 3. Deice condition:
OD air temp. t
0°C.
OD heat exchanger temp.
0°C for 14 min.
OD heat exchanger temp.
-8°C for 10 min.
 4. Auto clean deice time chart
Similar to deice operation 2 except for frequency values.
 a. Detection methods
Outdoor heat exchanger temp. sensor, timer, indoor air temp. sensor.
 b. Deice operation control time chart.
45
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
Outdoor heat exchanger pipe temperature
a
15°C
b
18°C
c
25°C
Notes
 1. During deice operation, the relationship between outdoor pipe temperature and time T1 is such proceed to next
operation.
 2. The deice will be performed only after 1 hour from when the operation has started.
 3. When Comp. OFF by the sequence No. 1, 6, 7 compressor can restart back without 3 minutes waits (immediate restart).
46
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
9 Operating Instructions
9.1. CS-E15DKDW
The appliance is not intended for use by young children or infi rm 
person without supervision. Young children should be supervised to 
ensure that they do not play with the appliance.
Thank you for purchasing Panasonic Air Conditioner
SAFETY PRECAUTIONS
■ Definition
Safety Regulation
Operation Condition (
O
C)
Use this air conditioner under the following temperature 
range.
DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature
Indoor
Outdoor
DBT
WBT
DBT
WBT
Maximum Temperature (COOL)
32
23
43
26
Maximum Temperature (HEAT)
30
24
18
Minimum Temperature (COOL)
16
11
-5
Minimum Temperature (HEAT)
16
-5
-6
This sign warns of death 
or serious injury.
To prevent personal injury, 
injury to others and property 
damage, the following 
instructions must be 
followed.
Incorrect operation due to 
failure to follow instructions 
will cause harm or damage, 
the seriousness of which is 
classifi ed as below:
This symbol denotes 
an action that is 
PROHIBITED.
Caution
•  This air conditioner must be earthed. Improper grounding will cause electric shock.
•  Ensure that the drainage piping is connected properly. Otherwise, water will leak.
•  Current leakage protection equipment must be installed. Otherwise, electric shock or fi re may 
occur.
•  Do not install the unit in a potentially explosive atmosphere.
Warning
Do not install, remove and reinstall the unit by yourself.
•  Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or 
specialist for the installation work.
These symbols denote 
actions that are 
COMPULSORY.
Warning
This sign warns of injury 
or damage to property.
Caution
The instructions to be 
followed are classifi ed by 
the following symbols:
Installation Precautions
Installation Precautions
Operation
Operation Precautions
 Precautions
•  Use specifi ed supply cord.
•  If the supply cord is damaged or needed 
to be replaced, it must be replaced by 
the manufacturer or its service agent or 
a similarly qualifi ed person in order to 
avoid a hazard.
•  Remove the batteries if the unit is not 
going to be use for a long period of time.
•   New batteries of the same type must be 
inserted following the polarity stated to 
prevent malfunction of the remote control.
•  In case of emergency or abnormal 
condition (burnt, smell, etc) occurs, turn 
off the power supply.
•  Do not share power outlet.
•  Do not modify power cord.
•  Do not use an extension cord.
•  Do not operate with wet hands.
•   Do not insert fi nger or other objects into the 
indoor or outdoor unit.
•  Do not attempt to repair the unit by 
yourself.
•  Do not use rechargeable (Ni-Cd) batteries.
•  Keep the remote control away from infants 
and small children to prevent them from 
accidentally swallowing the batteries.
Warning
•  Do not wash the unit with water, benzene, 
thinner or scouring powder.
•   Do not use for other purposes such as 
preservation of food.
•  Do not use any combustible equipment at 
airfl ow direction.
•  Do not sit or place anything on the indoor 
or outdoor unit.
•  Do not expose directly to cold air for a 
long period.
•  Ventilate the room regularly.
•  Pay attention as to whether the 
installation rack is damaged after long 
period of usage.
•  Switch off the power supply before 
cleaning or servicing.
•  Turn off the power supply if the unit is not 
used for a long period of time.
Caution
47
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
QUIET POWERFUL ION
TIMER
POWER
QUIET POWERFUL ION
SUPER
ALLERU-BUSTER
TIMER
POWER
Air intake
Airflow direction louver
Ionizer
Air filter
Front panel
I
Indoor Unit
ndoor Unit
Indicator
Supersonic air 
purifying device
Auto OFF/ON 
button
Receiver
Discharged air
Do not touch 
during operation
Note: 
The illustrations in this manual are for explanation purposes only and may differ from the 
actual unit. It is subjected to change without notice for future improvement.
PRODUCT OVERVIEW
Outdoor
Outdoor Unit
 Unit
Air inlet 
(rear)
Air outlet
■ About
Remote Control Preparation
•  Make sure it is not obstructed.
•  Maximum distances: 10m.
•  Certain fluorescent lights may 
interfere with signal transmission. 
Consult your dealer.
Remote Control Signal
•  To operate the unit if the 
remote control is misplaced or 
malfunctioning.
Action
Operation 
mode
Press once
 Automatic 
Operation
Press until “beep” 
sound and release.
 Cooling 
Operation
Press until “beep” 
sound and release.
Press again until 
“beep-beep” sound 
and release.
 Heating 
Operation
•  To OFF, press again the Auto OFF/
ON button.
Auto OFF/ON Button
1. Pull out
2. Insert 
batteries
  (AAA or 
R03)
5. Press again to confi rm
•  Timer operation will be based on 
current time set.
•  The batteries can be used for 
approximately 1 year.
•  The batteries must be 
recycled or disposed of 
properly.
3. Press CLOCK button
4. Set 
current 
time
Troubleshooting
  Operation delayed for few minutes after restart.
  This is a normal self protection control.
  Sound like water fl owing during operation.
  Caused by refrigerant fl ow inside.
  Mist emerges from indoor unit.
  Condensation effect due to cooling process.
  Noisy during operations.
  Installation work could be slanted or front panel didn’t close properly.
  Remote control/display does not work.
  Check whether batteries are correctly inserted or need replacement.
  The unit cannot operate.
  Check either circuit breaker is tripped or timer is used correctly.
  Outdoor unit emits water/steam.
  Condensation or evaporation happens at piping surface.
Air inlet 
(side)
LCD display
Off/On
Fan speed selection
Memory reset
Clock setting
Temperature setting
Powerful operation
Operation mode
Quiet operation
Timer setting
Ion operation
Airflow direction 
adjustment
Remote Control
Remote Control
Transmitter
Check
48
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
Page of 122
Display

Click on the first or last page to see other CS-E15DKDW / CU-E15DKD / CS-E18DKDW / CU-E18DKD / CS-E21DKDS / CU-E21DKD service manuals if exist.