■ Operation Details
Auto, Heat, Cool, 
Dr y
Auto, Heat, Cool, Dr y
2
2
Select the 
desired 
operation.
3
3
Set the
temperature.
(16°C~30°C)
Start the 
operation.
1
1
HOW TO OPERATE
● Supersonic air purifying device (super alleru-buster) operates 
automatically while the air conditioner is switched on.
● Powerful, Quiet and Ion operations could be activated in all 
operation modes.
● Press 
 button again to stop the operation.
AUTO - Automatic Operation
•  Enables you to enjoy the cooling 
effect at your preferred setting 
temperature.
COOL - Cooling Operation
•  Enables you to set the desired 
temperature at low fan speed which 
provides you with the dehumidifying 
surroundings.
DRY - Soft Dry Operation
•  The unit will automatically select 
the operation mode according 
to the setting, outdoor and room 
temperature. During operation mode 
selection, power indicator blinks. 
For every 30 minutes, the operation 
mode is reselected.
•  Enables you to enjoy the warming 
effect at your preferred setting 
temperature.
•  For cold air prevention, air might 
not blow out immediately and 
power indicator blinks when 
operation starts.
•  Also operates in defrost mode 
(maximum 10 minutes) where by 
the power indicator blinks. The 
melted frost is drained at outdoor 
unit and indoor fan is stopped.
HEAT - Heating Operation
AUTO
COOL
HEAT
DRY
Troubleshooting
  The room has a peculiar odour.
  This may be a damp smell emitted by the wall, carpet, furniture or 
clothing in the room.
  Air conditioner does not cool or heat effi ciently.
  Ensure the temperature has been set correctly.
  Ensure windows and doors have been closed properly.
  Ensure fi lters are cleaned or replaced when necessary.
  Ensure inlet and outlet vents of the units have not been obstructed.
  To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
Hint
49
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
Adjust the vertical 
or horizontal airfl ow
direction louver.
3
1
■ Operations Details
•  To provide fresh air effect by 
producing negative ions.
•  Ion operation could be activated 
independently.
•  Press 
 button to stop the 
operation.
•  To achieve setting temperature 
quickly.
ION
POWERFUL
Enables 
powerful 
operation.
Enables ion 
operation.
ION
ION
Powerful, 
Powerful, Quiet, 
Quiet, Ion, Fan Speed, 
Ion, Fan Speed, 
Air Swing
Air Swing
POWERFUL
POWERFUL
Select fan speed.
FAN SPEE
D
FAN SPEED
AIR SWING
AIR SWING
•  To provide a quiet environment.
QUIET
● Powerful and Quiet operations could not be activated at the 
same time.
● Powerful, Quiet and Ion operations could be cancelled by 
pressing the respective button again.
Troubleshooting
  ION indicator on the indoor unit is blinking.
  Press ION button twice. If the indicator is still blinking, please consult 
the dealer.
  Indoor fan stops occasionally during Automatic Fan 
Speed setting.
  Indoor fan stops occasionally during heating operation.
  This is an advanced feature that helps to remove smell from the 
surrounding area during operation.
  To avoids unintended cooling effect.
HOW TO OPERATE
Hints
  If you wish to have the cool air blowing directly on you, set the airfl ow direction downward but not for an excessive length of time, 
as it may harm your health.
  Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating 
operation than the desired temperature.
•  To provide you with the various fan 
speed selections.
•  There are 5 levels of fan speed in 
addition to automatic fan speed.
•  Automatic fan speed:
  The speed of the indoor fan is 
automatically adjusted according to 
the operation.
FAN SPEED
•  To ventilate air in the room.
•  There are 5 selections in addition to 
automatic vertical air fl ow direction.
•  If automatic vertical airfl ow direction 
has been set, the louver swings up 
and down automatically.
•  To ventilate air in the room.
•  There are 5 selections in addition 
to automatic horizontal air fl ow 
direction.
•  If automatic horizontal airfl ow 
direction has been set, the louver 
swings left and right automatically.
•  Please do not adjust the vertical and 
horizontal airfl ow direction louver 
manually.
AIR SWING
Enables quiet 
operation.
QUIET
QUIET
50
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
HOW TO OPERATE
1
1
Select ON or 
OFF timer.
2
2
Set the 
desired time.
3
3
Confi rm the 
setting.
Timer
Timer
CANCEL
CANCEL
Cancel the 
selected timer.
■ Operation Details
•  Use the ON timer to turn on the air 
conditioner at the desired time. This 
will give you a cooling or warming 
environment, e.g. when you return 
from work or wake up.
•  When the ON timer is set, operation 
will start up to 35 minutes before the 
actual set time.
•  Use the OFF timer to stop the air 
conditioner operation at the desired 
time. This can save electricity while 
you are going out or sleeping.
•  The set timer will repeat daily once 
it is set.
•  If there is a power failure, you can 
press SET button to restore the 
previous setting once the power is 
resumed.
•  If the timer is cancelled, you can 
restore the previous setting by 
pressing SET button.
TIMER
  Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.
  For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.
Hint
Troubleshooting
  TIMER indicator always on.
  Timer is activated and the setting will repeat itself daily.
  POWER indicator is blinking 35 minutes before ON 
timer is activated.
  The unit is determining the operation mode by sensing the room 
temperature. This happens when it has been set to AUTO operation 
mode.
● Ensure the clock on the remote control has been set 
correctly.
● You could use the ON and OFF timers at the same time.
● To cancel either the ON or OFF timer, press 
 or 
, then 
press 
.
CHECK
•  When there is error, the unit stops 
its operation and timer indicator 
blinks.
1. Press for 5 seconds.
2. Browse for respective error code, 
where “beep” sounds are heard.
3. Turn off the power supply and call 
authorized distributor.
Note:
Press the ‘Reset’ button to quit 
checking.
Unit might operate with limited function 
depending on error found.
(Operation starts, 4 “beep” sounds are 
heard)
51
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
CARE & CLEANING
•  Wipe the unit gently with a soft, dry 
cloth.
•  It is recommended to clean the air 
fi lters once every 2 weeks.
•  Purchase the replacement fi lter if it 
is damaged.
  Part no.: CWD001144
INDOOR UNIT
AIR FILTER
•  It is recommended to clean the fi lter 
every 6 months.
•  Replace the fi lter every 3 years or 
purchase the replacement fi lter if it 
is damaged. 
  Part no.: CZ-SA13P
SUPER ALLERU-BUSTER
•  This inspection is recommended 
before operating the air conditioner 
at every season.
•  Check if the remote control batteries 
needed to be replaced.
•  Ensure there is no obstruction at all 
air intake and outlet vents.
•  After the start of operation for 15 
minutes, it is normal if the 
temperature differences between 
air intake and outlet vents at indoor 
unit is:-
Operation
Temperature
Cooling
   8°C
Heating
   14°C
•  Operate the unit for 2~3 hours using 
ion operation to dry the internal parts.
•  Turn off the power supply.
•  Remove the remote control batteries.
Switch off  the power supply 
Switch off  the power supply 
before cleaning
before cleaning
■ Washing Instructions
•  Do not use benzene, thinner or 
scouring powder.
•  Use soaps or neutral household 
detergent (
pH7) only.
•  Do not use water with temperature 
higher than 40°C.
■ Pre-season Inspection
■ Preparation for extended 
Non-operation
•  It is recommended to clean the 
ionizer every 6 months.
IONIZER
QUIET POWERFUL ION
TIMER
POWER
Raise and pull to remove. 
Wash and dry.
FRONT PANEL
FRONT PANEL
Wipe gently.
IN
DOOR UNIT
INDOOR UNIT
Vacuum, wash and dry.
AIR FILTER
AIR FILTER
SUPERSONIC AIR 
SUPERSONIC AIR 
PURIFYING 
DEVICE
PURIFYING DEVICE
Clean with cotton 
bud.
IONIZER
IONIZER
Remove
Remove
Vacuum the super 
alleru-buster fi lter.
Vacuum, wash and 
dry the frame.
Remove
  Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling or heating capacity, unpleasant smells and higher 
energy consumption.
  The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an 
authorized dealer to perform seasonal inspections in addition to regular cleaning.
  This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner 
from being damaged by abnormally strong lightning activity, you may switch off the power supply.
Hints
52
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD