Panasonic CU-4E27PBD / CU-5E34PBD Service Manual ▷ View online
49
Cooling
Characteristic
[Condition] Room
temperature: 27°C (DBT), 19°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
230V 50Hz
D) Indoor unit capacity: Cooling (4.0: CS-E15PKDW)
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
13.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
O
u
tdoor
T
e
mper
at
ure
(
°C
)
Outdoor Air Temperature (°C)
230
2.600
2.800
3.000
3.200
3.400
3.600
3.800
4.000
4.200
4.400
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
Cooling
Ca
p
a
ci
ty
(
kW
)
Outdoor Air Temperature (°C)
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
0.680
0.700
0.720
0.740
0.760
0.780
0.800
0.820
0.840
0.860
0.880
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
G
a
s S
ide
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
50
Cooling
Characteristic
[Condition] Room
temperature: 27°C (DBT), 19°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
230V 50Hz
E) Indoor unit capacity: Cooling (5.0: CS-E18PKDW)
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
13.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
Ou
td
o
o
r
T
e
mper
at
ure
(
°C
)
Outdoor Air Temperature (°C)
230
2.500
3.000
3.500
4.000
4.500
5.000
5.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
Cooling
C
apacity
(kW
)
Outdoor Air Temperature (°C)
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
0.680
0.700
0.720
0.740
0.760
0.780
0.800
0.820
0.840
0.860
0.880
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
G
a
s S
ide
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
51
Cooling
Characteristic
[Condition] Room
temperature: 27°C (DBT), 19°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
230V 50Hz
F) Indoor unit capacity: Cooling (7.0: CS-E24PKDW)
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
13.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
Ou
td
o
o
r
T
e
mper
at
ure
(
°C
)
Outdoor Air Temperature (°C)
230
2.500
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
Cooling
C
apacity
(kW
)
Outdoor Air Temperature (°C)
3.000
4.000
5.000
6.000
7.000
8.000
9.000
10.000
11.000
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
0.680
0.700
0.720
0.740
0.760
0.780
0.800
0.820
0.840
0.860
0.880
-10
-6
-2
2
6
10
14
18
22
26
30
34
38
42
46
G
a
s S
ide
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
52
Heating
Characteristic
[Condition] Room
temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
230V 50Hz
A) Indoor unit capacity: Heating (2.2: CS-E7PKDW)
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
Ou
td
o
o
r
T
e
mper
at
ure
(
°C
)
Outdoor Air Temperature (°C)
230
1.000
1.500
2.000
2.500
3.000
3.500
4.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
H
eating
C
apacity
(kW
)
Outdoor Air Temperature (°C)
4.300
4.400
4.500
4.600
4.700
4.800
4.900
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
1.000
1.200
1.400
1.600
1.800
2.000
2.200
2.400
2.600
2.800
3.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
G
a
s S
ide
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
Click on the first or last page to see other CU-4E27PBD / CU-5E34PBD service manuals if exist.