Panasonic CS-C18GKD / CU-C18GKD / CS-C24GKD / CU-C24GKD Service Manual ▷ View online
13
6 Refrigeration Cycle Diagram
14
7 Block Diagram
15
8 Wiring Connection Diagram
8.1.
CS-C18GK CU-C18GK
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CU-C18GK
CONNECTION
CWA951264J
BLUE-GRAY
217
Ω
GRAY-RED
217
Ω
MODEL
CU-C18GK
CONNECTION
2KS314D5AA02
C - R
1.487
Ω
C - S
3.530
Ω
16
8.2.
CS-C24GK CU-C24GK
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CU-C24GK
CONNECTION
CWA951352J
BLUE-YELLOW
99.6
Ω
YELLOW-RED
126.8
Ω
YELLOW-ORANGE
158.7
Ω
MODEL
CU-C24GK
CONNECTION
2JS438D3GA02
C - R
0.830
Ω
C - S
2.257
Ω
Click on the first or last page to see other CS-C18GKD / CU-C18GKD / CS-C24GKD / CU-C24GKD service manuals if exist.