DOWNLOAD Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual ↓ Size: 8.57 MB | Pages: 112 in PDF or view online for FREE

Model
CS-E24JKDS CU-E24JKD CS-E28JKDS CU-E28JKD CS-XE24JKDS CU-XE24JKD
Pages
112
Size
8.57 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e24jkds-cu-e24jkd-cs-e28jkds-cu-e28jkd-cs-xe24j.pdf
Date

Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual ▷ View online

9
 MODEL
INDOOR
CS-E28JKDS
OUTDOOR
CU-E28JKD
I
N
D
O
O
R
F
A
N
Type
Cross-Flow Fan
Material
ASG30K1
Motor Type
Transistor (8-poles)
Input Power
W
85.1
Output Power
W
40
Speed
QLo
Cool
rpm
950
Heat
rpm
1040
Lo
Cool
rpm
1050
Heat
rpm
1140
Me
Cool
rpm
1260
Heat
rpm
1330
Hi
Cool
rpm
1470
Heat
rpm
1520
Shi
Cool
rpm
1520
Heat
rpm
1570
O
U
T
D
O
O
R
F
A
N
Type
Propeller Fan
Material
PP
Motor Type
Induction (6-poles)
Input Power
W
178.02
Output Power
W
80
Speed
Hi
Cool
rpm
710
Heat
rpm
680
Moisture Removal
L/h (Pt/h)
4.5 (9.5)
Indoor Airflow
QLo
Cool
m
3
/min (ft
3
/min)
11.90 (420)
Heat
m
3
/min (ft
3
/min)
13.20 (466)
Lo
Cool
m
3
/min (ft
3
/min)
13.30 (470)
Heat
m
3
/min (ft
3
/min)
14.60 (516)
Me
Cool
m
3
/min (ft
3
/min)
16.30 (576)
Heat
m
3
/min (ft
3
/min)
17.30 (611)
Hi
Cool
m
3
/min (ft
3
/min)
19.30 (680)
Heat
m
3
/min (ft
3
/min)
20.10 (710)
Shi
Cool
m
3
/min (ft
3
/min)
20.10 (710)
Heat
m
3
/min (ft
3
/min)
20.60 (727)
Outdoor Airflow
Hi
Cool
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Heat
m
3
/min (ft
3
/min)
52.4 (1850)
54.5 (1925)
Refrigeration Cycle
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FV50S (800)
Refrigerant Type
g (oz)
R410A, 1.80k (63.5)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 795 (31-5/16)
Width (I/D / O/D)
mm (inch)
1070 (42-5/32) / 875 (34-15/32)
Depth (I/D / O/D)
mm (inch)
235 (9-9/32) / 320 (12-5/8)
Weight
Net (I/D / O/D)
kg (lb)
12 (26) / 66 (132)
P
I
P
I
N
G
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Length for Additional Gas
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16
Length
mm
650
10
1. Cooling capacities are based on indoor temperature of 27
qC Dry Bulb (80.6qF Dry Bulb), 19.0qC Wet Bulb (66.2qF Wet Bulb)
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24qC Wet Bulb (75.2qF Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
qC Dry Bulb (68qF Dry Bulb) and outdoor air temperature of 7qC Dry
Bulb (44.6
qF Dry Bulb), 6qC Wet Bulb (42.8qF Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
qC, outdoor 2/1qC.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
qC, outdoor
-7/-8
qC.
5. Specifications are subjected to change without prior notice for further improvement.
 MODEL
INDOOR
CS-E28JKDS
OUTDOOR
CU-E28JKD
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row
u Stage u FPI
u 15 u 21
Size (W 
u H u L)
mm
810 
u 315 u 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row
u Stage u FPI
u 30 u 19
Size (W 
u H u L)
mm
38.1
u 762 u 895
                     865
Air Filter
Material
Polypropylene
Type
One-Touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6
11
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- Quick Cooling
- More precise temperature control
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
- Patrol sensor color changes to indicate the dirt level in the air
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
- CS/CU-E24/28JK, long piping up to 30 meter
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
- Blue coated condenser for high resistance to corrossion
• Operation Improvement
Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
• Serviceability Improvement
Breakdown Self Diagnosis function
12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 112
Display

Click on the first or last page to see other CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD service manuals if exist.