DOWNLOAD Panasonic CS-E24CKE / CU-E24CKE Service Manual ↓ Size: 13.08 MB | Pages: 93 in PDF or view online for FREE

Model
CS-E24CKE CU-E24CKE
Pages
93
Size
13.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-e24cke-cu-e24cke.pdf
Date

Panasonic CS-E24CKE / CU-E24CKE Service Manual ▷ View online

 1. The Electronic Controller, a Signal Receiver and an
Indicator (Fig. 3) can be seen by the below steps:
  • Open the Intake Grille and remove the screw at the front
of the Front Grille. (Fig. 1).
  • Remove the 3 caps and 3 screws at the bottom of the
Front Grille. (Fig. 1)
  • Remove the Front Grille by releasing the 3 hooks at the
top of the Front Grille. (Fig. 1)
  • Unhook the tabs at the Control Board to remove the
Control Board Cover. (Fig. 2)
 2. To remove the Main Electronic Controller:
  • Release the 2 Particular Piece. (Fig. 3)
  • Release the CN-REC/DISP connectors. (Fig. 4)
  • Release the CN-TH connector. (Fig. 4)
  • Release the CN-MAIN connector. (Fig. 4)
  • Release the CN-STM1 connector. (Fig. 4)
  • Release the CN-STM2 connector. (Fig. 4)
  • Release the hooks that hold the Electronic Controller.
(Fig. 3)
 3. To remove the Power Electronic Controller:
  • Release the CN-001 connector. (Fig. 4)
  • Release the CN-002 connector. (Fig. 4)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
12.4. Indoor Electronic Controllers Removal Procedures
73
CS-E24CKE CU-E24CKE
 1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
 a. Release the Earth Wire screw. (Fig. 5)
 b. Release the Intake Air Sensor. (Fig. 5)
 c. 
Release the Piping Sensor. (Fig. 5)
 d. Release the CN-REC connectors. (Fig. 5)
 e. Release the CN-STM1. (Fig. 5)
 f. 
Release the CN-STM2. (Fig. 5)
 g. Release connectors generator Ionizer. (Fig. 5)
 2. Pull out the Drain Hose from outlet to remove the Discharge
Grille. (Fig. 6)
 3. Removing the right and left screws. (Fig. 7)
 4. By pressing down the hook at the left and pushing up the
hook at the right, you will be able to remove the Control
Board. (Fig. 7)
 5. Remove the screw at the Cross Flow Fan. (Fig. 8)
Fig. 5
Fig. 6
Fig. 7
Fig. 8
12.5. Cross Flow Fan and Indoor Fan Motor Removal Procedures
74
CS-E24CKE CU-E24CKE
 6. Remove the Bearing. (Fig. 9)
 7. Remove the screws at the left of the Evaporator. (Fig. 9)
 8. Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 10).
REMINDER - To reinstall the Fan Motor, put it back in
place, adjust the position of the Fan Motor’s leadwire
appropriately as shown in the Fig. 8 before installing the
Cross Flow Fan.
Fig. 9
Fig. 10
75
CS-E24CKE CU-E24CKE
 1. Remove the top panel and front panel
Fig. 16
 2. Remove the Outdoor Electronic Controller
Fig. 18
Caution! When handling electronic controller, be careful of
electrostatic discharge.
  • Be save to return the wiring to its original position
  • There are many high voltage components within the heat
sink cover so never touch the interior during operation.
Wait at least two minutes after power has been turned off.
Fig. 19
12.6. Outdoor Electronic Controller Removal Procedure
76
CS-E24CKE CU-E24CKE
Page of 93
Display