Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Simplified Service Manual ▷ View online
1 Features
3
2 About Lead Solder (PbF)
4
2.1.
DISTINCTION OF PbF P.C. BOARD
4
2.2.
CAUTION
4
3 Functions
5
3.1.
Wall Type
5
3.2.
Duct Type
8
CS-ME7DKEG CS-ME10DD3EG
CS-ME10DTEG CS-E15DB4EW
CS-ME10DTEG CS-E15DB4EW
CS-ME7DKRG CS-ME7DKDG
CS-E9DKEW CS-E9DKRW
CS-E9DKDW CS-E12DKEW
CS-E12DKRW CS-E12DKDW
CS-E15DKEW CS-E15DKRW
CS-E15DKDW CS-E18DKEW
CS-E18DKRW CS-E18DKDW
CS-E15DD3EW CS-E18DD3EW
CS-E15DTEW CS-E18DTEW
CS-E18DB4EW
CS-E9DKEW CS-E9DKRW
CS-E9DKDW CS-E12DKEW
CS-E12DKRW CS-E12DKDW
CS-E15DKEW CS-E15DKRW
CS-E15DKDW CS-E18DKEW
CS-E18DKRW CS-E18DKDW
CS-E15DD3EW CS-E18DD3EW
CS-E15DTEW CS-E18DTEW
CS-E18DB4EW
3.3.
Ceiling Floor Type
11
3.4.
Mini-Cassette Type
13
4 Product Specifications
15
4.1.
Wall Type
15
4.2.
Duct Type
16
4.3.
Ceiling Floor Type
17
4.4.
Mini-Cassette Type
18
Multi Air Conditioner
Please file and use this manual together with the Service Manuals for the following models:
Indoor unit models: CS-ME7CKPG, CS-ME10CKPG, CS-ME12CKPG, CS-ME14CKPG and CS-ME18CKPG;
Outdoor unit models: CU-2E15CBPG, CU-2E18CBPG, CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0209005C2); Indoor unit models: CS-ME7CB1P, CS-ME10CB1P, CS-ME12CB1P, CS-ME14CB1P, CS-
ME10CD3P and CS-ME14CD3P; Outdoor unit models: CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0312001A8)
Indoor unit models: CS-ME7CKPG, CS-ME10CKPG, CS-ME12CKPG, CS-ME14CKPG and CS-ME18CKPG;
Outdoor unit models: CU-2E15CBPG, CU-2E18CBPG, CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0209005C2); Indoor unit models: CS-ME7CB1P, CS-ME10CB1P, CS-ME12CB1P, CS-ME14CB1P, CS-
ME10CD3P and CS-ME14CD3P; Outdoor unit models: CU-3E23CBPG and CU-4E27CBPG (Order No.
RAC0312001A8)
CONTENTS
Page
Page
Order No. RAC0503011C2
4.5.
Outdoor units: CU-2E15CBPG / CU-2E18CBPG
19
4.6.
Outdoor units: CU-3E23CBPG / CU-4E27CBPG
20
5 Dimensions
24
5.1.
Wall Type
24
5.2.
Duct Type
26
5.3.
Ceiling Floor Type
28
5.4.
Mini-Cassette Type
29
6 Refrigeration Cycle Diagram
30
6.1.
CU-2E15CBPG / CU-2E18CBPG
30
6.2.
CU-3E23CBPG / CU-4E27CBPG
31
7 Block Diagram
32
8 Wiring Diagram
33
8.1.
Wall Type
33
8.2.
Duct Type
34
8.3.
Ceiling Floor Type
35
8.4.
Mini-Cassette Type
36
9 Operation Details
37
9.1.
Wall Type
37
9.2.
Duct Type
54
9.3.
Ceiling Floor Type
60
9.4.
Mini-Cassette Type
74
10 Self Diagnosis Display
88
10.1. Breakdown Self Diagnosis Function (Three Digits
Alphanumeric Code)
88
10.2. Error Code
89
11 Installation Instructions
93
11.1. Wall Type
93
11.2. Duct Type
101
11.3. Ceiling Floor Type
110
11.4. Mini-Cassette Type
116
12 Operating Instructions
125
13 Installation and Servicing Air Conditioner Using R410A
139
13.1. OUTLINE
139
13.2. TOOLS FOR INSTALLING/SERVICING REFRIGERANT
PIPING
140
13.3. REFRIGERANT PIPING WORK
144
13.4. INSTALLATION, TRANSFERRING, SERVICING
147
14 Disassembly of Parts
151
14.1. Wall Type
151
14.2. Duct Type
153
14.3. Ceiling Floor Type
155
14.4. Mini-Cassette Type
156
15 Technical Data
158
15.1. Operation Characteristics
158
16 Electronic Circuit Diagram
164
16.1. Wall Type
164
16.2. Duct Type
171
16.3. Ceiling Floor Type
173
16.4. Mini-Cassette Type
179
17 Exploded View and Replacement Parts List
186
17.1. Wall Type
186
17.2. Duct Type
192
17.3. Ceiling Floor Type
194
17.4. Mini-Cassette Type
196
2
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
1 Features
•
•
•
•
Product
−
−
−
−
A single OUTDOOR unit enable air conditioning of up to two separate rooms for CU-2E15CBPG and CU-2E18CBPG.
−
−
−
−
A single OUTDOOR unit enable air conditioning of up to three separate rooms for CU-3E23CBPG.
−
−
−
−
A single OUTDOOR unit enable air conditioning of up to four separate rooms for CU-4E27CBPG.
Remarks for CU-2E15CBPG / CU-2E18CBPG:
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (shown in the above table.)
Example: The below indoor units combination is possible to connect CU-2E15CBPG. (Total nominal capacity of indoor
units is between 4.4 kW and 5.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME7DKEG and one CS-E9DKEW. (Total nominal cooling capacity is 5.0 kW.)
Example: The below indoor units combination is possible to connect CU-2E15CBPG. (Total nominal capacity of indoor
units is between 4.4 kW and 5.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME7DKEG and one CS-E9DKEW. (Total nominal cooling capacity is 5.0 kW.)
Remarks for CU-3E23CBPG / CU-4E27CBPG:
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (shown in the above table.)
Example: The below indoor units combination is possible to connect CU-3E23CBPG. (Total nominal capacity of indoor
units is between 5.0 kW and 10.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME12DKEG. (Total nominal cooling capacity is 9.6 kW.)
Example: The below indoor units combination is possible to connect CU-3E23CBPG. (Total nominal capacity of indoor
units is between 5.0 kW and 10.0 kW)
1) Two CS-ME7DKEG only. (Total nominal cooling capacity is 4.4 kW.)
2) One CS-ME12DKEG. (Total nominal cooling capacity is 9.6 kW.)
3
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
•
•
•
•
Serviceability
−
−
−
−
Self diagnosis
−
−
−
−
Test Run at both Cooling and Heating rated frequency
•
•
•
•
Built-in drain pump (Cassette and Duct type)
−
−
−
−
A drain pump is built in.
The pipe can rise to 200m above the drain outlet.
The pipe can rise to 200m above the drain outlet.
2 About Lead Solder (PbF)
2.1. DISTINCTION OF PbF P.C. BOARD
P.C. Boards (manufactured) using lead free solder will have a PbF stamp on the P.C. Board.
2.2. CAUTION
•
•
•
•
Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70 °F (30 - 40 °C) higher.
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
Please use a high temperature solder iron and set it to 700 ± 20 °F (370 ± 10 °C).
•
•
•
•
Pb free solder will tend to slash when heated too high (about 1100 °F/ 600°C).
If you must use Pb solder, please completely all of the Pb free solder on the pins or solder area before applying Pb solder. If
this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
If you must use Pb solder, please completely all of the Pb free solder on the pins or solder area before applying Pb solder. If
this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
4