Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Simplified Service Manual ▷ View online
9.3.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
•
•
•
•
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
—
—
O
O
O
O
O
—
—
—
Tab (rpm)
PSHi
SHi
Hi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
CS-ME10DTEG
900
900
830
790
740
690
640
590
530
370
CS-E15DTEW
1070
1070
1000
940
870
800
730
680
630
370
CS-E18DTEW
1110
1110
1040
970
920
850
790
740
630
370
[Heating]
Remote Control
—
—
O
O
O
O
O
—
—
—
Tab (rpm)
PSHi
SHi
Hi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
CS-ME10DTEG
900
900
830
780
730
680
630
590
530
370
CS-E15DTEW
1080
1080
1010
920
830
730
630
590
530
300
CS-E18DTEW
1110
1110
1050
950
860
770
680
630
540
370
65
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
B. Indoor Fan Control
i. Indoor fan control operation outline
1. Cooling / Dry
66
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
2. Heating
ii. Auto Fan Speed
1. Cooling
1. Cooling
Model
No. A
No. B
No. C
Powerful Program
CS-ME10DTEG
790
810
830
CS-E15DTEW
940
960
980
CS-E18DTEW
990
1010
1030
Normal Program
CS-ME10DTEG
730
750
770
CS-E15DTEW
880
900
920
CS-E18DTEW
930
950
970
Quiet Program
CS-ME10DTEG
710
730
750
CS-E15DTEW
860
880
900
CS-E18DTEW
910
930
950
67
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
2. Heating
Note:
a. UP:
a. UP:
•
•
•
•
If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm.
•
•
•
•
If move from Maximum, the fan speed no change.
•
•
•
•
In up zone, 10 rpm is added for every 10s until Maximum 1,520 rpm.
b. DOWN:
•
•
•
•
The fan speed will be decreased one step every 10 sec. until Minimum 1,270 rpm.
c. Current Output Fixed:
•
•
•
•
Maintain at present fan speed.
d. Instantaneous Maximum:
•
•
•
•
Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
C. Fan Motor Control
1. Motor specification
Phase control motor
D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follows.
The odor status is arranged as below and it is shifted as follows.
* When COMP is ON
1
→
2
→
3
(Shift to 4 when COMP is OFF)
* When COMP is OFF
4
→
5
→
6
→
7
→
6
←→
7
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
68
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
Click on the first or last page to see other CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW service manuals if exist.