DOWNLOAD LG WT-W7111TH Service Manual ↓ Size: 2.56 MB | Pages: 44 in PDF or view online for FREE

Model
WT-W7111TH
Pages
44
Size
2.56 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wt-w7111th.pdf
Date

LG WT-W7111TH Service Manual ▷ View online

Hall Sensor
Stator Housing
Water Guide
For assembly take care lead wire’s state,
it produce a noise and cut attach the rotor.
10-5.  Replacement of Hall Sensor
Assembly.
Deposit the stator assembly on the floor Be seue
that the terminal directions is upper.
Insert”___” driver to gap “A” between hook and hall
sensor asssembly, and then lift and pull the hall
sensor assembly out as shown in the figure.
When assembling new hall sensor, push and insert
hall sensor along three guide pins perfectly.
Must check terminal connection after replacement.
10-6.  Replacement of bearing housing asm
Loosen 14 Fixing screws on the Bearing Housing
ASM and pull up it.
24
Fig.13
Fig.14
Fig.15
Fig.16
While disassembling hall
sensor, refrain from damage on
stator coil.
Caution
!
A
10-7.  Replacement of Outcase and 
Suspension Asm
Open the back cover on the back of machine and
disassemble all lead wires.
(Pull out the pressure switch tube and connector
housing.)
Separate top cover from washing machine.
As in Fig.19, lift snubber bar and take it out of 
out case with out tub.
Suspension assembly shall not be disassembled.
Replace damper as assembly. (K100)
(P/No.: 4902EA2001A)
Disassembled the anti-rat base assembly.
25
Fig.17
Fig.18
Fig.19
Fig.20
26
10-8.  Disassembly of Inlet Valve ASM and
D.T Housing ASM
1. Open lid assembly and disassemble detergent box.
2. Disassemble back panel(joined control panel)from 
top cover.
3. Remove two inlet valve screws and pull up inlet
valve from D.T housing 
Be careful that the silicon rubber of D.T housing for
sealing is not missing.
4. Inlet valve assembly is disassembled by pulling out
the lead wire attached on inlet valve assembly,
as in.
5. To disassemble D.T housing assembly, loosen the
screw tightened with the top cover and then pull the
assembly back slopped down.
Fig.21
Fig.22
Fig.23
27
10-9. Replacement of Drain pump.
Check water is remained before the drain pump
servicing. 
1. Be sure to unplug the power.
2. Loosen the 4 screw on the back side and 
disassemble back cover from the machine. 
3. Disconnect the pump lead wire housing.
4. Loosen the 3 screw from the lower plate and
disassemble the drain pump.
5. Change the drain pump asm, assemble it
tighten the screw.
6. Assemble the back cover.
Fig.24
Fig.25
Fig.26
Page of 44