37 
d.  AUTO COMFORT button is pressed. 
e.  ECONAVI button is pressed. 
f.  Mild Dry Cooling button is pressed. 
2  When quiet operation is stopped, operation is shifted to normal operation with previous setting. 
3  When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed. 
4  When operation mode is changed, quiet operation is shifted to quiet operation of the new mode. 
5  During quiet operation, if timer “on” activates, quiet operation maintains. 
6  After off, when on back, quiet operation is not memorised. 
 
C. Control contents 
1  Fan speed is changed from normal setting to quiet setting of respective fan speed. 
This is to reduce sound of Hi, Me, Lo for 3dB (some models more than 3dB). 
2  Fan speed for quiet operation is reduced from setting fan speed. 
 
12.6  Quiet operation (Heating) 
A. Purpose 
To provide quiet heating operation compare to normal operation. 
 
B. Control condition 
a.  Quiet operation start condition 
o
 
When “POWERFUL/QUIET” button at remote control is pressed. 
POWERFUL/QUIET LED illuminates. 
 
b.  Quiet operation stop condition 
1  When one of the following conditions is satisfied, quiet operation stops: 
a.  POWERFUL/QUIET button is pressed again. 
b.  Stop by OFF/ON switch. 
c.  Timer “off” activates. 
d.  AUTO COMFORT button is pressed. 
e.  ECONAVI button is pressed. 
f.  Mild Dry Cooling button is pressed. 
2  When quiet operation is stopped, operation is shifted to normal operation with previous setting. 
3  When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed. 
4  When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except fan 
only mode. 
5  During quiet operation, if timer “on” activates, quiet operation maintains. 
6  After off, when on back, quiet operation is not memorised. 
 
C. Control contents 
a.  Fan Speed manual 
1  Fan speed is changed from normal setting to quiet setting of respective fan speed. 
This is to reduce sound of Hi, Me, Lo for 3dB. 
2  Fan speed for quiet operation is reduced from setting fan speed. 
b.  Fan Speed manual 
Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger. 
 
12.7 Powerful Mode Operation 
š  When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft 
Dry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the 
setting temperature quickly. 
 
12.8 Timer Control 
š  There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time. 
š  If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence. 
12.8.1 ON 
Timer 
Control 
š  ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than 
the setting time. 
This is to provide a comfortable environment when reaching the set ON time. 
38 
š  60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to 
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting 
time. 
š  From the above judgment, the decided operation will start operate earlier than the set time as shown below. 
 
 
 
12.8.2  OFF Timer Control 
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time. 
 
12.9 Auto Restart Control 
1  When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within 
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be 
selected randomly) after power supply resumes. 
2  This type of control is not applicable during ON/OFF Timer setting. 
3  This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board. 
12.10   Indication Panel  
LED POWER 
TIMER 
POWERFUL  QUIET  ECONAVI 
AUTO 
COMFORT 
nanoe-G 
Color Green 
Orange 
Orange 
Green  Green 
Green 
Blue 
Light ON  Operation ON  Timer Setting ON 
POWERFUL Mode 
ON 
QUIET Mode 
ON 
ECONAVI ON 
AUTO COMFORT 
ON 
nanoe-G ON 
Light OFF  Operation OFF Timer Setting OFF 
POWERFUL Mode 
OFF 
QUIET Mode 
OFF 
ECONAVI OFF
AUTO COMFORT 
OFF 
nanoe-G OFF
 
Note: 
š  If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation 
mode judgment, or ON timer sampling. 
š  If Timer LED is blinking, there is an abnormality operation occurs. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
39 
12.11 nanoe-G 
Operation 
š  This operation provides clean air by producing great amount of negative ions and distribute through the 
discharge airflow to capture or deactivate molds, bacteria or viruses. 
 
š  nanoe-G operation start condition 
o
  During unit running at any operation mode, if nanoe-G operation is activated, combination operation 
(operation mode + nanoe-G operation) starts. 
o
  During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts. 
 
š  nanoe-G operation stop condition 
o
  When OFF/ON button is pressed to stop the operation. 
o
  When nanoe-G button is pressed. 
o
  When OFF Timer activates. 
 
š  nanoe-G operation pause condition 
o
  When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after 
indoor fan restarts. 
o
  When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C 
continuously for 30 minutes. 
 
š Indoor 
fan 
control 
o
  During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode. 
However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution, 
nanoe-G system disabled when fan speed < 500 rpm. 
o
  During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan 
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan 
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation. 
 
š  Airflow direction control 
o
  During any operation mode combines with nanoe-G operation, airflow direction follows respective operation 
mode. 
o
  During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no 
signal is sent to the unit and no change on remote control display. 
 
š Timer 
control 
o
  When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G 
operation status. 
o
  When ON Timer activates during any operation, no change on current operation. 
o
  When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status 
is saved. 
 
š Indicator 
o
  When nanoe-G starts, nanoe-G indicator ON. 
 
š  Remote Control Receiving Sound 
o
 Normal 
Operation 
 
Î
 nanoe-G Operation   
     : Beep 
o
 Nanoe-G 
Operation   
Î
 Normal Operation 
 
     : Beep 
o
 
 
Stop 
   Î nanoe-G individual Operation      : Beep 
o
  Nanoe-G individual Operation  Î Stop  
 
 
     : Long Beep 
 
š Power 
failure 
o
  During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual 
operation resumes immediately. 
o
  During combination operation, if power failure occurs, after power resumes, combination operation resume 
immediately. 
o
  nanoe-G operation status is not memorized after OFF the unit. After OFF the unit, when the operation is ON 
again, air conditioner operates without nanoe-G operation. 
 
 
 
 
 
 
40 
š nanoe-G 
check 
mode 
o
  To enable nanoe-G check mode, during nanoe-G operation ON: 
 
 
 
o
  If there is abnormal discharge, nanoe-G indicator blinks immediately. 
 
š  Error detection control 
When nanoe-G indicator blinks, it indicates error listed below: 
o
  nanoe-G connector at main PCB open 
ƒ
 Judgment 
method 
š  During nanoe-G operation, nanoe-G connector at main PCB is opened. 
ƒ
 Troubleshooting 
method 
š  Connect the connector or stop operation to cancel the blinking 
o
  Abnormal discharge error 
ƒ
 Judgment 
method 
š  During nanoe-G operation, the nanoe-G system has abnormal discharge due to short-circuit caused 
by water or dust adhesion and so forth, with Lo-feedback voltage (at microcontroller). 
š  When abnormal discharge occurred, every 30 minutes the unit supplies power to the nanoe-G 
system. 
š  When abnormal discharge occurs for 24 times continuously, nanoe-G indicator blinks. 
o
 Troubleshooting 
method 
ƒ
  Press nanoe-G button or OFF/ON button to stop the operation and check the nanoe-G connector at PCB. 
ƒ
  After that, press nanoe-G button again to confirm the nanoe-G indicator do not blinks. 
ƒ
  The 24 timer counter will be clear after 10 minutes of normal operation or when operation stops. 
o
  Error reset method 
ƒ
  Press OFF/ON button to OFF the operation. 
ƒ
  Press AUTO OFF/ON button at indoor unit to OFF the operation. 
ƒ
  OFF Timer activates 
ƒ
  Power supply reset. 
 
o
  nanoe-G breakdown error 
ƒ
 Judgment 
method 
š  Hi-feedback voltage (at microcontroller) supplied to the nanoe-G system when nanoe-G operation is 
OFF; nanoe-G breakdown error show immediately. 
š  It is due to indoor PCB or nanoe-G high voltage power supply damage. 
š  Operations except nanoe-G continue. Both Timer indicator and nanoe-G indicator blink. 
 