Panasonic CS-E21HKDS / CS-E24HKDS / CU-E21HKD / CU-E24HKD Service Manual ▷ View online
69
Heating Characteristic at Different Outdoor Air Temperature
Condition
Indoor room temperature : 20/-
Indoor room temperature : 20/-
qC
Remote control setting : HI FAN, HEAT 30
qC
Compressor frequency : Rated heating
Voltage : 220/230 V
Voltage : 220/230 V
70
Cooling Characteristic at Different Piping Length
Condition
Indoor room temperature : 27/19
Indoor room temperature : 27/19
qC, 35/-qC
Remote control setting : HI FAN, COOL 16
qC
Compressor frequency : Rated cooling
Voltage : 220/230 V
Voltage : 220/230 V
71
Heating Characteristic at Different Piping Length
Condition
Indoor room temperature: 20/-
Indoor room temperature: 20/-
qC, 7/6qC
Remote control setting: HI FAN, HEAT 30
qC
Compressor frequency: Rated heating
Voltage: 220/230 V
Voltage: 220/230 V
72
17.2. Sensible Capacity Chart
CS-E21HKDS CU-E21HKD
CS-E24HKDS CU-E24HKD
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.25
4.74
2.02
5.84
4.54
2.18
5.43
4.37
2.33
4.94
4.15
2.51
19.0
qC
6.30
2.21
19.5
qC
6.86
4.96
2.06
6.41
4.77
2.22
5.97
4.59
2.37
5.42
4.37
2.56
22.0
qC
7.48
5.14
2.10
6.99
4.95
2.26
6.50
4.77
2.42
5.91
4.55
2.61
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
qC
6.80
2.12
19.5
qC
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
qC
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)
Click on the first or last page to see other CS-E21HKDS / CS-E24HKDS / CU-E21HKD / CU-E24HKD service manuals if exist.