DOWNLOAD Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual ↓ Size: 5.8 MB | Pages: 84 in PDF or view online for FREE

Model
CS-CE9JKE CU-CE9JKE CS-CE12JKE CU-CE12JKE
Pages
84
Size
5.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-ce9jke-cu-ce9jke-cs-ce12jke-cu-ce12jke.pdf
Date

Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual ▷ View online

9
Out
d
oor F
a
n
Type
Propeller Fan
Material
PP
Motor Type
DC Type (8-poles)
Input Power
W
Output Power
W
40
Speed
Hi
Cool
rpm
840
Heat
rpm
820
Moisture Removal
L/h (Pt/h)
2.0 (4.2)
Indoor Airflow
Lo
Cool/Fan m
3
/min (ft
3
/min)
6.3 (220)
Heat
m
3
/min (ft
3
/min)
9.4 (332)
Me
Cool/Fan m
3
/min (ft
3
/min)
8.5 (300)
Heat
m
3
/min (ft
3
/min)
11.0 (389)
Hi
Cool/Fan m
3
/min (ft
3
/min)
12.5 (440)
Heat
m
3
/min (ft
3
/min)
12.8 (450)
Outdoor Airflow
Hi
Cool
m
3
/min (ft
3
/min)
31.0 (1090)
Heat
m
3
/min (ft
3
/min)
30.2 (1070)
Refrigeration Cycle
Control Device
Check Valve & Capillary Tube
Refrigerant Oil
cm
3
RB68A or Freol Alpha 68M (400)
Refrigerant Type
g (oz)
R410A, 970 (34.2)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11-7/16) / 540 (21-9/32)
Width (I/D / O/D)
mm (inch)
870 (34-9/32) / 780 (30-23/32)
Depth (I/D / O/D)
mm (inch)
204 (8-1/16) / 289 (11-13/32)
Weight
Net (I/D / O/D)
kg (lb)
9 (20) / 35 (77)
Pipi
n
g
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.7 (1/2)
Standard Length
m (ft)
5 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height Different
m (ft)
5 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Length for Additional Gas
m (ft)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
16
Length
mm
650
Indoor Heat 
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 21
Size (W x H x L)
mm
610 x 315 x 25.4
Outdoor Heat 
Exchanger
Fin Material
Aluminium
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 24 x 17
Size (W x H x L)
mm
36.4 x 504 x 725
713
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
MODEL
INDOOR
CS-CE12JKE
OUTDOOR
CU-CE12JKE
10
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
°C, outdoor
-7/-8
°C
5. Specifications are subjected to change without prior notice for further improvement.
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-15
-6
MODEL
INDOOR
CS-CE12JKE
OUTDOOR
CU-CE12JKE
11
3 Features
• Inverter Technology
- Wider output power range
- Energy saving
- More precise temperature control
• Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
• Long Installation Piping
- Long piping up to 15 meters during single split connection only
• Easy to use remote control
• Quality Improvement
Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect Compressor
- Noise prevention during soft dry operation
• Operation Improvement
- 24-hour timer setting
• Serviceability Improvement
Breakdown Self Diagnosis function
12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
Page of 84
Display