DOWNLOAD Panasonic WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 Service Manual ↓ Size: 17.29 MB | Pages: 127 in PDF or view online for FREE

Model
WH-SDC03H3E5-1 WH-SDC05H3E5-1 WH-SDC07H3E5-1 WH-SDC09H3E5-1 WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1
Pages
127
Size
17.29 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Air Conditioner / AIR-TO-WATER HEATPUMP
File
wh-sdc03h3e5-1-wh-sdc05h3e5-1-wh-sdc07h3e5-1-wh-sd.pdf
Date

Panasonic WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 Simplified Service Manual ▷ View online

37 
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
Installer setup  Operation setup
2
 Heat
To set various water & ambient
temperatures for heating.
Water temp. for heating ON /
Outdoor temp. for heating OFF /
T for heating ON /
Outdoor temp. for heater ON
 Water temp. for heating ON
Compensation
curve
Heating ON
temperatures in
compensation curve or
direct input.
 Water temp. for heating ON  Compensation curve
X axis: -5 °C, 15 °C
Y axis: 55 °C, 35 °C
Input the 4 temperature
points
(2 on horizontal X axis,
2 on vertical Y axis).
• Temperature range: X axis: -15 °C ~ 15 °C, Y axis: See below
• Temperature range for the Y axis input:
1. If High water temperature is NO: 20 °C ~ 55 °C
2. If High water temperature is YES & Back up heater is enabled: 25 °C ~ 65 °C
3. If High water temperature is YES & Back up heater is disabled: 35 °C ~ 65 °C
• If 2 zone system is selected, the 4 temperature points must also be input for Zone 2
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
 Water temp. for heating ON  Direct
35 °C
Temperature for heating
ON
• Min. ~ Max. range is conditional as follows:
1. If High water temperature is NO: 20 °C ~ 55 °C
2. If High water temperature is YES & Back up heater is enabled: 25 °C ~ 65 °C
3. If High water temperature is YES & Back up heater is disabled: 35 °C ~ 65 °C
 Outdoor temp. for heating OFF
24 °C
Temperature for heating
OFF
 
 
38 
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
T for heating ON
5 °C
Set
Set
T for heating
ON.
 Outdoor temp. for heater ON
0 °C
Temperature for
heater ON
3
 *
1,
 *
2
 Cool
To set various water & ambient
temperatures for cooling.
Water temperatures for cooling ON
and T for cooling ON.
 Water temp. for cooling ON
Compensation curve
Cooling ON
temperatures in
compensation curve or
direct input.
 Water temp. for cooling ON  Compensation curve
X axis: 20 °C, 30 °C
Y axis: 15 °C, 10 °C
Input the 4 temperature
points
(2 on horizontal X axis,
2 on vertical Y axis)
• If 2 zone system is selected, the 4 temperature points must also be input for Zone 2.
• “Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
 Water temp. for cooling ON  Direct
10 °C
Set temperature for
Cooling ON
T for cooling ON
5 °C
T for cooling ON
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service  partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available).
 
 
39 
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
4
 Auto
Automatic switch from Heat to
Cool or Cool to Heat.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
 Outdoor temp. for (Heat to Cool)
15 °C
Set outdoor temperature
for switching
from Heat to Cool.
 Outdoor temp. for (Cool to Heat)
10 °C
Set outdoor temperature
for switching
from Cool to Heat.
5
 Tank
Setting functions for the tank.
• Available only if connected to
the tank.
Floor operation time (max) /
Tank heat up time (max) /
Tank re-heat temp. /
Sterilization
• The display will show 3 functions at a time.
 Floor operation time (max)
8:00
Maximum time for floor
operation
(in hours and minutes)
 Tank heat up time (max)
1:00
Maximum time for
heating the tank
(in hours and minutes)
 Tank re-heat temp.
-8 °C
Set temperature to
perform reboil of tank
water.
 
 
40 
y
a
l
p
s
i
D
/
s
n
o
it
p
O
g
n
it
t
e
S
g
n
it
t
e
S
tl
u
a
f
e
D
u
n
e
M
 Sterilization
Sterilization may be set for 1 or
more days of the week.
Sun / Mon / Tue / Wed / Thu / Fri / Sat
 Sterilization: Time
Time of the selected day(s) of the week to
sterilize the tank
0:00 ~ 23:59
 Sterilization: Boiling temp.
65 °C
Set boiling temperatures
for sterilize the tank.
 Sterilization: Ope. time (max)
0:10
Set sterilizing time
(in hours and minutes)
Installer setup  Service setup
1
 Pump maximum speed
To set the maximum speed of
the pump.
Setting the flow rate, max. duty and operation