DOWNLOAD Panasonic CS-TE9HKE / CS-TE12HKE / CU-TE9HKE / CU-TE12HKE Service Manual ↓ Size: 7.1 MB | Pages: 61 in PDF or view online for FREE

Model
CS-TE9HKE CS-TE12HKE CU-TE9HKE CU-TE12HKE
Pages
61
Size
7.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-te9hke-cs-te12hke-cu-te9hke-cu-te12hke.pdf
Date

Panasonic CS-TE9HKE / CS-TE12HKE / CU-TE9HKE / CU-TE12HKE Service Manual ▷ View online

37
14 Servicing Mode
14.1. Auto OFF/ON Button
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to
operate air conditioner with limited function if remote control is misplaced or malfunction.
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A “beep”
sound will occur at the fifth seconds, in order to identify the starting of Test Run operation (Forced cooling operation). Within 5
minutes after Forced cooling operation start, the Auto OFF/ON button is pressed for more than 5 seconds. A 2 “beep” sounds
will occur at the fifth seconds, in order to identify the starting of Forced heating operation.
The Auto OFF/ON button may be used together with remote control to set / change the advance setting of air conditioner
operation.
3. REMOTE CONTROL NUMBER SWITCH MODE
The Remote Control Number Switch Mode will be activated if the Auto OFF/ON button is pressed continuously for more than
11 seconds (3 “beep” sounds will occur at 11th seconds to identify the Remote Control Number Switch Mode is in standby
condition) and press any button at remote control to transmit and store the desired transmission code to the EEPROM.
For transmission code selection explanation, please refer to “Select Remote Control Transmission Code”.
4. REMOTE CONTROL RECEIVING SOUND OFF/ON MODE
The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed continuously for
more than 16 seconds (4 “beep” sounds will occur at 16th seconds to identify the Remote Control Receiving Sound Off/On
Mode is in standby condition) and press “AC Reset” button and then press “Check” button at remote control.
Press “Auto OFF/ON button” to toggle remote control receiving sound.
- Short “beep”: Turn OFF remote control receiving sound.
- Long “beep”: Turn ON remote control receiving sound.
After Auto OFF/ON Button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON Mode is
restarted.
14.2. Select Remote Control Transmission Code
• There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal interference
when there are 2 or more indoor units installed nearby together.
• To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
38
14.3. Remote Control Button
14.3.1.
SET BUTTON
• To check current remote control transmission code
- Press for more than 10 seconds.
• To change the air quality sensor sensitivity
- Press and release with pointer.
- Press the Timer Decrement button to select sensitivity:
1. Low Sensitivity
2. Standard (Default)
3. Hi Sensitivity
- Confirm setting by pressing Timer Set button, a “Beep” sound will be heard. LCD returns to original display after 2 seconds.
- LCD returns to original display if remote control does not operate for 30 seconds.
14.3.2.
CLOCK BUTTON
• To change the remote control’s time format
- Press for more than 5 seconds.
14.3.3.
RESET (RC)
• To clear and restore the remote control setting to factory default
- Press once to clear the memory.
14.3.4.
RESET (AC)
• To restore the unit’s setting to factory default
- Press once to restore the unit’s setting.
14.3.5.
TIMER 
• To change indoor unit indicator’s LED intensity
- Press continuously for 5 seconds.
14.3.6.
TIMER 
• To change remote control display from Degree Celsius to Degree Fahrenheit.
- Press continuously for 10 seconds.
Remote Control Printed Circuit Board
Jumper A (J-A)
Jumper B (J-B)
Remote Control No.
Short
Open
A (Default)
Open
Open
B
Short
Short
C
Open
Short
D
39
15 Troubleshooting Guide
15.1. Refrigeration Cycle System
In order to diagnose malfunctions, make sure that there are no
electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the
refrigeration cycle depends on various conditions, the standard
values for them are shown in the table on the right.
40
15.1.1.
Relationship between the condition of the air conditioner and pressure and electric
current
• Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.
Cooling Mode
Heating Mode
Low Pressure
High Pressure
Electric current 
during operating
Low Pressure
High Pressure
Electric current 
during operating
Condition of the air 
conditioner
Insufficient refrigerant 
(gas leakage)
Clogged capillary tube 
or Strainer
Short circuit in the
indoor unit
Heat radiation deficiency   
of the outdoor unit
Inefficient compression
Page of 61
Display

Click on the first or last page to see other CS-TE9HKE / CS-TE12HKE / CU-TE9HKE / CU-TE12HKE service manuals if exist.