15.5.12. H32 (Outdoor Heat Exchanger Temperature Sensor 2 Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor heat exchanger temperature
sensor are used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
70
15.5.13. H33 (Unspecified Voltage between Indoor and Outdoor)
Malfunction Decision Conditions
• The supply power is detected for its requirement by the indoor/outdoor transmission.
Malfunction Caused
• Wrong models interconnected.
• Wrong indoor unit and outdoor unit PCBs used.
• Indoor unit or outdoor unit PCB defective.
• Wrong indoor unit and outdoor unit PCBs used.
• Indoor unit or outdoor unit PCB defective.
Troubleshooting
71
15.5.14. H34 (Outdoor Heat Sink Temperature Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor heat sink temperature sensor are
used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
72
15.5.15. H36 (Outdoor Gas Pipe Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor gas pipe temperature sensor are
used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting