10.2. Power Printed Circuit Board
18
10.3. Indicator Printed Circuit Board
10.4. Receiver Printed Circuit Board
10.5. High Voltage Power Supply Printed Circuit Board
19
11 Installation Instruction
11.1. Select the Best Location
11.1.1.
Indoor Unit
• Do not install the unit in excessive oil fume area such as
kitchen, workshop and etc.
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
11.1.2.
Outdoor Unit
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the [piping length for additional gas],
additional refrigerant should be added as shown in the table.
Example: For C18JKD
If the unit is installed at 10 m distance, the quantity of additional 
refrigerant should be 50 g .... (10-7.5) m x 20 g/m = 50 g
11.1.3.
Indoor/Outdoor Unit Installation
Diagram
Model
Horse 
Power 
(HP)
Piping size
Std. 
Length
(m)
Max. 
Ele-
vation 
(m)
Min.
Piping 
Length
(m)
Max.
Piping 
Length
(m)
Addi-
tional 
Refri-
ge-
rant 
(g/m)
Piping 
Length 
for
add. 
gas 
(m)
Gas Liquid
C7JKD
3/4 ~ 
1.5HP
3/8”
1/4”
7.5
5
3
10
10
7.5
C9JKD
5
3
10
10
7.5
C12JKD
1/2”
5
3
15
10
7.5
C18JKD 2.0 ~ 
2.5HP
5
20
3
25
20
7.5
C24JKD
5/8”
20
3
25
30
7.5
20
11.2. Indoor Unit
11.2.1.
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent
it from the vibration.
The centre of installation plate should be at more than   at
right and left of the wall.
The distance from installation plate edge to ceiling should more
than .
From installation plate left edge to unit’s left side is  .
From installation plate right edge to unit’s right is  .
B : For left side piping, piping connection for liquid should be 
about   from this line.
: For left side piping, piping connection for gas should be 
about   from this line.
1. Mount the installation plate on the wall with 5 screws or
more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Putting measuring tape at position as shown in the
diagram above. The hole center is obtained by
measuring the distance namely 128 mm for left and right
hole respectively. Another method is intersection point of
arrow mark extension. The meeting point of the
extension arrow mark is the hole center position.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanting to the outdoor side. (refer
to step 3)
11.2.2.
To Drill a Hole in the Wall and Install 
a Sleeve of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.2.3.
Indoor Unit Installation
Model
Dimension
C7JKD, C9JKD, 
C12JKD
485 mm 82 mm 165 mm 158 mm 43 mm 95 mm
C18JKD, 
C24JKD
585 mm 82 mm 165 mm 158 mm 169 mm 219 mm
When the wall is hollow, please be sure to use the sleeve 
for tube assembly to prevent dangers caused by mice 
biting the connecting cable.