DOWNLOAD Panasonic CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB Service Manual ↓ Size: 17.13 MB | Pages: 127 in PDF or view online for FREE

Model
CS-A24BD CS-A28BD CS-A34BD CS-A43BD CS-A50BD CU-A24BB CU-A28BB CU-A34BB CU-A43BB CU-A50BB CU-C24BB CU-C28BB CU-C34BB CU-C43BB CU-C50BB
Pages
127
Size
17.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-a24bd-cs-a28bd-cs-a34bd-cs-a43bd-cs-a50bd-cu-a2.pdf
Date

Panasonic CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB Service Manual ▷ View online

ELECTRICAL DATA (50Hz)
4.7 CS-A50BD3P / CU-C50BBP8
ITEM / MODEL
Indoor Unit
Outdoor unit
Main Body
CS-A50BD3P
CU-C50BBP8
Cooling Capacity
kW
14.50
(BTU/h)
(49,400)
Refrigerant Charge-less
m
30
Standard Air Volume for High
m
3
/min
Hi 45
Hi 86
Medium and Low Speed
cfm
Hi 1589
3036
External Static Pressure
mmAq
Hi 5 Me 4 Lo 3
-
Pa
Hi 49 Me 39 Lo 29
Air Inlet
Backward Suction
Rear sided Suction
Air Outlet
Front blow-out
Front blow-out
Outside Dimension (H x W x D)
mm
270 x (1500 + 100) x 650
1220 x 1100 x 320
Net Weight
kg (lbs)
56 (123)
116 (256)
Piping
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 19.05 (3/4) Flared Type
Liquid
mm (inch)
O.D Ø 9.52 (3/8) Flared Type
Drain
mm
Female screw RC1 (PT1)
I.DØ 20 x 1
Compressor Type, Number of Set
-
Hermetic-1 (Scroll), 1
Starting Method
-
Direct on-line starting
Motor
Type
-
2-pole 3-phase induction motor
Input
kW
-
Cool/4.56
Rated Output
kW
-
4.1
Fan
Type, Number of Set
Sirocco fan-4
Prop. fan-2
Air Volume Control
Three-Step and Auto mode
-
(Remote Control)
Motor
Type
4-pole single phase induction motor
6-pole single phase induction motor
Input
kW
0.30
0.25
Rated Output
kW
0.20
0.055 x 2
Air-heat exchanger
Louvre-fin type
Louvre-fin type
Refrigerant Control
Capillary tube
-
Refrigerant oil (Charged)
L
-
SONTEX200LT (2.1)
Refrigerant (Charged)
kg (oz)
-
R-22 5.0 (176)
Running
Adjustment
Control Switch
Wired Remote Control
-
Room Temperature
Thermostat (Main Body)
-
Safety Devices
Internal protector for compressor, Internal thermostat for F.M, Crankcase
heater, High pressure switch, Current Transformer
Noise Level (Sound Pressure)
dB (A)
Hi 45 Lo 42
Hi 56
 1. Cooling capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C
D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
MODEL / ITEM
CS-A50BD3P/CU-C50BBP8
Condition by JIS B 8616
Volts
V
380
400
415
Phase
3N
3N
3N
Input Power
kW
Cool
5.10
5.10
5.10
Running Current
A
Cool
8.8
8.8
8.8
Starting Current
A
69
69
69
Power Factor
%
Cool
88
84
81
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Power source
AC, 3N~380V, 400V, 415V 50Hz
21
HIDE AWAY TYPE
5 TECHNICAL DRAWING
CS-A24BD3P, CS-A28BD3P
OUTSIDE DIMENSIONS
22
HIDE AWAY TYPE
CS-A34BD3P, CS-A43BD3P, CS-A50BD3P
OUTSIDE DIMENSIONS
23
HIDE AWAY TYPE
CU-A24BBP5, CU-C24BBP5,
24
HIDE AWAY TYPE
Page of 127
Display

Click on the first or last page to see other CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB service manuals if exist.