DOWNLOAD Panasonic CS-W7CKP / CU-W7CKP5 / CS-W9CKP / CU-W9CKP5 / CS-W12CKP / CU-W12CKP5 Service Manual ↓ Size: 9.25 MB | Pages: 87 in PDF or view online for FREE

Model
CS-W7CKP CU-W7CKP5 CS-W9CKP CU-W9CKP5 CS-W12CKP CU-W12CKP5
Pages
87
Size
9.25 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-w7ckp-cu-w7ckp5-cs-w9ckp-cu-w9ckp5-cs-w12ckp-cu.pdf
Date

Panasonic CS-W7CKP / CU-W7CKP5 / CS-W9CKP / CU-W9CKP5 / CS-W12CKP / CU-W12CKP5 Service Manual ▷ View online

Note:
 1. 24 times checking: Actual Ion ON for 10s & OFF for 1s 30 min continuously for 24 times.
 2. 24 times count will be cleared when following conditions happen.
a) 24 times count over, b) Ionizer cancel if press Ion button or power reset, c) Ion f/b sgnl OK.
 3. Error protection will be cleared when following conditions happen.
a) Power reset, b) Remocon operation ON/OFF button press, c) Forcible operation press, d) Opt OFF due to Timer OFF
 4. Ion auto restart: Ion will auto restart if Actual Ion was ON with no error protection control before power shutdown. Otherwise
Ion will not auto restart.
 5. Ion LED blinking can ON/OFF during error protection by following conditions:
a) Press remocon ion button
b) Press emergency opt SW to OFF blinking.
37
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
38
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
9 Operating Instructions
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
● To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
● Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
!
 Warning
This sign warns of death or serious injury.
!
 Caution
This sign warns of damage to property.
● The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
These symbols (with a black background) denote
actions that are COMPULSORY.
OFF
■ Installation Precautions
!
 Warning
● This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
● Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
● Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
● Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
!
 Caution
■ Operation Precautions
!
 Warning
This sign warns of death or serious injury.
● Do not share outlet.
● Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
● Do not operate with wet hands.
● Do not damage or modify the power cord.
● Do not insert finger or other objects into the
indoor or outdoor units.
● Do not expose directly to cold air for a long
period.
● Plug in properly.
● Use specified power cord.
● If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
!
 Caution
This sign warns of injury.
● Do not pull the cord to disconnect the plug.
● Do not wash the unit with water.
● Do not use for other purposes such as
preservation.
● Do not use any combustible equipment at
airflow direction.
● Do not sit or place anything on the outdoor
unit.
● Switch off the power supply before cleaning.
● Ventilate the room regularly.
● Pay attention as to whether the installation
rack is damaged after long period of usage.
● Switch off the power supply if the unit is not
used for a long period.
OFF
OFF
NAME OF EACH PART
■ Indoor Unit
1 Front Panel
2 Air Intake Vent
3 Power Supply Cord
4 Air Outlet Vent
5 Vertical Airflow Direction Louver
6 Horizontal Airflow Direction Louver
(manually adjusted)
7 Indicator Panel
1 Auto Operation Button
(when the front panel is opened)
2 Powerful Mode Indicator – ORANGE
3 Ionizer Mode Indicator
GREEN
4 Power Indicator
GREEN
5 Quiet Mode Indicator
ORANGE
6 Timer Mode Indicator
ORANGE
● Indoor Unit
(when the front panel is opened)
1 Front Panel
2 Air Filters
3 Air Purifying Filter
■ Outdoor Unit
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Connecting Cable
5 Drain Hose
6 Air Outlet Vents
■ Accessories
 Remote Control
 Remote Control Indication Sticker
 Remote Control Holder
 Two RO3 (AAA) dry-cell batteries or equivalent
 Air Purifying Filter
CH
EC
K
TE
M
P
AU
T
AUT
O
ON
OFF
AU
T
AUT
O
DR
DR
Y F
AN
AN
COO
L
COOL
FA
N
AN
AU
T
AUT
O
RE
SE
T
BAT
TE
RY
CLO
CK
MO
DE
SLE
EP
ECO
NOM
Y
FAN
 SPE
ED
AIR
 SW
IN
G
OF
F
CAN
CEL
ON
SE
T
Ste
p
1
2
3
TIM
ER
+
HE
A
HEA
T
OF
F/O
N
1
2
3
4
5
7 6
2
1
3
1
6
2
3
4
5
1
2 3
6
5
4
(Catechin Air
Purifying Filter)
(Triple Deodorizing
Filter)
39
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
NAME OF EACH PART
■ Remote Control
● Remote Control Signal.
• Make sure it is not obstructed.
• Maximum distance : 10 m.
• Signal received sound.
One short beep or one long beep.
● Notes for Remote Control.
• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
CHECK
TEMP
AUTO
ON
OFF
AUT
AUTO
DR
DRY FAN
AN
COOL
COOL
FAN
AUTO
RESET CLOCK
MODE
POWERFUL
QUIET
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
AUTO
MANUAL
#
!
$
%
^
$
*
&
3
5
8
7
9
0
6
4
(
2
1
HEA
HEAT
● How  to Insert the Batteries
1
Slide down the remote control cover completely
2
Insert the batteries
– Be sure the direction is correct
– 12.00 at display - flashing
• Set the current time (CLOCK) immediately to
prevent battery exhaustion.
● About the batteries
• Can be used for approximately one year.
● Observe the following when replacing the
batteries
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
1 Signal Transmitter
2 Operation Display
3 Ionizer Mode Operation Button
4 Room Temperature Setting Button
(illuminating button)
5 Operation Mode Selection Button
6 Quiet Mode Operation Button
7 Auto Airflow Direction Button
8 ON-Timer Button
9 OFF-Timer Button
0 Reset Point
(Press with fine-tipped object to clear the memory)
! OFF/ON Button
(illuminating button)
@ Powerful Mode Operation Button
# Fan Speed Selection Button
$ Manual Airflow Direction Selection Button
% Timer Set Button
^ Timer Cancellation Button
& Time-Setting Button
* Clock Button
( Remote Control Cover
CHECK
AU
TO
OF
AU
TO
HEA
T
DR
Y FA
N
COOL
FA
N
AU
TO
AU
TO
RESET
CLOCK
AIR
 SW
IN
G
OF
F
CAN
CEL
1
2
3
TIM
ER
PO
WERFUL
AU
TO
MA
NU
AL
EC
ONO
MY
SLE
ON
SE
T
FAN SPEED
MO
DE
2
1
1.5V
1.5V
PREPARATION BEFORE OPERATION
■ Indoor Unit
1
Connect the power supply cord to an independent
power supply
2
Open the front panel
3
Remove the air filters
4
Fit the air purifying filters in place
5
Insert the air filters
6
Close the front panel
■ Remote Control
– To set the current time
1
Press 
1.
2
Then press 
2 to increase or decrease the time.
3
Press 
1 again.
Set time at display will light up.
CHECK
AUTO
AUTO HEAT
DRY FAN
COOL
FAN
AUTO
RESET CLOCK
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
AUTO
MANUAL
1
2
6
2
1
4
5
3
■ Setting Temperature
• Press 
3 to increase or decrease the temperature.
• The temperature can be set between 16°C ~ 30°C.
• Recommended temperature:
• During AUTO Operation, press 
3 to select:-
Operation with 2°C higher than the standard
temperature.
Operation with the standard temperature.
Operation with 2°C lower than the standard
temperature.
● Standard Temperature
Cooling Model
• Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
Heat Pump Model
• At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
• The operation mode changes every hour, when
necessary.
Operation
Cooling
Soft Dry
Standard
temperature
25°C
22°C
Indoor
temperature
23°C
HOW TO OPERATE
■ To start the operation
• Press 
1.
• POWER indicator (green) on the indoor unit will light
up.
• To stop, press once more.
■ Setting Mode
• Press 
2 to select:-
Cooling Model
AUTO
– Automatic Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
FAN
– Air Circulation Operation
Heat Pump Model
AUTO
– Automatic Operation
HEAT
– Heating Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
Operation
Cooling
Soft Dry
Heating
Standard
temperature
25°C
22°C
21°C
Indoor
temperature
23°C
20°C
Heat Pump Model
COOL –> 26°C ~ 28°C
DRY
–>   1°C ~   2°C
lower than the
room temperature
HEAT –> 20°C ~ 24°C
Cooling Model
COOL –>   26°C ~ 28°C
DRY
–>       1°C ~   2°C
lower than the
room temperature
OFF
ON
HE
A
HEA
T
DR
DR
Y F
AN
AN
CO
OL
COOL
CHECK
TE
M
P
AU
T
AUT
O
AUT
AUT
O
FA
N
AN
AU
T
AUT
O
RESET
CLOCK
AIR
 S
W
IN
G
OFF
CANC
EL
1
2
3
TI
M
ER
OFF/
ON
AU
TO
MANU
AL
QU
IET
POWERFUL
ON
SE
T
FAN SPEED
MO
DE
2
3
5
1
6
4
40
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
Page of 87
Display

Click on the first or last page to see other CS-W7CKP / CU-W7CKP5 / CS-W9CKP / CU-W9CKP5 / CS-W12CKP / CU-W12CKP5 service manuals if exist.