13 Procedure for checking of the major P.C.B.
13.1. Checking the Main P.C.B., Panel P.C.B., Deck Mechanism P.C.B., CD
Servo P.C.B., Battery P.C.B., Sensor P.C.B., Power and Standby LED
P.C.B.
Preparation
Follow items 12.2.1. to 12.2.7. of Disassembly Procedure.
29
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
14 Self Diagnostic Function
14.1. Self-Diagnosis Function
14.1.1. Entering into self-diagnosis mode
 1. Ensure there is no cassette tape in the deck unit.
 2. Switch to CD mode.
 3. Press and hold the [CD/TAPE STOPn] key of the main set for more than 2 seconds. While pressing this key, press the FF key
on the main set for another 2 seconds to enter into the self-diagnosi s mode.
Note:
Even if [CD/TAPE STOPn] key of the main set is pressed while the self diagnosis mode is on, function will not be switched.
Instead, confirmation of error numbers will begin.
14.1.2. Display Location
Figure 14-1
14.1.3. Error Code Display
     ·    At the self-diagnosi s mode, error codes will be displayed when [TAPE/CD STOPn] key at the main unit is pressed.
Note:
Error numbers display is due to error symptom encountered during normal operation of unit. These error codes will be
“remembered ” and stored.
     ·    Example: [T......H01] (the display shall be retained)
     ·    To exit from the self-diagnosi s mode, execute power OFF operation.
     ·    Even at power OFF operation, this error numbers shall not be cleared (the number can be cleared only at the start up of micro-
p after reset).
     ·    If repeating self-diagnosi s, add the newly detected errors only without deleting errors which have been detected before.
14.1.4. Error Code Table
Error code
Possible symptom
Description of problem
U01
Batteryflat
     ·    During operation, when PDET switches to OFF (PDET < 1.534V) due to fall of power supply voltage
fall, the power supply will be automatically switched OFF.
     ·    If REM_STBY = L, VCCDET = L the system shall be judged to have low battery and [......UO1] shall
be displayed for 10 seconds.
     ·    To check REM_STBY and VCCDET, chattering check will be read-in twice 1 sec after PCONT is set
to L.
     ·    In case of power ON operation, after PCONT is set to ‘H’, power supply shall be checked using
PDET input. If the battery is flat (PDET < 1.534V), power supply OFF process will be executed and
error number [......UO1] will be displayed for 5 seconds. This error number will not be memorized.
30
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
Error code
Possible symptom
Description of problem
U02
Power supply cut
     ·    During operation, when PDET switches to OFF (PDET < 1.534V) due to fall of power supply voltage
fall, the power supply will be automatically switched OFF.
     ·    If REM_STBY = L, VCCDET = H the system shall be judged to have low battery and [......UO2] shall
be displayed for 10 seconds.
     ·    To check REM_STBY and VCCDET, chattering check will be read-in twice 1 sec after PCONT is set
to L.
     ·    Power supply state shall be checked using REM_STBY and VCCDET inputs. If power ON is
executed from power OFF (REM_STBY = L and VCCDET = H), error number [......UO2] will be
displayed for 5 seconds. This error number will not be memorized.
F15
CD REST_SW
abnormal
     ·    At initial setting of CD traverse position, if REST_SW ON is not detected even though the fail safe
timer time is over (10 sec), this is memorized as an error and the error number can be cleared only
at the start up of micro-p after reset.
H15
CD OPEN_SW
abnormal
     ·    During normal operation, if CD OPEN_SW ON is not detected within 4 sec, then H15 will be
memorized in memory. The error code can be cleared only at the start up of micro-p after reset.
H01
DECK operation
abnormal (reel motor,
solenoid, and
MODE_SW)
(provisional)
     ·    During normal operation, if mechanism error process is executed once by mode switch against the
same deck operation, it is judged as mechanism abnormality and this is memorized as an error.
     ·    Conditions for judging mechanism error:
     − 
− 
− 
− Mode switch ON is not detected 800 ms after plunger activation for PLAY / REC process.
     − 
− 
− 
− Mode switch ON is not detected 800 ms after plunger activation for FF / REW process / Mode
switch OFF is not detected 800 ms after plunger activation after detecting Mode SW ON / Mode
Switch ON is not detected 800 ms after detecting Mode switch OFF.
     − 
− 
− 
− If Mode switch comes ON at STOP / PAUSE state (normal condition), this is judged as an Error:
 1. 
Main purpose for this self diagnosis is to diagnose a partial short of the deck.
 2. 
Mechanical error process caused by EJECT operation will not be counted.
 3. 
This error number can be cleared only at the start up of micro-p after reset.
F26
Communication
between CD servo LSI
and microp abnormal
     ·    At the time of switching to CD function, SENSE = H will be detected using DTMS system setting
command. If the error is memorized when SENSE = L is not detected within fail safe timer time (20
sec), [F26] will be displayed simultaneously. This display will be retained if the power is ON and at
CD function. If this error occurs, CD operation afterward cannot be executed as in the case of
[NO.DISC.]. This error number can be cleared only at the start up of micro-p after reset.
14.1.5. Self-Diagnosis mode Deck Mechanism
     ·    Activate the self diagnosis mode for the Deck and the following self diagnosis will be conducted.
Error Code
Description
H01:
If MODE_SW abnormal is detected during normal operation, it will be memorized. The detection and memory
shall be done for Deck.
H02:
RECINH_SW abnormal.
H03:
HALF_SW abnormal.
F01:
Reel pulse abnormal.
     ·    Operating Procedures
 1. Activate the self diagnosis mode with the Deck unloaded.
 2. The test mode will be displayed ([T] at the 1st digit shows TEST) and detection shall be executed to check RECINH_SW,
HALF_SW are in the OFF state (the tape counter display is retained).
 3. Load a cassette tape (with recording preventive tab present) into the deck and close the cassette holder.
 4. At this instant with the cassette loaded in, RECINH_SW, HALF_SW will be checked and confirmed at this stage by the software.
Press FF key to proceed the self-diagnosi s. The FF operation will stop automatically after 3 sec. If abnormal operation is
detected, the tape will stop automatically after 1 sec. During the FF operation, the Reel Pulse will be checked by the software.
 5. After the tape stops, the Error codes will be displayed by toggling the STOPn key. (For a more detailed explanation, refer to
Figure 14-2).
31
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
Figure 14-2
14.2. Setting of doctor mode
 1. Switch to CD mode. (Ensure no disc is inserted)
 2. To enter Doctor mode, press and hold [TAPE/CD STOPn] key at the main unit, followed by [4] & [7] on remote control.
 3. When the Doctor Mode is activated the LCD display will show the
symbol at the 5
th
digit. At the same time, the micro-p
version number (base 10) and EEPROM’s checksum (base 16) will be displayed for 1 sec. After displaying the EEPROM
information for 1 sec, the display will return to the normal Doctor mode display
32
RX-ES23GC / RX-ES23GS / RX-ES23GN / RX-ES23GT
Page of 84