Date

Panasonic CS-A7GKD / CU-A7GKD / CS-A9GKD / CU-A9GKD / CS-A12GKD / CU-A12GKD Service Manual ▷ View online

17
8 Wiring Connection Diagram
8.1.
CS-A7GK CU-A7GK / CS-A9GK CU-A9GK
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-A7GK
CS-A9GK
CONNECTION
CWA921373
BLUE-YELLOW
390.0 
Ω
YELLOW-RED
394.0 
Ω
MODEL
CU-A7GK
CU-A9GK
CONNECTION
CWA951387J
BLUE-YELLOW
287 
Ω
YELLOW-RED
238 
Ω
MODEL
CU-A7GK
CU-A9GK
CONNECTION
2RS122D5BC02
2PS156D3BB02
C - R
5.193 
Ω
3.501 
Ω
C - S
5.557 
Ω
3.405 
Ω
18
8.2.
CS-A12GK CU-A12GK
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-A12GK
CONNECTION
CWA921373
BLUE-YELLOW
390.0 
Ω
YELLOW-RED
394.0 
Ω
MODEL
CU-A12GK
CONNECTION
CWA951117J
BLUE-YELLOW
230 
Ω
YELLOW-RED
255 
Ω
MODEL
CU-A12GK
CONNECTION
2KS206D5AF04
C - R
2.234 
Ω
C - S
2.630 
Ω
19
9 Electronic Circuit Diagram
20
10 Printed Circuit Board
10.1. Indoor Unit (Main Printed Circuit Board)
TOP VIEW
Page of 81
Display