DOWNLOAD Panasonic CS-E24CKE / CU-E24CKE Service Manual ↓ Size: 13.08 MB | Pages: 93 in PDF or view online for FREE

Model
CS-E24CKE CU-E24CKE
Pages
93
Size
13.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-e24cke-cu-e24cke.pdf
Date

Panasonic CS-E24CKE / CU-E24CKE Service Manual ▷ View online

2.
Troubleshooting Air Conditioner
Refrigeration cycle system
In order to diagnose malfunctions, make sure that there are
no electrical problems before inspecting the refrigeration
cycle.
Such
problems
include
insufficient
insulation,
problem
with
the
power
source,
malfunction
of
a
compressor and a fan.
The normal outlet air temperature and pressure of the
refrigeration cycle depends on various conditions, the
standard values for them are shown in the table to the right.
69
CS-E24CKE CU-E24CKE
1. Relationship between the condition of the air conditioner and pressure and electric current
Cooling Mode
Heating Mode
Condition of the air
conditoner
Low Pressure
High Pressure
Electric current
during operation
Low Pressure
High Pressure
Electric current
during operation
Insufficient refrigerant
(gas leakage)
Clogged capillary tube
or Strainer
Short circuit in the
indoor unit
Heat radiation
deficiency of the
outdoor unit
Inefficient compression
  • Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.
12.2. Breakdown Self Diagnosis Function
Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
  • Press “CHECK” button at remote control continuously for more than five seconds to turn on the diagnosis mode, “H11” will be
displayed at remote control.
  • By pressing the TMER “ ” button once, next error code will be displayed; press “V” button once, previous error code will be
displayed.
  • If error code displayed matches the error code saved in unit memory (abnormality detected), four “beep” sounds will be heard
and Power LED will light on. Otherwise, one “beep” sound is heard.
If “CHECK” button is press again during Cooling operation using test run operation mode for 30 seconds, the diagnosis mode will
turn off.
70
CS-E24CKE CU-E24CKE
Error Codes Table
Diagnosis
display
Abnormality / Protection control
Abnormality
Judgement
Emergency
operation
Primary location to verify
H11
Indoor / outdoor abnormal
communication
> 1 min after starting
operation
Indoor fan operation
only
  • Internal / external cable connections
  • Indoor / Outdoor PCB
H14
Indoor intake air temperature sensor
abnormality
Continue for 5 sec.
  • Intake air temperature sensor
(defective or disconnected)
H15
Outdoor compressor temperature sensor
abnormality
Continue for 5 sec.
  • Compressor temperature sensor
(defective or disconnected)
H16
Outdoor Current Transformer open
circuit
  • Outdoor PCB
  • IPM (Power transistor) module
H19
Indoor fan motor merchanism lock
  • Indoor PCB
  • Fan motor
H23
Indoor heat exchanger temperature
sensor abnormality
Continue for 5 sec.
O
(Cooling only)
  • Heat exchanger temperature sensor
(defective or disconnected)
H26
Ion abnormality
  • Indoor PCB
  • Ionizer
H27
Outdoor air temperature sensor
abnormality
Continue for 5 sec.
O
  • Outdoor temperature sensor
(defective or disconnected)
H28
Outdoor heat exchanger temperature
sensor abnormality
Continue for 5 sec.
O
  • Outdoor heat exchanger
temperature sensor (defective or
disconnected)
H33
Indoor/Outdoor wrong connection
  • Indoor/Outdoor supply voltage
H97
Outdoor Fan Motor lock abnormality
  • Outdoor PCB
  • Outdoor Fan Motor
H98
Indoor high pressure protection
  • Air filter dirty
  • Air circulation short circuit
H99
Indoor heat exchanger anti-freezing
protection
  • Insufficient refrigerant
  • Air filter dirty
F11
Cooling / Heating cycle changeover
abnormality
4 times occurance
within 30 minutes
  • 4-way valve
  • V-coil
F90
PFC control
4 times occurance
within 10 minutes
  • Voltage at PFC
F91
Refrigeration cycle abnormality
7 times occurance
continuously
  • No refrigerant
(3-way valve is closed)
F93
Outdoor compressor abnormal revolution
4 times occurance
within 20 minutes
  • Outdoor compressor
F95
Cool high pressure protection
4 times occurance
within 20 minutes
  • Outdoor refrigerant circuit
F96
IPM (power transistor) overheating
protection
  • Excess refrigerant
  • Improper heat radiation
  • IPM (Power transistor)
F97
Outdoor compressor overheating
protection
4 times occurance
within 20 minutes
  • Insufficient refrigerant
  • Compressor
F98
Total running current protection
3 times occurance
within 20 minutes
  • Excess refrigerant
  • Improper heat radiation
F99
Outdoor Direct Current (DC) peak
detection
7 times occurance
continuously
  • Outdoor PCB
  • IPM (Power transistor)
  • Compressor
Note:
“O” - Frequency measured and fan speed fixed.
The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard
following by pressing the “RESET” button at Remote Control.
Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error
Codes Table) by using Remote Control or Auto Switch at indoor unit. However, the Remote Control signal receiving sound is
changed from one “beep” to four “beep” sounds.
71
CS-E24CKE CU-E24CKE
  • Remote Control Reset
When the batteries are inserted for the first time, or the
batteries are replaced, all the indications will blink and the
remote control might not work.
If this happen, remove the cover of the remote control and
push the reset point once to clear the memory data.
  • Changing the wireless remote control transmission
code
When there are more than one indoor units installed in the
same room, it is possible to set different remote control
receiving signal by modifying the jumpers inside Remote
Control.
12.3. Remote Control
72
CS-E24CKE CU-E24CKE
Page of 93
Display

Click on the first or last page to see other CS-E24CKE / CU-E24CKE service manuals if exist.