 1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
 a. Release the Earth Wire screw. (Fig. 5)
 b. Release the CN-TH connector. (Fig. 5)
 c. Release the CN-ION connector. (Fig. 5)
 d. Release the CN-SONIC connector. (Fig. 5)
 e. Release the CN-STM1 connector. (Fig. 5)
 f. 
Release the CN-STM2 connector. (Fig. 5)
 g. Release the CN-DISP connector. (Fig. 5)
 h. Pull out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
 2. Release the ION connectors. (Fig. 6)
 3. Release the 3 screws. (Fig. 6)
 4. By pressing down the hook at the left, you will be able to
remove the Control Board. (Fig. 6)
 5. Remove the screw at the Cross Flow Fan. (Fig. 7)
 6. Remove the Bearing. (Fig. 8)
 7. Remove the screws at the left of the Evaporator. (Fig. 8)
Fig. 5
Fig. 6
Fig. 7
Fig. 8
12.2. Cross Flow Fan and Indoor Fan Motor Removal Procedures
65
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
 8. Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 9)
REMINDER - To reinstall the Fan Motor, put it back in
place, adjust the position of the Fan Motor’s leadwire
appropriately as shown in the Fig. 7--- before installing the
Cross Flow Fan.
When the batteries are inserted for the first time or the batteries
are replaced, all the indications will blink and the remote control
might not work.
If this happen, remove the cover of the remote control and you
will find a resetting terminal, and by shorting it with a minus
screwdriver, it will return to normal.
Fig. 9
12.3. Remote Control Reset
66
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
12.4. Auto OFF/ON Button
 • The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or
malfunctioning.
 • Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then
release the button.
 • User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
 • To enter various setting mode:
 − Press the “Auto OFF/ON Button” continuosly for 5s (beep sound is heard) and release.
 − Within 20s, press the “Auto OFF/ON Button” continuously for 5s again (2 beep sound is heard) and release.
 − Various setting mode has limit up to 20s. Then return to normal operation.
12.4.1. Toggle Remote Control Signal Receiving Sound
 • Under various setting mode, press the “Auto OFF/ON Button” to toggle the remote control sound.
 − Short “beep” : Turn ON remote control signal receiving sound.
 − Long “beep” : Turn OFF remote control signal receiving sound.
 • After “Auto OFF/ON Button” is pressed, the 20s counter for various setting mode is restarted.
12.4.2. Select Remote Control Transmission Code
 • There are 4 type of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal inteference
when there are 2 or more indoor unit installed nearby together.
 • To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
Remote Control Printed Circuit Board
Transmission Code Combination
J-A
J-B
Remote Control No.
* Short
Open
Short
Open
Open
Open
Short
Short
A (default)
B
C
D
 • Under various setting mode, after select the transmission code combination of remote control, press any button of remote
control to transmit a signal to indoor unit. The transmission code will be stored in EEPROM.
 • After signal is received, the various setting mode is cancelled and return to normal operation.
67
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
13.1. Refrigeration cycle system
In order to diagnose malfunctions, make sure that there are no
electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the
refrigeration cycle depends on various conditions, the standard
values for them are shown in the table on the right.
-
13 Troubleshooting Guide