DOWNLOAD Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual ↓ Size: 8.57 MB | Pages: 112 in PDF or view online for FREE

Model
CS-E24JKDS CU-E24JKD CS-E28JKDS CU-E28JKD CS-XE24JKDS CU-XE24JKD
Pages
112
Size
8.57 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e24jkds-cu-e24jkd-cs-e28jkds-cu-e28jkd-cs-xe24j.pdf
Date

Panasonic CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD Service Manual ▷ View online

25
10.1.5.
High Voltage Power Supply Printed Circuit Board
26
10.2. Outdoor Unit
10.2.1.
Main Printed Circuit Board
27
10.2.2.
Power Printed Circuit Board
28
11 Installation Instruction
11.1. Select the Best Location
11.1.1.
Indoor Unit
• Do not install the unit in excessive oil fume area such as
kitchen, workshop and etc.
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
11.1.2.
Outdoor Unit
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the [piping length for additional gas],
additional refrigerant should be added as shown in the table.
Example: For E9***
If the unit is installed at 10 m distance, the quantity of additional
refrigerant should be 38 g .... (10-7.5) m x 15 g/m = 38 g.
11.1.3.
Indoor/Outdoor Unit Installation
Diagram
Model
Horse
Power
(HP)
Piping 
size
Std.
Length
(m)
Max.
Ele-
vation
(m)
Min.
Piping
Length
(m)
Max.
Piping
Length
(m)
Addi-
tional
Refri-
gerant
(g/m)
Piping
Length
for 
add. 
gas
(m)
Gas
Li-
quid
E7***,
XE7***
3/4 ~
1.75HP
3/8”
1/4”
5
15
3
15
20
7.5
E9***,
XE9***
15
3
15
20
7.5
E12***,
XE12***
15
3
15
20
7.5
E15***,
XE15***
1/2”
15
3
15
20
7.5
E18***,
XE18***
2.0 ~
3.0HP
15
3
20
20
10
E21***,
XE21***
15
3
20
20
10
E24***,
XE24***
5/8”
20
3
30
30
10
E28***
20
3
30
30
10
Page of 112
Display

Click on the first or last page to see other CS-E24JKDS / CU-E24JKD / CS-E28JKDS / CU-E28JKD / CS-XE24JKDS / CU-XE24JKD service manuals if exist.