), when
connecting it with HDMI/DVI.
F740 HDMI device key
I2C error when writing HDMI Key device
Press [ STOP] on main
into transmitter.
unit for next error.
F893 FLASH ROM IC data
Firmware error, DV5.0 LSI IC (IC8651)
Press [ STOP] on main
falsification error
error.
unit for next error.
F894 EEPROM IC
When failing in the access to EEPROM
Press [ STOP] on main
abnormality error
IC located in the DVD Module P.C.B.
unit for next error.
(IC8611).
F895 Language area
Firmware version agreement check for
Press [ STOP] on main
abnormal
factory preset setting failure prevention.
unit for next error.
F897 Initialization
Incomplete initialization after writing of
Press [ STOP] on main
error
new firmware (Factory preset setting
unit for next error.
failure prevention)
F899 The communication
Unsuitable combination of number of
Press [ STOP] on main
specification
system com and panel com used.
unit for next error.
disagreement
(Frimware)
between
micro-processor
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
36
SA-PT560E / SA-PT560EB / SA-PT560EG
Click on the first or last page to see other SA-PT560E / SA-PT560EB / SA-PT560EG service manuals if exist.