LG WT-W7111TH Service Manual ▷ View online

32
12-2.Defects on displaying function
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Main voltage
1. Measure mains voltage at the wall 
outlet
2.  Meaure voltage at the extended 
outlet that the washer is plugged in 
if the extended outlet is used and 
voltage at the electrical outlet
is normal in the above.
Controller
1. Defect of LED.
2. Defect of LED driving circuit.
3. Defect of micom.
Less than 85%
of the rating.
Less than 85%
of the rating
Low voltage. 
The dia of the lead 
wire is smaller or 
many loads are 
connected at the 
same outlet
Defect of controller.
To explain that it is 
caused by low voltage in 
electric supply and
recommend using a 
transfomer if voltage has
been continuously low.
To use a transfomer 
having a enough
capacity if using 
a transfomer.
Change the controller.
12-3.Reset During operation
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Mains Voltage
1. Measure voltage of the outlet that the 
washer is plugged into during wash and 
spin.
2. Reset symptom happens at specific 
time zone repeatedly.
3. Check whether a transfomerlent
power cut happens.
(Fluorescent lamp is 
transfomeriently blinked.)
Less than 
80% of the rating.
Mains voltage is too
low or size of a lead
wire is too small.
External noise 
inrushed.
Explain that it is caused 
by low voltage in electric 
mains and recommend
using a suitable size of
leads.
Explain it is caused by 
using environment.
(It happens when 
equipment with high 
frequency is used 
around)
Explain it is a problem of 
electric supply 
environment.
33
12-4. Water doesn’t come into the wash tub.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Inlet Valve
1. If water doesn’t come though the 
inlet valve works(electric sound 
occurs)
1) Check whether water mains is cut.
2) Check whether tabs are turned on.
3) Hot & cold tab are opposite
connected.
4) Wrongly select water temperature
option.
5) If there are no problems in the 
above, check the inlet valve filters 
after disconnecting the water supply
hoses.
6) If there are no problems in the 
above a diaphragm hole in the valve
is blocked  by foreign substance or 
the plunger in it is locked.
2. If the inlet valve doesn’t work(there 
is no electric sound)during filling 
cycle.
1) Check whether it’s connectors are 
taken off or they have poor 
connection. 
2) Check resistance of the inlet valve.
Water mains cut.
Don’t tumed on.
Connected
opposite.
Selected 
opposite.
Filters blocked
by foreign
substance.
A connector is
taken off.
Mains cut. 
Mistake of use.
Wrong installation.
Mistake of use.
Don’t clean.
Defect of the
inlet valve.
Defect of contact.
Coil is open
Explain.
Turn on the tap.
Correct their locations
and turn on the tap.
Explain how to use. 
Clean them by brush 
and explain cleaning 
regulary them.
Change the inlet valve.
Reconnect it or remove
the causes to make poor 
connection.
Change the inlet valve.
12-3.Reset During operation
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Controller
1. If mains voltage and the drain motor 
have no defects a defect of the 
controller is highly possible.
Change the controller.
34
12-5. Water fills continuously or intermittently.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Wrong Installation/Leakage
1. Check whether the drain hose is 
laying down on the floor. 
(For pump model)
2. Check where water leaks.
Pressure Switch
1. Check the pulsator is rotating when 
water fills continuously.
2. If there is no defect in the pressure 
swith, check whether the air hole of 
the outer tub is blocked.
Inlet Valve
1. Does water fills even though it is not
energized (power is off)?
Controller
1. Does water fill immediately after the
power switch turns on before pushing 
the start/pause button.
Drain hose 
laying down.
Water leaks 
from a part.
It doesn’t 
rotate.
Blocked.
Water fills.
Wrong installation. 
Defect of the part.
Water pressure is
not sensed.
Air hole blocked.
Defect of the inlet
valve.
Short circuit of the 
triac of the 
controller.
The drain hose 
should be hung on the 
stand-pipe or the tub.
Change the part.
Repair it.
Check the tube of the  
pressure swith,if it is bent
or blocked, repair that.
Repair the blocked hole.
Change the inlet valve.
Change the controller.
12-4. Water doesn’t come into the wash bowl.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Pressure Switch
1. Is there PE error on the display 
which means pressure switch error
2. Check frequency of the pressure 
switch without load if wash is 
proceeding without filling.
Controller
1. Defect of controller is highly possible
if inlet valve and pressure switch have
no defects in the above.
Reconnect the connector
or change leads. Change
the pressure switch if coil
is open. 
Change the pressure
switch.
Change the controller.
PE Error 
displayed. 
Less then 
26.2
Connector is taken
off, or lead or coil is
open.
Defect of the 
pressure switch.
35
12-6. Display “LE” message and doesn’t work
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
1. In initial state display “LE” message.
1) Measure voltage of hall sensor   
asm.
2) Check resistance of the motor.
Gray-White
DC 15V
OV
Gray-Red
-Blue
DC 12V
OV
Normal
Resistance 
No defect
Poor
No defect
Poor
Motor coil is
open.
Contact lefect of
the leack
Change the PCB Asm
Change the PCB Asm
Change the motor
Remove the cause
WH
Hall
sensor asm
DC 15V
In PCB asm
Gray (Ground)
BL
RD
Page of 44