Panasonic CS-E18GKDW / CU-E18GKD / CS-E21GKDS / CU-E21GKD Service Manual ▷ View online
17
10 Printed Circuit Board
10.1. Indoor Unit
10.1.1.
Main Printed Circuit Board
18
10.1.2.
Power Printed Circuit Board
10.2. Indicator
19
10.3. Outdoor Unit
20
11 Installation Instruction
11.1. Select The Best Location
INDOOR UNIT
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over 10 m, additional refrigerant should be
added as shown in the table.
Example : For E18GK
If the unit is installed at a 15 m distance, the quantity of
additional refrigerant should be 100 g ...... (15 - 10) m x 20 g/m
If the unit is installed at a 15 m distance, the quantity of
additional refrigerant should be 100 g ...... (15 - 10) m x 20 g/m
= 100 g.
11.2. Indoor/Outdoor Unit
Installation Diagram
Model
Piping size
Rated
Length
(m)
Max
Elevation
(m)
Min.
Piping
Length
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Gas Liquid
E18GK 1/2”
1/4”
5
15
3
20
20
E21GK 1/2”
1/4”
5
15
3
20
20
Click on the first or last page to see other CS-E18GKDW / CU-E18GKD / CS-E21GKDS / CU-E21GKD service manuals if exist.