10.2.2  Noise Filter Printed Circuit Board 
 
FG202
FG203
N-IN
L3-IN
FG201
L1-IN
L2-IN
L2-OUT
L1-OUT
L3-OUT
N-OUT
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
30 
11.  Installation Instruction 
Mono Bloc Unit 
 
Dimension Diagram 
 
Front view
Bottom view
Rear view
50
83
.
5
45
45
45
24.
5
27
3
40
0
980
150
28
41
3
27
5
175
320
1283
39
141
0
13
40
20
Water Outlet Pipe
Water Inlet Pipe
30
0m
m
or
 mo
re
300mm
or more
10
00
mm
or
 m
or
e
100mm o
r
more
Drain hose connector
 
 
 
 
 
 
31 
Main Components 
 
Component name
PCB
Pressure relief valve
Flow switch
Pressure gauge
Water pump
RCCB
Bushing
Cabinet front plate
Connector name
Water inlet
Water outlet
Cabinet top plate
Overload protector
Heater assembly
Expansion vessel
Cover
Air purge valve
1
2
a
b
3
4
5
6
7
8
9
10
11
12
13
14
2
7
8
1
13
10
6
3
4
11
12
5
A
14
9
a
b
(VIEW
WITHOUT
COVER)
DETAIL A
(WITHOUT OLP
COVER)
View without cabinet top plate
Optional cord / cable :-
2-way valve cable (3 × min 0.5mm²)
3-way Valve cable (3 × min 0.5mm²)
Booster Heater cord (3 × min 1.5mm²)
Room Themostat cable (4 or 3 × min 0.5mm²)
Tank OLP cable (2 × min 0.5mm²)
Tank Sensor cable (2 × min 0.3mm²)
External Controller cable (2 × min 0.5mm²)
Solar Three-way Valve cable (3 × min 0.5mm²)
Solar Pump Station cable (2 × min 0.5mm²)
Type
designation
60245 IEC
57 or heavier
cord / cable
Remote Control
Power Supply 1
Power Supply 2
7
 
 
It is advisable to avoid more than 2 blockage directions. 
For better ventilation & multiple-outdoor installation,  
please consult authorized dealer/specialist. 
32 
11.1  Select The Best Location 
  Install the Mono bloc unit in outdoor locations only. 
  Avoid installations in areas where the ambient 
temperature may drop below -20°C. 
  The Mono bloc unit must be installed on a flat, 
solid surface. 
  A place removed from any heat source or steam 
which may affect the operation of the Mono bloc 
unit. 
  A place where air circulation is good. 
  A place where drainage can be easily done. 
  A place where Mono bloc unit’s operation noise 
will not cause discomfort to the user. 
  A place which is accessible for maintenance. 
  Ensure to keep minimum distance of spaces as 
illustrated below from wall, ceiling, or other 
obstacles. 
  A place where flammable gas leaking might not 
occur. 
  A place where the Mono bloc unit’s piping and 
wiring lengths come within reasonable ranges. 
  If an awning is built over the unit to prevent direct 
sunlight or rain, be careful that heat radiation from 
the condenser is not obstructed. 
  Do not place any obstacles which may cause a 
short circuit of the discharged air. 
  Avoid installing the Mono bloc unit at a location 
where suction side may be exposed directly to 
wind. 
  If Mono bloc unit installed near sea, region with 
high content of sulphur or oily location (e.g. 
machinery oil, etc.), it lifespan maybe shorten. 
  When installing the product in a place where it will 
be affected by typhoon or strong wind such as 
wind blowing between buildings, including the 
rooftop of a building and a place where there is no 
building in surroundings, fix the product with an 
overturn prevention wire, etc. (Overturn prevention 
fitting model number: K-KYZP15C) 
 
 
 
  When connecting solar pump station cable 
between Mono bloc unit and solar pump station, 
the distance between both apparatuses shall be 
2 ~ 8 meters and the maximum length of 10 meter 
only. 
Failure to do so may lead to abnormal operation to 
the system. 
 
 
 
11.2  Mono Bloc Unit Installation 
Mono bloc unit will become heavy when filled with 
water. Please install the unit on a strong concrete floor 
and consider the weight of the unit and water. 
  Fix Mono bloc unit on the concrete floor with M12 
anchor bolt at 4 locations. 
  Pull-out strength of these anchor bolts must be 
above 15000N. 
 
Grip anchor bolt
Broken stone
Anchor bolt
60mm or more
300mm or
more
Floor
Concrete
Embedded anchor bolt
Anchor bolt
Floor slab (concrete)
Above
20mm
80mm
Compress strength of concrete is above 18MPa {180kgf/cm
2
}
 
 
Illustration of grip type and embedded type anchor bolt 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127