– 11 –
CS-A120TE
Refrigeration Cycle Diagram
CS-A120T
CS-A180T/CS-240T
Model
A120T
A180T
A240T
GAS
1/2"
1/2"
5/8"
LIQUID
1/4"
1/4"
1/4"
Pipe Size
Max. Piping
Length
(m)
12
15
15
Max.
Elevation
(m)
5
8
8
Untitled-10
6/19/00, 6:38 PM
11
– 12  –
CS-A120TE
Block Diagram
CS-A120T/CU-A120T
Untitled-10
6/19/00, 6:38 PM
12
– 13 –
CS-A120TE
Block Diagram
CS-A180T/CU-A180T
CS-A240T/CU-A240T
Untitled-10
6/19/00, 6:38 PM
13
– 14  –
CS-A120TE
CS-A120T/CU-A120T
CONNECTION
BLUE - YELLOW
YELLOW - BROWN
BROWN - ORANGE
RED - ORANGE
CWA92138(
)
282.3
40.4
52.7
278.4
CONNECTION
C-R
C-S
2KS224D5AA02(
)
2.45
3.86
Wiring Diagram
Resistance of Indoor Fan Motor
Windings.
NOTE:
B
: BLUE
BL
: BLACK
BR
: BROWN
GR
: GRAY
O
: ORANGE
P
: PINK
PU
: PURPLE
R
: RED
W
: WHITE
Y
: YELLOW
Y/G
: YELLOW/GREEN
CONNECTION
BLUE - YELLOW
YELLOW - RED
CWA95244(
)
312.9
419.5
Resistance of Outdoor Fan Motor
Windings.
Resistance of Comp Windings.
* Resistance at 20
°
C of Ambient temp.
Untitled-10
6/19/00, 6:38 PM
14
Page of 30