CARE & CLEANING
•  Wipe the unit gently with a soft, dry 
cloth.
•  It is recommended to clean the air 
fi lters once every 2 weeks.
•  Purchase the replacement fi lter if it 
is damaged.
  Part no.: CWD001144
INDOOR UNIT
AIR FILTER
•  It is recommended to clean the fi lter 
every 6 months.
•  Replace the fi lter every 3 years or 
purchase the replacement fi lter if it 
is damaged. 
  Part no.: CZ-SA13P
SUPER ALLERU-BUSTER
•  This inspection is recommended 
before operating the air conditioner 
at every season.
•  Check if the remote control batteries 
needed to be replaced.
•  Ensure there is no obstruction at all 
air intake and outlet vents.
•  After the start of operation for 15 
minutes, it is normal if the 
temperature differences between 
air intake and outlet vents at indoor 
unit is:-
Operation
Temperature
Cooling
   8°C
Heating
   14°C
•  Operate the unit for 2~3 hours using 
ion operation to dry the internal parts.
•  Turn off the power supply.
•  Remove the remote control batteries.
Switch off  the power supply 
Switch off  the power supply 
before cleaning
before cleaning
  Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling or heating capacity, unpleasant smells and higher 
energy consumption.
  The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an 
authorized dealer to perform seasonal inspections in addition to regular cleaning.
  This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner 
from being damaged by abnormally strong lightning activity, you may switch off the power supply.
Hints
■ Washing Instructions
•  Do not use benzene, thinner or 
scouring powder.
•  Use soaps or neutral household 
detergent (
pH7) only.
•  Do not use water with temperature 
higher than 40°C.
■ Pre-season Inspection
■ Preparation for extended 
Non-operation
•  It is recommended to clean the 
ionizer every 6 months.
IONIZER
QUIET POWERFUL ION
TIMER
POWER
Raise and pull to remove. 
Wash and dry.
FRONT PANEL
FRONT PANEL
Wipe gently.
IN
DOOR UNIT
INDOOR UNIT
Vacuum, wash and dry.
AIR FILTER
AIR FILTER
SUPERSONIC AIR 
SUPERSONIC AIR 
PURIFYING 
DEVICE
PURIFYING DEVICE
Clean with cotton 
bud.
IONIZER
IONIZER
Remove
Remove
Vacuum the super 
alleru-buster fi lter.
Vacuum, wash and 
dry the frame.
Remove
49
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
10 Installation Instructions
Required tools for Installation Works
1.
Philips screw driver
5.
Spanner
9.
Gas leak detector
13. Multimeter
2.
Level gauge
6.
Pipe cutter
10. Measuring tape
14. Torque wrench
18 N.m (1.8 kgf.m)
42 N.m (4.2 kgf.m)
55 N.m (5.5 kgf.m)
3.
Electric drill, hole core drill
(ø70 mm)
7.
Reamer
11. Thermometer
15. Vacuum pump
4.
Hexagonal wrench (4 mm)
8.
Knife
12. Megameter
16. Gauge manifold
10.1. Safety Precautions
  • Read the following “SAFETY PRECAUTIONS” carefully before installation.
  • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
for the model to be installed.
  • The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
  • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
2.
Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3.
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
electrical shock.
4.
Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6.
Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical shock.
8.
When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into
refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion
and injury.
9.
When connecting the piping, do not allow air or any substances other than the specified refrigerant (R410A) to enter the
refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and
possibly result in explosion and injury.
10.
  • When connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause
abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only
R410A materials.
  • Thickness of copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8
mm.
  • It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock.
50
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
1. Selection of the installation location.
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
 1. 
Power supply connection to the receptacle using a power plug.
Use an approved 15A/16A power plug with earth pin for the connection to the socket.
 2. 
Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
51
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
Attached accessories
Applicable piping kit
CZ-3F5, 7BP (E9DK)
CZ-4F5, 7, 10BP (E12DK)
SELECT THE BEST LOCATION
INDOOR UNIT
  • There should not be any heat source or steam near the
unit.
  • There should not be any obstacles blocking the air
circulation.
  • A place where air circulation in the room is good.
  • A place where drainage can be easily done.
  • A place where noise prevention is taken into
consideration.
  • Do not install the unit near the door way.
  • Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
  • Recommended installation height for indoor unit shall be
at least 2.3 m.
OUTDOOR UNIT
  • If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
  • There should not be any animal or plant which could be
affected by hot air discharged.
  • Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
  • Do not place any obstacles which may cause a short
circuit of the discharged air.
  • If piping length is over the rated length, additional
refrigerant should be added as shown in the table.
Indoor/Outdoor Unit Installation Diagram
  • This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
52
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD