13
Item
Unit
Outdoor Unit
Refrigeration Charge Less
m (ft)
10 (32.8)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
kW
1.70
Fan
Type
Propeller Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
-
Output Power
W
60
Fan Speed
rpm
Cooling: 670
Heating: 570
Heating: 570
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated
Fin
Row × Stage × FPI
2 × 30 × 17
Size (W × H × L)
mm
38.1 × 762.0 × 873.8 : 903.8
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
kW
Cooling: 2.28
Heating: 1.57
Heating: 1.96
Maximum Input Power For Heatpump System
kW
4.59
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 21.0 / 4.59k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 13.0 / 3.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
- / - / -
Starting Current
A
7.2
Running Current
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
A
Cooling: 10.3
Heating: 7.2
Heating: 9.0
Maximum Current For Heatpump System
A
21.0
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Power factor means total figure of compressor and
outdoor fan motor.
%
Cooling: 96
Heating: 95
Heating: 95
Power Cord
Number of core
-
Length m
(ft)
-
Thermostat
Electronic
Control
Protection Device
Electronic Control
14
Item
Unit
Indoor Unit
Performance Test Condition
EN 14511
Operation Range
Outdoor Ambient
°C
Cooling: 16 ~ 43
Heating: -20 ~ 35
Water Outlet
°C
Cooling: 5 ~ 20
Heating: 20 ~ 55
Internal Pressure Differential
kPa
Cooling: 18.0
Heating: 24.0
Heating: 24.0
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A)
Cooling: 30
Heating: 30
-
Power Level dB
Cooling: 43
Heating: 43
-
Dimension
Height
mm (inch)
892 (35-1/8)
Width
mm (inch)
500 (19-11/16)
Depth
mm (inch)
340 (13-13/32)
Net Weight
kg (lbs)
44 (97)
Refrigerant Pipe Diameter
Liquid
mm (inch)
6.35 (1/4)
Gas
mm (inch)
15.88 (5/8)
Water Pipe Diameter
Inlet
mm (inch)
31.75 (1-1/4)
Outlet
mm (inch)
31.75 (1-1/4)
Water Drain Hose Inner Diameter
mm (inch)
12 (15/32)
Pump
Motor Type
DC Motor
No. of Speed
7 (Software Selection)
Input Power
W
48
Hot Water Coil
Type
Brazed
Plate
No. of Plates
48
Size (W × H × L)
mm
82 × 93 × 325
Water Flow Rate
l/min (m
3
/h)
Cooling: 17.6 (1.1)
Heating: 20.1 (1.2)
Heating: 20.1 (1.2)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 266 and below
Flow Switch
Electronic Sensor
Protection Device
A
Residual Current Circuit Breaker (30 ~ 40)
Expansion Vessel
Volume I
10
MWP bar
3
Capacity of Integrated Electric Heater
kW
3.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Flow rate indicated are based on nominal capacity adjustment of leaving water temperature (LWT) 35°C and
=5°C
15
2.4 WH-SDC09H3E5-1
WH-UD09HE5-1
Item
Unit
Outdoor Unit
Performance Test Condition
EN 14511
Cooling Capacity
Condition
(Ambient/Water)
A35W7
kW 7.00
BTU/h 23900
kcal/h 6020
Cooling EER
W/W 2.43
kcal/hW 2.09
Heating Capacity
Condition
(Ambient/Water)
A7W35 A2W35
kW 9.00
6.70
BTU/h 30700
22800
kcal/h 7740
5760
Heating COP
W/W 4.13
3.13
kcal/hW 3.55
2.69
Heating ErP
Low Temperature Application (W35)
Warmer Average Colder
Application Climate
Pdesign kW
7.0
6.0
7.0
Tbivalent / TOL
°C
2 / 2
-10 / -10
-15 / -22
SCOP / ns
(W/W) / %
5.69 / 225
4.83 / 190
4.08 / 160
Annual Consumption
kWh
1643
2566
4233
Class
A++
A++
A++
Medium Temperature Application (W55)
Warmer Average Colder
Application Climate
Pdesign kW
6.0
7.0
6.0
Tbivalent / TOL
°C
2 / 2
-6 / -10
-15 / -22
SCOP / ns
(W/W) / %
4.07 / 160
3.32 / 130
2.95 / 115
Annual Consumption
kWh
1971
4354
5022
Class
A++
A++
A+
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A)
Cooling: 50
Heating: 51
-
Power Level dB
Cooling: 68
Heating: 69
-
Air Flow
m
3
/min (ft
3
/min)
Cooling: 56.3 (1987)
Heating:51.0 (1800)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S
(900)
Refrigerant (R410A)
kg (oz)
1.45 (51.2)
F-GAS
GWP 2088
CO2eq (ton) (Precharged / Maximum)
3.028 / 4.280
Dimension
Height
mm (inch)
795 (31-5/16)
Width
mm (inch)
900 (35-7/16)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
66 (146)
Pipe Diameter
Liquid
mm (inch)
6.35 (1/4)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 40 (131)
I/D & O/D Height Difference
m (ft)
30 (98.4)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
16
Item
Unit
Outdoor Unit
Refrigeration Charge Less
m (ft)
10 (32.8)
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Rated Output
kW
1.70
Fan
Type
Propeller Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
-
Output Power
W
60
Fan Speed
rpm
Cooling: 700
Heating: 640
Heating: 640
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated
Fin
Row × Stage × FPI
2 × 30 × 17
Size (W × H × L)
mm
38.1 × 762.0 × 873.8 : 903.8
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
kW
Cooling: 2.88
Heating: 2.18
Heating: 2.14
Maximum Input Power For Heatpump System
kW
5.01
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 22.9 / 5.01k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
1Ø / 13.0 / 3.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
- / - / -
Starting Current
A
10.0
Running Current
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
A
Cooling: 13.0
Heating: 10.0
Heating: 9.8
Maximum Current For Heatpump System
A
22.9
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Power factor means total figure of compressor and
outdoor fan motor.
%
Cooling: 96
Heating: 95
Heating: 95
Power Cord
Number of core
-
Length m
(ft)
-
Thermostat
Electronic
Control
Protection Device
Electronic Control
Click on the first or last page to see other WH-SDC03H3E5-1 / WH-SDC05H3E5-1 / WH-SDC07H3E5-1 / WH-SDC09H3E5-1 / WH-UD03HE5-1 / WH-UD05HE5-1 / WH-UD07HE5-1 / WH-UD09HE5-1 service manuals if exist.