Panasonic CS-C18JKD / CU-C18JKD / CS-C24JKD / CU-C24JKD Service Manual ▷ View online
5
2 Specifications
MODEL
INDOOR
CS-C18JKD
CS-C24JKD
OUTDOOR
CU-C18JKD
CU-C24JKD
Performance Test Condition
NEW JIS
NEW JIS
Power Supply
Phase, Hz
Single, 50
Single, 50
V
220
230
220
230
Cooling
Capacity
kW
5.30
5.30
7.03
7.03
BTU/h
18100
18100
24000
24000
kJ/h
—
—
—
—
Running Current
A
8.2
8.3
11.5
11.6
Input Power
W
1.72k
1.76k
2.35k
2.41k
EER
W/W
3.08
3.01
2.99
2.92
BTU/hW
10.52
10.28
10.21
9.96
Power Factor
%
95
92
93
90
Indoor Noise (H / L)
dB-A
42 - 42 / 37 - 37
46 - 46 / 40 - 40
Power Level dB
58 / 58
62 / 62
Outdoor Noise (H / L)
dB-A
53 / 54
53 / 54
Power Level dB
68 / 69
68 / 69
Max Current (A) / Max Input Power (W)
12.2 / 2.59k
15.1 / 3.22k
Starting Current (A)
40
65
Compressor
Type
Hermetic Motor
Hermetic Motor
Motor Type
Induction (2-poles)
Induction (2-poles)
Output Power
W
1.5k
2.2k
Indoor
Fan
Type
Cross-flow Fan
Cross-flow Fan
Material
ASG30K1
ASG30K1
Motor Type
DC Motor
DC Motor
Input Power
W
94.8 - 94.8
60
Output Power
W
40
40
Speed
Lo
rpm
1010 - 1010
1110 - 1110
Me
rpm
1120 - 1120
1230 - 1230
Hi
rpm
1240 - 1240
1350 - 1350
SHi
rpm
1390 - 1390
1500 - 1500
Out
door Fan
Type
Propeller Fan
Propeller Fan
Material
PP Resin
PP Resin
Motor Type
Induction (6-poles)
Induction (6-poles)
Input Power
W
86.5
133.5
Output Power
W
36
66
Speed
Lo
rpm
—
420 - 480
Me
rpm
—
—
Hi
rpm
830 - 840
770 - 800
SHi
rpm
—
—
Moisture Removal
L/h (Pt/h)
2.9 (6.1)
4.0 (8.5)
Indoor Airflow
Lo
m
3
/min (ft
3
/min)
13.4 (472) - 13.4 (472)
15.0 (528) - 15.0 (528)
Me
m
3
/min (ft
3
/min)
14.8 (523) - 14.8 (523)
16.2 (586) - 16.2 (586)
Hi
m
3
/min (ft
3
/min)
16.4 (579) - 16.4 (579)
18.2 (642) - 18.2 (642)
SHi
m
3
/min (ft
3
/min)
18.4 (649) - 18.4 (649)
20.2 (714) - 20.2 (714)
Outdoor Airflow
Hi
m
3
/min (ft
3
/min)
30.3 (1070) - 30.8 (1090)
45.5 (1610) - 46.5 (1640)
Refrigerant Cycle
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
ATMOS NM56 or SUNISO 4GDID
(450)
ATMOS M60 or SUNISO 4GDID (700)
Refrigerant Type
g (oz)
0.95k (33.5)
1.39k (49.1)
Dimension
Height (I/D / O/D)
mm (inch)
290 (11 - 7/16)
540 (21 - 9/32)
290 (11 - 7/16)
750 (29 - 17/32)
Width (I/D / O/D)
mm (inch)
1070 (42 - 5/32)
780 (30 - 23/32)
1070 (42 - 5/32)
875 (34 - 15/32)
Depth (I/D / O/D)
mm (inch)
235 (9 - 9/32)
289 (11 - 13/32)
235 (9 - 9/32)
345 (13 - 19/32)
6
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Specifications are subjected to change without prior notice for further improvement.
Weight
Net (I/D / O/D)
kg (lb)
12 (26)
37 (82)
12 (26)
56 (123)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
6.35 (1/4) / 15.88 (5/8)
Standard Length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length Range (min - max)
m (ft)
3 (9.8) ~ 25 (82.0)
3 (9.8) ~ 25 (82.0)
I/D & O/D Height Different
m (ft)
20 (65.6)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
30 (0.3)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
12
12
Length
mm
550
550
Indoor Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 21
2 x 15 x 21
Size (W x H x L)
mm
810 x 315 x 25.4
810 x 315 x 25.4
Outdoor Heat Exchanger
Fin Material
Aluminium (Blue Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 24 x 17
2 x 34 x 17
Size (W x H x L)
mm
25.4 x 504 x 693.4
713.4
25.4 x 714 x 831.2
811.2
Air Filter
Material
Polypropelene
Polypropelene
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
16
20
Thermostat
—
Mechanical
Protection Device
—
—
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor Operation Range
Maximum
32
23
32
23
Minimum
16
11
16
11
Outdoor Operation Range
Maximum
43
26
43
26
Minimum
16
11
16
11
MODEL
INDOOR
CS-C18JKD
CS-C24JKD
OUTDOOR
CU-C18JKD
CU-C24JKD
7
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
- Patrol Sensor color changes to indicate the dirt level in the air
- Patrol Sensor color changes to indicate the dirt level in the air
• Long Installation Piping
- CS/CU-C18/24JK, long piping up to 25 meter
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
- Blue coated condenser for high resistance to corrosion
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
- Noise prevention during soft dry operation
- Blue coated condenser for high resistance to corrosion
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
8
4 Location of Controls and Components
4.1.
Product Overview
4.1.1.
Indoor Unit
4.1.2.
Outdoor Unit
4.1.3.
Remote Control