DOWNLOAD Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Service Manual ↓ Size: 40.7 MB | Pages: 127 in PDF or view online for FREE

Model
CS-ME10DD3EG CS-ME10DTEG CS-E15DB4EW CS-ME7DKDG CS-E9DKDW CS-E12DKDW CS-E15DKDW CS-E18DKDW CS-E15DD3EW CS-E18DD3EW CS-E15DTEW CS-E18DTEW CS-E18DB4EW
Pages
127
Size
40.7 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-me10dd3eg-cs-me10dteg-cs-e15db4ew-cs-me7dkdg-cs.pdf
Date

Panasonic CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW Simplified Service Manual ▷ View online

9.1.1.6. Automatic Operation
This mode can be set using remote control and the operation is decided by remote control setting temperature, indoor intake air
temperature and outdoor air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to detect
the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.
Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 3 hours.
Remote Control Setting Temperature (°C)
T1
T2
T3
16 ~ 18
+10
-3
-5
19 ~ 22
+8
-3
-7
23 ~ 26
+7
-3
-7
27 ~ 30
+6
-3
-8
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
verse.
Operation Mode change from
Temperature shifts (°C)
Cooling/Soft Dry
Heating
-2
Heating
Cooling/Soft Dry
+2
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 - 3 = 22; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
41
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
Notes:
9.1.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
     • 
• 
• 
• 
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
O
O
O
O
O
Tab (rpm)
PSHi
SHi
Hi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
CS-ME7DKEG
1320
1320
1280
1210
1040
970
920
860
720
710
CS-E9DKEW
1320
1320
1280
1210
1040
970
920
860
720
710
CS-E12DKEW
1460
1460
1420
1320
1220
1120
1020
950
720
710
CS-E15DKEW
1500
1500
1460
1350
1240
1130
1020
950
720
710
CS-E18DKEW
1540
1540
1450
1340
1240
1140
1040
980
770
640
[Heating]
Remote Control
O
O
O
O
O
Tab (rpm)
PSHi
SSHi
SHi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
CS-ME7DKEG
1440
1440
1400
1290
1170
1060
950
870
720
710
CS-E9DKEW
1440
1440
1400
1290
1170
1060
950
870
720
710
CS-E12DKEW
1540
1540
1500
1400
1290
1180
1070
990
720
710
CS-E15DKEW
1570
1570
1560
1430
1310
1190
1070
990
720
710
CS-E18DKEW
1640
1640
1580
1470
1350
1230
1110
1040
400
300
 1. Refer to the CS-ME7DKEG column for CS-ME7DKRG and CS-ME7DKDG.
 2. Refer to the CS-E9DKEW column for CS-E9DKRW and CS-E9DKDW.
 3. Refer to the CS-E12DKEW column for CS-E12DKRW and CS-E12DKDW.
 4. Refer to the CS-E15DKEW column for CS-E15DKRW and CS-E15DKDW.
 5. Refer to the CS-E18DKEW column for CS-E18DKRW and CS-E18DKDW.
42
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
B. Indoor Fan Control
i. Indoor fan control operation outline
 1. Cooling / Dry
43
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
 2. Heating
ii. Auto Fan Speed
 1. Cooling
Model
No. A
No. B
No. C
Powerful Program
CS-ME7DKEG, CS-E9DKEW
1110
1130
1150
CS-E12DKEW
1230
1250
1270
CS-E15DKEW
1300
1320
1340
CS-E18DKEW
1390
1410
1430
Normal Program
CS-ME7DKEG, CS-E9DKEW
1050
1070
1090
CS-E12DKEW
1170
1190
1210
CS-E15DKEW
1240
1260
1280
CS-E18DKEW
1330
1350
1370
Quiet Program
CS-ME7DKEG, CS-E9DKEW
1030
1050
1070
CS-E12DKEW
1150
1170
1190
CS-E15DKEW
1220
1240
1260
CS-E18DKEW
1310
1330
1350
     • 
• 
• 
• 
Refer to the CS-ME7DKEG column for CS-ME7DKRG and CS-ME7DKDG.
     • 
• 
• 
• 
Refer to the CS-E9DKEW column for CS-E9DKRW and CS-E9DKDW.
     • 
• 
• 
• 
Refer to the CS-E12DKEW column for CS-E12DKRW and CS-E12DKDW.
     • 
• 
• 
• 
Refer to the CS-E15DKEW column for CS-E15DKRW and CS-E15DKDW.
     • 
• 
• 
• 
Refer to the CS-E18DKEW column for CS-E18DKRW and CS-E18DKDW.
44
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
Page of 127
Display

Click on the first or last page to see other CS-ME10DD3EG / CS-ME10DTEG / CS-E15DB4EW / CS-ME7DKDG / CS-E9DKDW / CS-E12DKDW / CS-E15DKDW / CS-E18DKDW / CS-E15DD3EW / CS-E18DD3EW / CS-E15DTEW / CS-E18DTEW / CS-E18DB4EW service manuals if exist.