Panasonic CS-A7GKD / CU-A7GKD / CS-A9GKD / CU-A9GKD / CS-A12GKD / CU-A12GKD Service Manual ▷ View online
21
BOTTOM VIEW
22
10.2. Indoor Unit (Power Printed Circuit Board)
TOP VIEW
BOTTOM VIEW
23
10.3. Indicator
TOP VIEW
BOTTOM VIEW
24
11 Installation Instruction
11.1. Select The Best Location
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the rated length, additional refrigerant
should be added as shown in the table.
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Indoor Unit
Outdoor Unit
Piping size
Rated
Length
(m)
Max
Elevation
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Model
Gas
Liquid
C7GK/
C9GK
C9GK
3/8”
1/4”
7.5
5
10
10
A7GK/
A9GK
A9GK
3/8”
1/4”
7.5
5
10
20
C12GK
1/2”
1/4”
7.5
5
15
10
A12GK
1/2”
1/4”
7.5
5
15
20
Indoor/Outdoor Unit Installation Diagram
Click on the first or last page to see other CS-A7GKD / CU-A7GKD / CS-A9GKD / CU-A9GKD / CS-A12GKD / CU-A12GKD service manuals if exist.