Panasonic CS-HE9NKD / CS-HE12NKD / CU-HE9NKD / CU-HE12NKD Service Manual ▷ View online
9
Type
Cross-flow
Fan
Material
ASG20K1
Motor Type
Transistor (8-poles)
Input Power
W
47.3
Output Power
W
40
Cool rpm
760
QLo
Heat rpm
950
Cool rpm
830
Lo
Heat rpm
1010
Cool rpm
1040
Me
Heat rpm
1150
Cool rpm
1260
Hi
Heat rpm
1300
Cool rpm
1320
Indoor Fan
Speed
SHi
Heat rpm
1340
Type
Propeller
Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
-
Output Power
W
40
Cool rpm
840
Outdoo
r Fa
n
Speed Hi
Heat rpm
820
Moisture Removal
L/h (Pt/h)
2.0 (4.2)
Cool m
3
/min (ft
3
/min) 6.4
(226)
QLo
Heat m
3
/min (ft
3
/min) 8.7
(307)
Cool m
3
/min (ft
3
/min) 7.5
(265)
Lo
Heat m
3
/min (ft
3
/min) 9.4
(332)
Cool m
3
/min (ft
3
/min) 9.8
(346)
Me
Heat m
3
/min (ft
3
/min) 11.0
(388)
Cool m
3
/min (ft
3
/min) 12.5
(440)
Hi
Heat m
3
/min (ft
3
/min) 12.8
(450)
Cool m
3
/min (ft
3
/min) 13.1
(463)
Indoor
Airflow
SHi
Heat m
3
/min (ft
3
/min) 13.3
(470)
Cool m
3
/min (ft
3
/min) 31.0
(1090)
Outdoor
Airflow
Hi
Heat m
3
/min (ft
3
/min) 30.2
(1070)
Control Device
Expansion Valve
Refrigerant Oil
cm
3
RB68A or Freol Alpha 68M (400)
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 970 (34.2)
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 542 (21-11/32)
Width (I/D / O/D)
mm (inch)
870 (34-9/32) / 780 (30-23/32)
Dimension
Depth (I/D / O/D)
mm (inch)
214 (8-7/16) / 289 (11-13/32)
Weight
Net (I/D / O/D)
kg (lb)
9 (20) / 31 (68)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5 (16.4)
Length Range (min – max)
m (ft)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height Different
m (ft)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
10
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 24 x 17
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
36.4 x 504 x 725:713
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
Dry Bulb
Wet Bulb
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
-
Indoor
Operation
Range
Heating
Minimum 16
-
Maximum 43
26
Cooling
Minimum -15
-
Maximum 24
18
Outdoor
Operation
Range
Heating
Minimum -15
-
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
11
3. Features
Inverter Technology
o
Wider output power range
o
Energy
saving
o
Quick
Cooling
o
Quick
Heating
o
More precise temperature control
Air Purifying System with nanoe-G
o
Deactivates and removes bacterial, viruses and mould
Environment Protection
o
Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
o
Long piping up to 15 meters (0.75 ~ 1.75HP)
Easy to use remote control
Quality Improvement
o
Random auto restart after power failure for safety restart operation
o
Gas
leakage
protection
o
Prevent compressor reverse cycle
o
Inner protector to protect Compressor
o
Noise prevention during soft dry operation
Operation Improvement
o
Quiet mode to reduce the indoor unit operating sound
o
Powerful mode to reach the desired room temperature quickly
o
24-hour timer setting
Serviceability Improvement
o
Breakdown Self Diagnosis function
12
4. Location of Controls and Components
4.1 Indoor
Unit
4.2 Outdoor
Unit
4.3 Remote
Control