Installer setup Operation setup
2
Heat
To set various water & ambient
temperatures for heating.
Water temp. for heating ON /
Outdoor temp. for heating OFF /
T for heating ON /
Outdoor temp. for heater ON
Water temp. for heating ON
Compensation
curve
Heating ON
temperatures in
compensation curve or
direct input.
Water temp. for heating ON Compensation curve
X axis: -5 °C, 15 °C
Y axis: 55 °C, 35 °C
Input the 4 temperature
points
(2 on horizontal X axis,
2 on vertical Y axis).
• Temperature range: X axis: -15 °C ~ 15 °C, Y axis: See below
• Temperature range for the Y axis input:
• Temperature range for the Y axis input:
1. If High water temperature is NO: 20 °C ~ 55 °C
2. If High water temperature is YES & Back up heater is enabled: 25 °C ~ 65 °C
3. If High water temperature is YES & Back up heater is disabled: 35 °C ~ 65 °C
• If 2 zone system is selected, the 4 temperature points must also be input for Zone 2
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for heating ON Direct
35 °C
Temperature for heating
ON
• Min. ~ Max. range is conditional as follows:
1. If High water temperature is NO: 20 °C ~ 55 °C
2. If High water temperature is YES & Back up heater is enabled: 25 °C ~ 65 °C
3. If High water temperature is YES & Back up heater is disabled: 35 °C ~ 65 °C
Outdoor temp. for heating OFF
24 °C
Temperature for heating
OFF
38
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
T for heating ON
5 °C
Set
Set
T for heating
ON.
Outdoor temp. for heater ON
0 °C
Temperature for
heater ON
3
*
1,
*
2
Cool
To set various water & ambient
temperatures for cooling.
Water temperatures for cooling ON
and T for cooling ON.
Water temp. for cooling ON
Compensation curve
Cooling ON
temperatures in
compensation curve or
direct input.
Water temp. for cooling ON Compensation curve
X axis: 20 °C, 30 °C
Y axis: 15 °C, 10 °C
Input the 4 temperature
points
(2 on horizontal X axis,
2 on vertical Y axis)
• If 2 zone system is selected, the 4 temperature points must also be input for Zone 2.
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for cooling ON Direct
10 °C
Set temperature for
Cooling ON
T for cooling ON
5 °C
T for cooling ON
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
39
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
4
Auto
Automatic switch from Heat to
Cool or Cool to Heat.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
Outdoor temp. for (Heat to Cool)
15 °C
Set outdoor temperature
for switching
from Heat to Cool.
Outdoor temp. for (Cool to Heat)
10 °C
Set outdoor temperature
for switching
from Cool to Heat.
5
Tank
Setting functions for the tank.
• Available only if connected to
the tank.
Floor operation time (max) /
Tank heat up time (max) /
Tank re-heat temp. /
Sterilization
• The display will show 3 functions at a time.
Floor operation time (max)
8:00
Maximum time for floor
operation
(in hours and minutes)
Tank heat up time (max)
1:00
Maximum time for
heating the tank
(in hours and minutes)
Tank re-heat temp.
-8 °C
Set temperature to
perform reboil of tank
water.
40
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
Sterilization
Sterilization may be set for 1 or
more days of the week.
Sun / Mon / Tue / Wed / Thu / Fri / Sat
Sterilization: Time
Time of the selected day(s) of the week to
sterilize the tank
0:00 ~ 23:59
Sterilization: Boiling temp.
65 °C
Set boiling temperatures
for sterilize the tank.
Sterilization: Ope. time (max)
0:10
Set sterilizing time
(in hours and minutes)
Installer setup Service setup
1
Pump maximum speed
To set the maximum speed of
the pump.
Setting the flow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
2
Pump down
To set the pump down operation. Pump down operation
ON
Click on the first or last page to see other WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 service manuals if exist.