8.4.5. Compressor Reverse Rotation Protection Control
 • If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 2.5°C or less for continuous 2 minutes, compressor will stop and restart automatically.
 • Time Delay Safety Control is activated before the compressor restart.
T = Intake air temperature - Indoor heat exchanger temperature
 • This is to prevent compressor from rotate reversely when there is an instantaneous power failure.
8.4.6. Starting Current Control
 • When the compressor, outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will start to
operate at 1.6 second later.
 • The reason of the difference is to reduce the starting current flow.
8.4.7. Anti-Dew Formation Control
 • Purpose is to prevent dew formation on indoor unit air discharge area.
 • When room temperature is constant (±1°C) the following conditions occur for 30 minutes continuously, anti-dew formation will
activate:
 − Remote Control setting temperature is less than 25°C.
 − Compressor is on.
 − Cooling operation mode.
 − Indoor Fan motor operate at Low fan speed or QLo.
 • This control is cancelled immediately when above condition is changed.
 • Anti-Dew formation is control by:
 1. Increasing Air Flow Volume
 a. Lo fan speed
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
 b. QLo fan speed
Dew formation may occurs at QLo cool, therefore QLo cool is operated only 1 hr 30 min (1 hr QLo, 30 min QLo +100
rpm). After that, it operates at QLo +180rpm (However Quiet LED remains on).
21
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
 2. Norrowing
Vertical Airflow Direction
 − During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
 − During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to
10°, 13°, 16°, 19°, 22° under Cooling and Soft Dry operation mode.
 3. Narrowing
Horizontal Airflow Direction
 − During Anti-dew condensation prevention, Airflow Direction Auto-control angle change form o° - 44° to 14° - 30° under
Cooling and Soft Dry operation mode.
 − During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 0°, 11°, 22°, 33°, 44° to
14°, 18°, 22°, 26°, 30° under Cooling and Soft Dry operation mode.
22
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
8.5. Indoor Fan Speed Control
 • Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
SPEED / COOL / DRY
C24DK
C18DK
S Hi
1590
1420
Hi
1530
1360
Me
1390
1250
Lo+
1330
1220
Lo
1250
1150
Lo-
1100
980
S Lo
860
780
Q Hi
1430
1260
Q Me
1290
1150
Q Lo
1150
1050
8.5.2. Automatic Fan Speed Control
 • When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
 − Fan speed rotates in the range of Hi, Me and Lo-.
 − Deodorizing Control will be activated.
 • Auto Fan Speed during Cooling operation:
 1. Indoor fan will rotate alternately between off and on as shown in below diagram.
 2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
 3. For the first time the compressor operate, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the
start of compressor. This cause the room temperture to achieve the setting temperature quickly.
 4. During compressor stop, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher volume of refrigerant
in liquid form returning to the compressor.
 5. After the compressor at turn off condition for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the room.
This is to obtain the actual reading of the intake air temperature.
 6. For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and lesser noise
environment, after 70 seconds from the restart of compressor.
23
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
 • When the vertical airflow direction is set to Auto using the
remote control, the louver swings up and down as shown in
the diagram.
 • When stopped with remote control, the discharge vent is
reset, and stop at the closing position.
 • During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that
condition, the louver will stop swinging and rest at the upper
limit.
 • Auto Fan Speed during Soft Dry operation:
 1. Indoor fan will rotate alternately between off and Lo-.
 2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
 3. When compressor at turn off condition for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room.
This is to obtain the actual reading of intake air temperature.
8.5.3. Manual Fan Speed Control
 • Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
 • There are 3 types of fan speed settings: Lo, Me, Hi.
8.6. Outdoor Fan Speed Control
 • There is only one speed for outdoor fan motor (C18DK).
 • There is 2 speed for outdoor fan motor. Outdoor fan speed can be changed to Hi or Lo according to outdoor temperature
(C24DK).
 • When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
 • Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
8.7. Vertical Airflow Direction Control
8.7.1. Auto Control
24
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD