DOWNLOAD Panasonic RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT Service Manual ↓ Size: 15.65 MB | Pages: 84 in PDF or view online for FREE

Model
RX-ES23GC RX-ES23GS RX-ES23GN RX-ES23GT
Pages
84
Size
15.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / PORTABLE STEREO CD SYSTEM
File
rx-es23gc-rx-es23gs-rx-es23gn-rx-es23gt.pdf
Date

Panasonic RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT Service Manual ▷ View online

3 Before Use
Be sure to disconnect the mains cord before adjusting the voltage selector. Use a minus (-) screwdriver to set the voltage selector
(on the rear panel) to the voltage setting for the area in which the unit will be used.
(If the power supply in your area is 117V or 120V, set to the “127V” position.)
Note that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries;
the correct voltage is already set.)
4 Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C301, C119, C219, C131, C231, C310, C307, C309 and C331 through
a 10
Ω, 1 W resistor to ground. DO NOT SHORT-CIRCUIT DIRECTLY (with a screw driver blade, for instance), as this may destroy
solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
(For GN) Current consumption at AC 230 - 240 V, 50 Hz in NO SIGNAL mode should be ~180 mA respectively.
(For GC/GS) Current consumption at AC 110 - 127 V / 220 - 240 V, 50/60 Hz in NO SIGNAL mode should be ~200 mA, 180mA
respectively.
(For GT) Current consumption at AC 110 V, 60 Hz in NO SIGNAL mode should be ~180 mA respectively.
5 Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
     ·    No sound is heard when the power is turned on.
     ·    Stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
 3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
6 Handling the Lead Solder
6.1. About lead free solder (PbF)
Distinction of PbF P.C.B. :
P.C.B.s (manufactured) using lead free solder will have a PbF stamp on the P.C.B.
Caution:
     ·    Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher.
Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F
(370 ± 10°C).
     ·    Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
     ·    When soldering or unsoldering, please completely remove all of the solder on the pins or solder area, and be sure to heat the
soldering points with the Pb free solder until it melts enough.
5
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
This unit utilizes a class 1 laser.
Invisible laser radiation is emitted from the optical pickup lens.
When the unit is turned on:
7 Precaution of Laser Diode
CAUTION:
 1. Do not look directly into the pick up lens.
 2. Do not use optical instruments to look at the pick up lens.
 3. Do not adjust the preset variable resistor on the pickup lens.
 4. Do not disassemble the optical pick up unit.
 5. If the optical pick up is replaced, use the manufacturer’s specified replacement pick up only.
 6. Use of control or adjustments or performance of procedures other than those specified herein may result in hazardous radiation
exposure.
CAUTION!
THIS PRODUCT UTILIZES A LASER.
USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT
IN HAZARDOUS RADIATION EXPOSURE.
6
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
The laser diode in the traverse deck (optical pickup) may break
down due to potential difference caused by static electricity of
clothes or human body.
So, be careful of electrostatic breakdown during repair of the
traverse deck (optical pickup).
l Handling of CD traverse deck (optical pickup)
 1. Do not subject the traverse deck (optical pickup) to
static electricity as it is extremely sensitive to electrical
shock.
 2. The short land between the No.4 (LD) and No.5 (GND)
pins on the flexible board (FFC) is shorted with a solder
build-up to prevent damage to the laser diode.
 3. Take care not to apply excessive stress to the flexible
board (FFC board) (Fig 6.1).
 4. Do not turn the variable
resistor
(laser
power
adjustment). It has already been adjusted.
Fig 6.1
l Grounding for electrostatic breakdown prevention
 1. Human body grounding (Fig 6.2)
Use the anti-static wrist strap to discharge the static
electricity from your body.
 2. Work table grounding (Fig 6.2)
Put a conductive material (sheet) or steel sheet on the
area where the traverse deck (optical pickup) is placed,
and ground the sheet.
Caution :
The static electricity of your clothes will not be grounded
through the wrist strap. So, take care not to let your
clothes touch the traverse deck (optical pickup).
Fig 6.2
Caution when Replacing the Optical Pickup :
The traverse has a short point shorted with solder to protect
the laser diode against electrostatics breakdown. Be sure to
remove the solder from the short point before making
connections.
8 Handling Precautions For Traverse Deck
7
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
9 Accessories
Note : Refer to Packing Materials & Accessories Parts List (Section 25.5) for the part number.
Remote Control.....1pc
AC cord.....1 pc (For
GN)
AC cord.....1 pc (For
GC)
AC cord.....1 pc (For
GS)
AC cord.....1 pc (For
GT)
AC cord
adaptor.....1
pc (For GC)
8
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
Page of 84
Display

Click on the first or last page to see other RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT service manuals if exist.