DOWNLOAD Panasonic CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD Service Manual ↓ Size: 3.85 MB | Pages: 72 in PDF or view online for FREE

Model
CS-C18DKD CU-C18DKD CS-C24DKD CU-C24DKD
Pages
72
Size
3.85 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-c18dkd-cu-c18dkd-cs-c24dkd-cu-c24dkd.pdf
Date

Panasonic CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD Service Manual ▷ View online

 • When the vertical airflow direction is set to Manual using the
remote control, the automatic airflow is released and the
airflow direction louver move up and down in the range
shown in the diagram.
 • The louver can be adjusted by pressing the button to the
desired louver position.
 • When stopped with remote control, the discharge vent is
reset, and stop at the closing position.
8.8.1. Auto Control
 • When the horizontal airflow direction is set to Auto using the
remote control, the vanes swings left and right as shown in
the diagram.
 • When stopped with remote control, the discharge vane is
reset, and stop at the reset position.
 • During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that
condition, the vane will stop swinging and rest at 22° angle.
 • When the horizontal airflow direction is set to Manual using
the remote control, the automatic airflow is released and the
airflow direction vane move left and right in the range shown
in the diagram.
The louver can be adjusted by pressing the button to the
desired vane position.
 • When stopped with remote control, the vanes is reset, and
stopped at reset position.
8.7.2. Manual Control
8.8. Horizontal Airflow Direction Control
8.8.2. Manual Control
8.9. Powerful Operation
 • The Powerful operation is to achieve the setting temperature quickly.
 • When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
setting temperature (Lower temperature limit: 16°C).
 • This operation automatically will be running under SHi Fan Speed (Cooling).
 • Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
25
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
 • Powerful operation stops when:-
- Powerful operation has operate for 15 minutes.
- Powerful mode button is pressed again.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode is changed.
8.10. Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
 • The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.
 • Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB(A)
for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present operation sound level.
 • Manual Fan Speed:-
 − RPM control during Lo cool
 − RPM control during Hi & Me cool
 • Auto Fan Speed:-
 • Quiet operation stops when:-
 − Quiet button is pressed again.
 − Stopped by OFF/ON operation button.
 − Timer OFF activates.
 − Powerful button is pressed.
26
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
8.11. Ionizer Operation
 • The Ionizer operation is to provide fresh air effect to user by producing minus ion in discharge air.
8.11.1. Operation Control
 1. Ionizer individual operation
 a. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at the remote control is pressed, the
Ionizer and Fan operations will turn on. Only ION LED will illuminates. Power LED maintain off. (1
→ 2)
 b. Ionizer individual operation can be turned off by pressing the ION button again. (2
→ 1)
 c. Fan speed can be adjusted later by customer during this operation.
 d. Vertical airflow direction can be adjusted using remote control during Ionizer individual operation.
 e. During Ionizer individual operation, operated mode (Auto, Cool, Dry) can be activated by turning on the OFF/ON operation
button. (2
→ 4)
 f. 
If power failure occur during Ionizer individual operation, after power resume, Ionizer operation will be activated immediately.
 g. When the Ionizer circuit feedback process error occur for 24 times (about 11hr 30 min.), Ionizer and Fan operations will turn
off with ION LED blinks continuously.
(For details, please refer to Ionizer Error detection control)
 2. Operation mode & Ionizer operation.
 a. When air-conditioner unit is at “ON” condition and ION operation button at the remote control is pressed, the Ionizer
operation will turn on. ION & Power LED will illuminate. (3
→ 4)
 b. Ionizer operation stops when:
 • ION operation button is press again.
 • Stopped by OFF/ON operation button.
 • Timer OFF activates.
 • Ionizer circuit feedback signal shows error.
 c. Ionizer operation status is not memorised when the air conditioner has been switched off. The air-conditioner will operate
without ionizer operation when it is turned on again. However, if power failure occurs during Ionizer operation together with
Cooling operation, air-conditioner will start to operate at Cooling operation with Ionizer operation when the power is
resumed.
27
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
8.11.2. Error Detection Control
 • The error detection control is to inform user that error occurs at ionizer system and repairing job will be needed.
 • There are two types of error detection control:
a. When Ionizer is ON
 − If ionizer feedback = Lo for 24 times within 11hr 30min, ION LED blinks continuously.
b. When ionizer is OFF
 − If ionizer feedback = Hi, ION LED blinks continuously.
 • During ionizer at breakdown condition, if ionizer feedback voltage = Lo (become normal), ION LED will stop blinking.
 • The error detection control can be reset by:
i) Pressing the OFF/ON operation button to switch the operation OFF.
ii) Pressing the Auto Operation button to force the operation OFF.
iii) Setting the OFF Timer to stop the operation (Not applicable when ionizer is OFF).
8.12. Timer Control
8.12.1. Delay ON Timer
 • When the Delay ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that
the room will reach nearly to the set temperature by the set time.
 • For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
 • For Automatic operation, the indoor fan will operate at SLo speed for 20 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.12.2. Delay OFF Timer
 • When the Delay OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
Notes:
 1. By pressing ON/OFF operation button, the Delay ON Timer or Delay OFF Timer setting will not be cancelled.
 2. To cancel the previous timer setting, press CANCEL button.
 3. To activate the previous timer setting, press SET button.
 4. If main power supply is switched off, the Timer setting will be cancelled.
8.13. Random Auto Restart Control
 • If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
 • It will start with previous operation mode and airflow direction.
 • If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
 • This Random Auto Restart Control is not available when Timer is set.
 • This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.14. Remote Control Signal Receiving Sound
 • Long beep sound will be heard when:-
 − Stopping the air conditioner using ON/OFF switch.
 − Stopping the Quiet Mode.
 − Stopping the Powerful Mode.
 − Stopping the Ion Mode.
 • Short beep sound will be heard for others setting.
28
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
Page of 72
Display

Click on the first or last page to see other CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD service manuals if exist.