Panasonic CS-E21JB4EA / CU-E21HBEA Service Manual ▷ View online
57
15.5.10. H28 (Outdoor Pipe Temperature Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor are used
to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
58
15.5.11. H30 (Compressor Discharge Temperature Sensor Abnormality)
Malfunction Decision Conditions
• During startup and operation of cooling and heating, the temperatures detected by the outdoor discharge pipe temperature
sensor are used to determine sensor errors.
Malfunction Caused
• Faulty connector connection.
• Faulty sensor.
• Faulty PCB.
• Faulty sensor.
• Faulty PCB.
Troubleshooting
59
15.5.12. H33 (Unspecified Voltage between Indoor and Outdoor)
Malfunction Decision Conditions
• The supply power is detected for its requirement by the indoor/outdoor transmission.
Malfunction Caused
• Wrong models interconnected.
• Wrong indoor unit and outdoor unit PCBs used.
• Indoor unit or outdoor unit PCB defective.
• Wrong indoor unit and outdoor unit PCBs used.
• Indoor unit or outdoor unit PCB defective.
Troubleshooting
60
15.5.13. H97 (Outdoor Fan Motor – DC Motor Mechanism Locked)
Malfunction Decision Conditions
• The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor.
Malfunction Caused
• Operation stops due to short circuit inside the fan motor winding.
• Operation stops due to breaking of wire inside the fan motor.
• Operation stops due to breaking of fan motor lead wires.
• Operation stops due to Hall IC malfunction.
• Operation error due to faulty outdoor unit PCB.
• Operation stops due to breaking of wire inside the fan motor.
• Operation stops due to breaking of fan motor lead wires.
• Operation stops due to Hall IC malfunction.
• Operation error due to faulty outdoor unit PCB.
Troubleshooting
Click on the first or last page to see other CS-E21JB4EA / CU-E21HBEA service manuals if exist.