9.3. DVD Self Diagnostic Function - Error Code
9.3.1. Mechanism Error Code Table
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
H01
Tray loading error
The tray opening and
closing
is
abnormal.
CLOSE and OPEN of
the
tray
cannot
be
carried out properly.
Loading motor error, DV
5.0 LSI
IC (IC8001)
error.
Press [
] on main unit for
next error.
(OPEN time: OPEN
→ CLOSE →
OPEN
→ H01 at CLOSE: CLOSE →
OPEN
→ CLOSE → H01)
H02
Spindle servo error
The spindle servo/motor
is abnormal.
The
FG
pulse
is
abnormal.
CLV
servo
error.
Press [
] on main unit for
next error.
33
SA-NC6EB
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
H03
Traverse servo error The
traverse
is
abnormal.
(Traverse
servo, DV 5.0 LSI IC
(IC8001),
TRV
motor
error.)
Press [
] on main unit for
next error.
H04
Tracking servo error
Tracking coil NG (OPU
unit abnormal), DV 5.0
LSI IC (IC8001) error.)
Press [
] on main unit for
next error.
H05
Seek time out error
It is not possible to
access the disc.
TOC cannot read.
Abnormal disc etc.
Pickup abnormal or disc
is dirty.
(TRV motor error, DV
5.0 LSI
IC (IC8001)
error.)
Press [
] on main unit for
next error.
H07
Driver IC thermal
shut down
The spindle motor is
abnormal.
(short
between brushes)
Press [
] on main unit for
next error.
H15
Disc tray open
detection switch
failure
The disc tray cannot be
opened
&
it
closes
spontaneously.
Press [
] on main unit for
next error.
H16
Disc tray close
detection switch
failure
The disc tray cannot be
closed
&
it
opens
spontaneously.
Press [
] on main unit for
next error.
U11
Focus servo error
Focus coil, FE signal
error.
Press [
] on main unit for
next error.
(Unfinalized DVD-R is likely to become
U11.)
U15
Unfinalized DVD-R
F500
DSC error
DV 5.0 LSI IC (IC8001)
stops in the occurance of
servo
error
(startup,
focus error, etc)
Press [
] on main unit for
next error.
F506
Invalid media
Disc is flipped over, TOC
unreadable,
incompatible disc.
Press [
] on main unit for
next error.
F620
OPU unit abnormality
temperature
Laser protection at high
tempurature.
Press [
] on main unit for
next error.
F621
OPU unit circuitry
abnormal
Laser
protection
at
circuit failure.
Press [
] on main unit for
next error.
U701
HDMI/DVI HDCP
non-compliance
It is generated for the
connection
with
HDMI/DVI
when
the
equipment (TV set) does
not
correspond
to
HDCP.
(HDCP:
Copyright
protection
technology.
Encryption
method of digital image
signal.)
Press [
] on main unit for
next error.
U702
HDMI/DVI I2C
communication error
The
communication
error
of
I2C
when
connecting
it
with
HDMI/DVI. For instance,
when EDID information
to which information on
the TV set side has been
described
cannot
be
read, it is generated.
Press [
] on main unit for
next error.
34
SA-NC6EB
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
U703
HDMI/DVI attestation
error
When
attestation
(HDCP) with the TV side
fails when connecting it
with HDMI/DVI,
it is
generated.
Press [
] on main unit for
next error.
U704
HDMI/DVI SRM
Riborserar
It is generated at the
equipment to which the
TV set is Riborced when
connecting
it
with
HDMI/DVI.
Press [
] on main unit for
next error.
U705
HDMI/DVI SRM disc
falsification check
error
It is generated at the
time of it is time when
illegal the SRM data of
the
reproducing
disc
(verify
error).
When
connecting
it
with
HDMI/DVI.
Press [
] on main unit for
next error.
F893
FLASH ROM IC data
falsification error
Firmware error, DV 5.0
LSI IC (IC8651) error.
Press [
] on main unit for
next error.
F894
EEPROM IC
abnormality error
When
failing
in
the
access to EEPROM IC
located
in
the
DVD
(HDMI) Module P.C.B.
(IC8611)
Press [
] on main unit for
next error.
F895
Language area
abnormal
Firmware
version
agreement
check
for
factory
preset
setting
failure prevention.
Press [
] on main unit for
next error.
F896
No existence model
Firmware
version
agreement
check
for
factory
preset
setting
failure prevention.
Press [
] on main unit for
next error.
F897
Initialization error
Incomplete initialization
after
writing
of
new
firmware (Factory preset
setting
failure
prevention).
Press [
] on main unit for
next error.
F898
Disagreement of
hardware and
software
Unsuitable combination
of AV Decoder, SDRAM
&
FLASH
ROM
IC
(firmware).
Press [
] on main unit for
next error.
F899
The communication
specification
disagreement
between micro-
processor
Unsuitable combination
of number of system
com and panel com
used. (Firmware)
Press [
] on main unit for
next error.
9.3.2. Power Supply Error Code Table
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
F61
The abnormalities in
an output or power
supply circuit of
POWER AMP
In
normal
operation,
when DCDET2 goes to
“L” (not during power-off
condition), F61 appears
on
FL
display
and
PCONT goes to “L”. This
is due to speaker output
has DC voltage or fan is
not working.
Press [
] on main unit for
next error.
F76
Abnormality in the
output voltage of
stabilized power
supply
In
normal
operation
when
DCDET1
is
detected L (Low) for two
consecutive times, F76
is displayed on FL for 2
seconds and after that
PCONT will be turned to
L (Low). This is due to
any of the DC voltages
(+9V) +7V, -7V, +5V,
+5.3 etc) not available.
Press [
] on main unit for
next error.
35
SA-NC6EB
9.3.3. ECC Error Code Table
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
F600
Administrative
information cannot be
acquired by the
recovery error.
It become
impossible
NaviPack
etc.
were
done, and not to be able
to
acquire
necessary
information
in
the
navigation’s
changing
due to wound etc. of
DISC, and to have done
the
reproduction
transition.
Press [
] on main unit for
next error.
F601
Irregular sector ID
wad demanded.
It tried to access the
position that did not exist
on
DISC
by
the
recording error etc. of
authoring.
Press [
] on main unit for
next error.
F603
KEYDET cannot be
acquired by the
recovery error.
The data for decoding
copyright
protection
(CSS)
cannot
be
acquired due to wound
etc. of DISC, and it is not
possible to reproduce.
Press [
] on main unit for
next error.
Note:
An error code will be cancelled if a power supply is turned OFF.
*1: CPPM is the copy guard function beforehand written in the disc for protection of copyrights.
*2: CEC is the consumer electronic control used for high-level user control HDMI-connected devices.
*3: HDCP is the specification developed to control digital audio & video contents transmission for DVI or HDMI connections.
9.3.4. USB Error Code Table
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
F650
USB device: Devices
other than mass
storage
Devices other than the
mass storage class are
connected.
Press [
] on main unit for
next error.
(The generation D110, it mounts.)
F651
USB device: Non-Full
Speed Device
The
device
that
the
transfer rate did not
correspond
to
Full
Speed was connected.
Press [
] on main unit for
next error.
(The generation D110, it mounts.)
F652
USB device: Interface
NG
The
device
in
the
interface
(subclass)
outside correspondence
was
connected.
(Correspondence
interface
001b: Reduced Block
Commands (RBC)
010b: SFF-8020i. MMC-
2 (ATAPI)
110b: SCSI transparent
command set.
Press [
] on main unit for
next error.
(The generation D110, it mounts.)
F655
USB device:
Overcurrent detection
The
overcurrent
of
500mA or more was
detected in VDD USB,
and the USB device
driver
function
was
intercepted.
(To
intercept the current.)
Press [
] on main unit for
next error.
(The generation D110, it mounts.)
9.4. Doctor Mode
To enter into Doctor Mode, special remote control is needed.
36
SA-NC6EB
Page of 127
Display

Click on the first or last page to see other SA-NC6EB service manuals if exist.