Sony HT-1900DP / STR-K1900P Service Manual ▷ View online
SERVICE MANUAL
Sony Corporation
Audio Group
Published by Sony Engineering Corporation
Published by Sony Engineering Corporation
Canadian Model
E Model
FM STEREO FM-AM RECEIVER
9-877-996-02
2004J16-1
© 2004.10
© 2004.10
Ver 1.1 2004.10
SPECIFICATIONS
STR-K1900P
• STR-K1900P is the tuner and the amplifier
section in HT-1900DP.
section in HT-1900DP.
Manufactured under license from Dolby Laboratories.
“Dolby”, “Pro Logic” and the double-D symbol are trademarks
of Dolby Laboratories.
“DTS” and “DTS Digital Surround” are registered trademarks
of Digital Theater Systems, Inc.
“Dolby”, “Pro Logic” and the double-D symbol are trademarks
of Dolby Laboratories.
“DTS” and “DTS Digital Surround” are registered trademarks
of Digital Theater Systems, Inc.
Amplifier section
Power Output
1)
(6 ohms 1 kHz, THD 0.7%)
0.7%)
FRONT
2)
: 60 W/ch
CENTER
2)
: 60 W
SURR
2)
: 60 W/ch
(6 ohms 100 Hz, THD
SUB WOOFER
2)
: 60 W
(6 ohms 1 kHz, THD 10%)
10%)
FRONT
2)
: 80 W/ch
CENTER
2)
: 80 W
SURR
2)
: 80 W/ch
(6 ohms 100 Hz, THD
SUB WOOFER
2)
: 80 W
(6 ohms 1 kHz, THD 10%)
FRONT
2)
: 70 W/ch
CENTER
2)
: 70 W
SURR
2)
: 70 W/ch
(6 ohms 100 Hz, THD 10%)
SUB WOOFER
2)
: 70 W
1) Measured under the following conditions:
Area code
Power requirements
CND, MX
120 V AC, 60 Hz
E51
240 V AC, 50 Hz
2) Depending on the sound field settings and the
source, there may be no sound output.
Inputs (Analog)
DVD, VIDEO
Sensitivity: 800 mV
Impedance: 50 kiloohms
FM tuner section
Tuning range
87.5 - 108.0 MHz
Antenna
FM wire antenna
Antenna terminals
75 ohms, unbalanced
Intermediate Frequency
10.7 MHz
Reproduction frequency range:
28
− 20,000 Hz
Tone
Gain levels
±6 dB, 1 dB step
Inputs (Digital)
DVD (Coaxial)
Sensitivity:
−
Impedance: 75 ohms
VIDEO (Optical)
Sensitivity:
−
Impedance:
−
— Continued on next page —
2
STR-K1900P
AM tuner section
Tuning range
Models of area code CND
With 10-kHz tuning scale: 530 - 1,710 kHz
Models of area code CND
With 10-kHz tuning scale: 530 - 1,710 kHz
3)
With 9-kHz tuning scale: 531 - 1,710 kHz
3)
Models of area code E51
With 10-kHz tuning scale: 530 - 1,610 kHz
With 10-kHz tuning scale: 530 - 1,610 kHz
3)
With 9-kHz tuning scale: 531 - 1,602 kHz
3)
Models of area code MX
With 10-kHz tuning scale: 530 - 1,610 kHz
Antenna
With 10-kHz tuning scale: 530 - 1,610 kHz
Antenna
Loop antenna
Intermediate Frequency
450 kHz
3) You can change the AM tuning scale to 9 kHz or
10 kHz. After tuning in any AM station, turn off the
receiver. While holding down PRESET TUNING +
or TUNING +, press ?/1. All preset stations will be
erased when you change the tuning scale. To reset
the scale to 10 kHz (or 9 kHz), repeat the procedure.
receiver. While holding down PRESET TUNING +
or TUNING +, press ?/1. All preset stations will be
erased when you change the tuning scale. To reset
the scale to 10 kHz (or 9 kHz), repeat the procedure.
General
Power requirements
Area code
Power requirements
CND, MX
120 V AC, 60 Hz
E51
120/220/240 V AC, 50/60 Hz
Power consumption (during standby mode)
0.3 W
Dimensions (w/h/d) (Approx.)
430
× 145 × 301.5 mm
(17
× 5 6/8 × 11 7/8 inches)
including projecting parts
and controls
and controls
Ma
•
Abbreviation
CND : Canadian model
E51 : Chilean and Peruvian models
MX : Mexican model
E51 : Chilean and Peruvian models
MX : Mexican model
ss (Approx.)
6.5 kg (14 lb 6 oz)
Power consumption
CND
Area code
Power consumption
E51, MX
150 W
150 W
Design and specifications are subject to change without notice.
TABLE OF CONTENTS
1.
GENERAL
...................................................................
4
2.
TEST MODE
...............................................................
8
3.
DIAGRAMS
3-1.
Block Diagrams – MAIN Section – ................................ 10
– Display/Power Section – .............................................. 11
– Display/Power Section – .............................................. 11
3-2.
Printed Wiring Board – DIGITAL Board (Side A) – ....... 12
3-3.
Printed Wiring Board – DIGITAL Board (Side B) – ....... 13
3-4.
Schematic Diagram – DIGITAL Board (1/2) – ............... 14
3-5.
Schematic Diagram – DIGITAL Board (2/2) – ............... 15
3-6.
Printed Wiring Board – MAIN Section – ........................ 16
3-7.
Schematic Diagram – MAIN Section (1/2) – .................. 17
3-8.
Schematic Diagram – MAIN Section (2/2) – .................. 18
3-9.
Printed Wiring Board – SUB WOOFER Board – ........... 19
3-10. Schematic Diagram – SUB WOOFER Board – .............. 19
3-11. Printed Wiring Board – POWER Section – ..................... 20
3-12. Schematic Diagram – POWER Section – ....................... 21
3-13. Printed Wiring Board – Front Panel Section – ................ 22
3-14. Schematic Diagram – Front Panel Section – ................... 23
3-11. Printed Wiring Board – POWER Section – ..................... 20
3-12. Schematic Diagram – POWER Section – ....................... 21
3-13. Printed Wiring Board – Front Panel Section – ................ 22
3-14. Schematic Diagram – Front Panel Section – ................... 23
4.
EXPLODED VIEWS
4-1.
Front Panel Section ......................................................... 30
4-2.
Chassis Section ................................................................ 31
5.
ELECTRICAL PARTS LIST
.................................. 32
3
STR-K1900P
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
UNLEADED SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40 °C higher
than ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350
°C.
Caution: The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscou-s (sticky, less prone to flow)
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
also be added to ordinary solder.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK
0
OR DOTTED LINE
WITH MARK
0
ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE
0
SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
MODEL IDENTIFICATION
– BACK PANEL –
– BACK PANEL –
Parts No.
• Abbreviation
CND : Canadian model
E51 : Chilean and Perurian models
MX : Mexican model
CND : Canadian model
E51 : Chilean and Perurian models
MX : Mexican model
MODEL
PARTS No.
MX model
4-252-087-2
s
CND model
4-252-087-3
s
E51 model
4-252-088-8
s
4
STR-K1900P
SECTION 1
GENERAL
This section is extracted
from instruction manual.
from instruction manual.
Main unit
$)'EXWWRQLQGLFDWRU8
$0wd
',00(53
',63/$<2
'LVSOD\5
'9'wg
(17(5qs
)0wf
)002'(wa
,QSXWEXWWRQVqj
,138702'(qd
,5UHFHSWRU4
',00(53
',63/$<2
'LVSOD\5
'9'wg
(17(5qs
)0wf
)002'(wa
,QSXWEXWWRQVqj
,138702'(qd
,5UHFHSWRU4
0$,10(18qh
0$67(592/80(±qa
0$67(592/80(±qa
0(025<w;
029,(EXWWRQLQGLFDWRU9
029,(EXWWRQLQGLFDWRU9
08/7,&+$11(/'(&2',1*
LQGLFDWRU6
086,&EXWWRQLQGLFDWRUq;
3+21(6MDFNws
35(6(7781,1*±qk
35(6(7781,1*±qk
781,1*±ql
9,'(2wh
9,'(2wh
&+EXWWRQLQGLFDWRU7
±qf
!qg
?/1SRZHU1
!qg
?/1SRZHU1
$/3+$%(7,&$/25'(5
$/
0=
180%(56$1'6<0%2/6
4
2 3
5
1
qj
wa
ql
qk
w;
qdqs
qf
qa
7
6
8 9 q;
ws
qg
qh
wh
wg
wf
wd